14 research outputs found
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluatio
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluatio
Guillain-Barre syndrome after SARS-CoV-2 infection in an international prospective cohort study
In the wake of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, an increasing number of patients with neurological disorders, including Guillain-Barre syndrome (GBS), have been reported following this infection. It remains unclear, however, if these cases are coincidental or not, as most publications were case reports or small regional retrospective cohort studies.
The International GBS Outcome Study is an ongoing prospective observational cohort study enrolling patients with GBS within 2 weeks from onset of weakness. Data from patients included in this study, between 30 January 2020 and 30 May 2020, were used to investigate clinical and laboratory signs of a preceding or concurrent SARS-CoV-2 infection and to describe the associated clinical phenotype and disease course. Patients were classified according to the SARS-CoV-2 case definitions of the European Centre for Disease Prevention and Control and laboratory recommendations of the World Health Organization.
Forty-nine patients with GBS were included, of whom eight (16%) had a confirmed and three (6%) a probable SARS-CoV-2 infection. Nine of these 11 patients had no serological evidence of other recent preceding infections associated with GBS, whereas two had serological evidence of a recent Campylobacter jejuni infection. Patients with a confirmed or probable SARS-CoV-2 infection frequently had a sensorimotor variant 8/11 (73%) and facial palsy 7/11 (64%). The eight patients who underwent electrophysiological examination all had a demyelinating subtype, which was more prevalent than the other patients included in the same time window [14/30 (47%), P = 0.012] as well as historical region and age-matched control subjects included in the International GBS Outcome Study before the pandemic [23/44 (52%), P = 0.016]. The median time from the onset of infection to neurological symptoms was 16 days (interquartile range 12-22).
Patients with SARS-CoV-2 infection shared uniform neurological features, similar to those previously described in other post-viral GBS patients. The frequency (22%) of a preceding SARS-CoV-2 infection in our study population was higher than estimates of the contemporaneous background prevalence of SARS-CoV-2, which may be a result of recruitment bias during the pandemic, but could also indicate that GBS may rarely follow a recent SARS-CoV-2 infection. Consistent with previous studies, we found no increase in patient recruitment during the pandemic for our ongoing International GBS Outcome Study compared to previous years, making a strong relationship of GBS with SARS-CoV-2 unlikely. A case-control study is required to determine if there is a causative link or not
Paroxysmal painful tonic spasms in neuromyelitis optica spectrum disorder
Background: Recently, an association between painful tonic spasms (PTS) and Neuromyelitis Optica Spectrum Disorder (NMOSD) was established. Objective: To describe the clinical characteristics of PTS in NMOSD based on a video recording and to provide a literature review on the topic. Methods: We report a case of a 38 years-old woman with a diagnosis of NMOSD and positive aquaporin-4 IgG antibody status who developed PTS five weeks after an episode of longitudinal extensive transverse myelitis (LETM). Results: Repetitive, brief, and painful episodes of muscle contraction were observed on the patient's left hand, spreading to the left arm, and then extending to the four limbs. While pregabalin and topiramate had no influence on these episodes, the patient responded to carbamazepine (CBZ), without symptom recurrence after one year. Conclusions: PTS in association with LETM can be considered typical for NMOSD. Although the exact mechanism is unknown, ephaptic transmission after spinal cord damage and excitatory soluble factors released during acute inflammation responses are sought to be involved. Symptomatic treatment with CBZ achieved remission of spams in our case
Limbic encephalitis associated with systemic sclerosis
We report the case of a patient affected by systemic sclerosis (SSc) who developed autoimmune limbic encephalitis, which improved under immunosuppressant agents and high-dose intravenous immunoglobulins. In our patient the autoimmune encephalitis occurred during apparently quiescent SSc, though concomitantly with novel arthritis. Moreover, our patient showed auto-antibodies directed against SSA antigen but the panel of auto-antibodies associated with autoimmune encephalitis was negative. We discuss the potential for immunopathogenic inflammatory events affecting the central nervous system in SSc then favoring the occurrence of autoimmune encephalitic disorders. The possibility of a "neuro-scleroderma" may have important consequences in terms of therapeutic approaches
Continuous Intraoperative Monitoring of Temporal Lobe Epilepsy Surgery.
BACKGROUND/AIMS
The monitoring of interictal epileptiform discharge rates (IEDRs) all along anterior temporal lobe resections (ATLRs) has never been reported. Here the effect of ATLR on continuous IEDR monitoring is described.
METHODS
IEDRs computed automatically during entire interventions were recorded in 34 patients (38.2%, 13/34 depth; 61.8%, 21/34 scalp electrodes only). Monitorings were invalidated when burst suppression occurred or if initial IEDRs were <5.
RESULTS
Monitoring was successful for 69.2% (9/13) of the patients with depth recordings and for 4.8% (1/21) of the patients with scalp recordings. Burst suppressions precluded it in 30.8% (4/13) of the depth and in 57.1% (12/21) of the scalp recordings. Initial IEDRs were <5 for 38.1% (8/21) of the scalp recordings. Significant IEDR decreases were observed in 8/10 patients with successful monitoring. These decreases started with resection of the superior temporal gyrus. IEDRs decreased further with amygdalohippocampectomy in 3/5 patients. At the 12-month follow-up, all patients with IEDR decreases remained seizure free; both patients without did not.
CONCLUSION
IEDR monitoring was possible with depth, but not with scalp electrodes. IEDR decreases started with resection of the superior temporal gyrus. A larger patient cohort is necessary to confirm the high predictive values of IEDR monitoring that could become a tool for surgery customization