6,271 research outputs found
Implementation and performance of the Detector Control System for the electromagnetic calorimeter of the CMS experiment
In this presentation we describe the main design objectives, the detailed specifications and the final layout of the Detector Control System (DCS) for the electromagnetic calorimeter (ECAL) of the CMS experiment. Emphasis is put on the system implementation and specific hardware and software solutions in each of its sub-systems. The latest results from the tests of final prototypes of these subsystems during the 2006 ECAL test-beam programme, as well as the installation and commissioning of the whole DCS at the CMS experimental construction site are discussed
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
Determination of the b quark mass at the M_Z scale with the DELPHI detector at LEP
An experimental study of the normalized three-jet rate of b quark events with
respect to light quarks events (light= \ell \equiv u,d,s) has been performed
using the CAMBRIDGE and DURHAM jet algorithms. The data used were collected by
the DELPHI experiment at LEP on the Z peak from 1994 to 2000. The results are
found to agree with theoretical predictions treating mass corrections at
next-to-leading order. Measurements of the b quark mass have also been
performed for both the b pole mass: M_b and the b running mass: m_b(M_Z). Data
are found to be better described when using the running mass. The measurement
yields: m_b(M_Z) = 2.85 +/- 0.18 (stat) +/- 0.13 (exp) +/- 0.19 (had) +/- 0.12
(theo) GeV/c^2 for the CAMBRIDGE algorithm. This result is the most precise
measurement of the b mass derived from a high energy process. When compared to
other b mass determinations by experiments at lower energy scales, this value
agrees with the prediction of Quantum Chromodynamics for the energy evolution
of the running mass. The mass measurement is equivalent to a test of the
flavour independence of the strong coupling constant with an accuracy of 7
permil.Comment: 24 pages, 10 figures, Accepted by Eur. Phys. J.
Detector Control System for the Electromagnetic Calorimeter of the CMS experiment
The Compact Muon Solenoid (CMS) is one of the general purpose particle detectors at the Large Hadron Collider (LHC) at CERN. The challenging constraints on the design of one of its sub-detectors, the Electromagnetic Calorimeter (ECAL), required the development of a complex Detector Control System (DCS). In this paper the general features of the CMS ECAL DCS during the period of commissioning and cosmic running will be presented. The feedback from the people involved was used for several upgrades of the system in order to achieve a robust, flexible and stable control system. A description of the newly implemented features for the CMS ECAL DCS subsystems will be given as well
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated
Recommended from our members
Recent Advances in Developing Platinum Monolayer Electrocatalysts for the O2 Reduction Reaction
For Pt, the best single-element catalyst for many reactions, the question of content and loading is exceedingly important because of its price and availability. Using platinum as a fuel-cell catalyst in automotive applications will cause an unquantifiable increase in the demand for this metal. This big obstacle for using fuel cells in electric cars must be solved by decreasing the content of Pt, which is a great challenge of electrocatalysis Over the last several years we inaugurated a new class of electrocatalysts for the oxygen reduction reaction (ORR) based on a monolayer of Pt deposited on metal or alloy carbon-supported nanoparticles. The possibility of decreasing the Pt content in the ORR catalysts down to a monolayer level has a considerable importance because this reaction requires high loadings due to its slow kinetics. The Pt-monolayer approach has several unique features and some of them are: high Pt utilization, enhanced (or decreased) activity, enhanced stability, and direct activity correlations. The synthesis of Pt monolayer (ML) electrocatalysts was facilitated by our new synthesis method which allowed us to deposit a monolayer of Pt on various metals, or alloy nanoparticles [1, 2] for the cathode electrocatalyst. In this synthesis approach Pt is laid down by the galvanically displacing a Cu monolayer, which was deposited at underpotentials in a monolayer-limited reaction on appropriate metal substrate, with Pt after immersing the electrode in a K{sub 2}PtCl{sub 4} solution
Measurement and Interpretation of Fermion-Pair Production at LEP energies above the Z Resonance
This paper presents DELPHI measurements and interpretations of
cross-sections, forward-backward asymmetries, and angular distributions, for
the e+e- -> ffbar process for centre-of-mass energies above the Z resonance,
from sqrt(s) ~ 130 - 207 GeV at the LEP collider. The measurements are
consistent with the predictions of the Standard Model and are used to study a
variety of models including the S-Matrix ansatz for e+e- -> ffbar scattering
and several models which include physics beyond the Standard Model: the
exchange of Z' bosons, contact interactions between fermions, the exchange of
gravitons in large extra dimensions and the exchange of sneutrino in R-parity
violating supersymmetry.Comment: 79 pages, 16 figures, Accepted by Eur. Phys. J.
A Determination of the Centre-of-Mass Energy at LEP2 using Radiative 2-fermion Events
Using e+e- -> mu+mu-(gamma) and e+e- -> qqbar(gamma) events radiative to the
Z pole, DELPHI has determined the centre-of-mass energy, sqrt{s}, using energy
and momentum constraint methods. The results are expressed as deviations from
the nominal LEP centre-of-mass energy, measured using other techniques. The
results are found to be compatible with the LEP Energy Working Group estimates
for a combination of the 1997 to 2000 data sets.Comment: 20 pages, 6 figures, Accepted by Eur. Phys. J.
Study of Inclusive J/psi Production in Two-Photon Collisions at LEP II with the DELPHI Detector
Inclusive J/psi production in photon-photon collisions has been observed at
LEP II beam energies. A clear signal from the reaction gamma gamma -> J/psi+X
is seen. The number of observed N(J/psi -> mu+mu-) events is 36 +/- 7 for an
integrated luminosity of 617 pb^{-1}, yielding a cross-section of
sigma(J/psi+X) = 45 +/- 9 (stat) +/- 17 (syst) pb. Based on a study of the
event shapes of different types of gamma gamma processes in the PYTHIA program,
we conclude that (74 +/- 22)% of the observed J/psi events are due to
`resolved' photons, the dominant contribution of which is most probably due to
the gluon content of the photon.Comment: 13 pages, 8 figures, Accepted by Phys. Lett.
A Measurement of the Tau Hadronic Branching Ratios
The exclusive and semi-exclusive branching ratios of the tau lepton hadronic
decay modes (h- v_t, h- pi0 v_t, h- pi0 pi0 v_t, h- \geq 2pi0 v_t, h- \geq 3pi0
v_t, 2h- h+ v_t, 2h- h+ pi0 v_t, 2h- h+ \geq 2pi0 v_t, 3h- 2h+ v_t and 3h- 2h+
\geq 1pi0 v_t) were measured with data from the DELPHI detector at LEP.Comment: 53 pages, 18 figures, Accepted by Eur. Phys. J.
- …