2 research outputs found

    Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation

    Get PDF
    Abstract Pedicle screw fixation has achieved significant popularity amongst spinal surgeons for both single and multi-level spinal fusion. Misplacement and pedicle cortical violation occurs in over 20% of screw placement and can result in potential complications such as dysthesia, paraparesis or paraplegia. There have been many advances in techniques available for navigating through the pedicle; however, these techniques are not without drawbacks. A new electrical conductivity-measuring device, previously evaluated on the porcine model to detect the pedicle violation, was evaluated amongst nine European Hospitals to be used in conjunction with the methods currently used in that centre. This new device is based on two original principles; the device is integrated in the drilling or screwing tool. The technology allows real-time detection of perforation through two independent parameters, impedance variation and evoked muscle contractions. Data was collected twofold. Initially, the surgeon was given the device and a comparison was made between the devices ability to detect a breech and the surgeon's ability to detect one using his traditional methods of pedicle preparation. In the second module of the study, the surgeon was limited to using the electrical conductivity detection device as their sole guide to detect pedicle breaches. A comparison was made between the detection ability of the device and the other detection possibilities. Post-operative fine cut CT scanning was used to detect the pedicle breaches. Overall, the 11 trial surgeons performed a total of 521 pedicle drillings on 97 patients. Initially there were 147 drillings with 23 breaches detected. The detection rate of these breaches were 22/23 for the device compared to 10/23 by the surgeon. Over both parts of the study 64 breaches (12.3%) were confirmed on post-operative CT imaging. The electrical conductivity detection device detected 63 of the 64 breaches (98.4%). There was one false negative and four false positives. This gives the device an overall sensitivity of 98% and specificity of 99% for detecting a pedicle breach. The negative predictive value was 99.8%, with a positive predictive value of 94%. No adverse event was noted with the use of the electrical conductivity device. Electrical conductivity monitoring may provide

    Molecular MR imaging for the evaluation of the effect of dynamic stabilization on lumbar intervertebral discs

    No full text
    Abstract The dynamic stabilization of lumbar spine is a non-fusion stabilization system that unloads the disc without the complete loss of motion at the treated motion segment. Clinical outcomes are promising but still not definitive, and the long-term effect on instrumented and adjacent levels is still a matter of discussion. Several experiments have been devised in order to gain a better understanding of the effect of the device on the intervertebral disc. One of the hypotheses was that while instrumented levels are partially relieved from loading, adjacent levels suffer from the increased stress. But this has not been proved yet. The aim of this study was to investigate the long-term effect of dynamic stabilization in vivo, through the quantification of glycosaminoglycans (GAG) concentration within instrumented and adjacent levels by means of the delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage (dGEMRIC) protocol. Ten patients with low back pain, unresponsive to conservative treatment and scheduled for Dynesys implantation at one to three lumbar spine levels, underwent the dGEMRIC protocol to quantify GAG concentration before and 6 months after surgery. Each patient was also evaluated with visual analog scale (VAS), Oswestry, Prolo, Modic and Pfirrmann scales, both at pre-surgery and at follow-up. Six months after implantation, VAS, Prolo and Oswestry scales had improved in all patients. Pfirrmann scale could not detect any change, while dGEMRIC data already showed a general improvement in the instrumented levels: GAG was increased in 61% of the instrumented levels, while 68% of the non-instrumented levels showed a decrease in GAG, mainly in the posterior disc portion. In particular, seriously GAG-depleted discs seemed to have the greatest benefit from the Dynesys implantation, whereas less degenerated discs underwent a GAG depletion. dGEMRIC was able to visualize changes in both instrumented and non-instrumented levels. Our results suggest that the dynamic stabilization of lumbar spine is able to stop and partially reverse the disc degeneration, especially in seriously degenerated discs, while incrementing the stress on the adjacent levels, where it induces a matrix suffering and an early degeneration
    corecore