    Sex-specific aortic valve calcifications in patients undergoing transcatheter aortic valve implantation

    Get PDF
    To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th–75th percentile 77.5–85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th–75th percentile 76.5–84.5) vs. 82.4 (78.2–85.9), P ≤ 0.01] and had a larger annulus area [512 mm 2 (25th–75th percentile 463–570) vs. 405 mm 2 (365–454), P < 0.01] and higher Agatston score [2567 (25th–75th percentile 1657–3913) vs. 1615 (25th–75th percentile 905–2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women

    Sequential Alcohol Septal Ablation to Resolve LV Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement

    Get PDF
    Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography–derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation can mitigate neo-LVOTO risk. We report a case of sequential alcohol septal ablation of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.</p

    Rationale and design of SAVI-AoS:A physiologic study of patients with symptomatic moderate aortic valve stenosis and preserved left ventricular ejection fraction

    Get PDF
    Background: Moderate aortic valve stenosis occurs twice as often as severe aortic stenosis (AS) and carries a similarly poor prognosis. Current European and American guidelines offer limited insight into moderate AS (MAS) patients with unexplained symptoms. Measuring valve physiology at rest while most patients experience symptoms during exertion might represent a conceptual limitation in the current grading of AS severity. The stress aortic valve index (SAVI) may delineate hemodynamically significant AS among patients with MAS. Objectives: To investigate the diagnostic value of SAVI in symptomatic MAS patients with normal left ventricular ejection fraction (LVEF ≥ 50%): aortic valve area (AVA) > 1 cm2 plus either mean valve gradient (MG) 15–39 mmHg or maximal aortic valve velocity (AOV max) 2.5–3.9 m/s. Short-term objectives include associations with symptom burden, functional capacity, and cardiac biomarkers. Long-term objectives include clinical outcomes. Methods and results: Multicenter, non-blinded, observational cohort. AS severity will be graded invasively (aortic valve pressure measurements with dobutamine stress testing for SAVI) and non-invasively (echocardiography during dobutamine and exercise stress). Computed tomography (CT) of the aortic valve will be scored for calcium, and hemodynamics simulated using computational fluid dynamics. Cardiac biomarkers and functional parameters will be serially monitored. The primary objective is to see how SAVI and conventional measures (MG, AVA and Vmax) correlate with clinical parameters (quality of life survey, 6-minute walk test [6MWT], and biomarkers). Conclusions: The SAVI-AoS study will extensively evaluate patients with unexplained, symptomatic MAS to determine any added value of SAVI versus traditional, resting valve parameters

    Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.

    Get PDF
    BACKGROUND New permanent pacemaker implantation (new-PPI) remains a compelling issue after Transcatheter Aortic Valve Replacement (TAVR). Previous studies reported the relationship between a short MS length and the new-PPI post-TAVR with a self-expanding THV. However, this relationship has not been investigated in different currently available THV. Therefore, the aim of this study was to investigate the association between membranous septum (MS)-length and new-PPI after TAVR with different Transcatheter Heart Valve (THV)-platforms. METHODS We included patients with a successful TAVR-procedure and an analyzable pre-procedural multi-slice computed tomography. MS-length was measured using a standardized methodology. The primary endpoint was the need for new-PPI within 30 days after TAVR. RESULTS In total, 1811 patients were enrolled (median age 81.9 years [IQR 77.2-85.4], 54% male). PPI was required in 275 patients (15.2%) and included respectively 14.2%, 20.7% and 6.3% for Sapien3, Evolut and ACURATE-THV(p ​< ​0.01). Median MS-length was significantly shorter in patients with a new-PPI (3.7 ​mm [IQR 2.2-5.1] vs. 4.1 ​mm [IQR 2.8-6.0], p ​= ​<0.01). Shorter MS-length was a predictor for PPI in patients receiving a Sapien3 (OR 0.87 [95% CI 0.79-0.96], p ​= ​<0.01) and an Evolut-THV (OR 0.91 [95% CI 0.84-0.98], p ​= ​0.03), but not for an ACURATE-THV (OR 0.99 [95% CI 0.79-1.21], p ​= ​0.91). By multivariable analysis, first-degree atrioventricular-block (OR 2.01 [95% CI 1.35-3.00], p = <0.01), right bundle branch block (OR 8.33 [95% CI 5.21-13.33], p = <0.01), short MS-length (OR 0.89 [95% CI 0.83-0.97], p ​< ​0.01), annulus area (OR 1.003 [95% CI 1.001-1.005], p ​= ​0.04), NCC implantation depth (OR 1.13 [95% CI 1.07-1.19] and use of Evolut-THV(OR 1.54 [95% CI 1.03-2.27], p ​= ​0.04) were associated with new-PPI. CONCLUSION MS length was an independent predictor for PPI across different THV platforms, except for the ACURATE-THV. Based on our study observations within the total cohort, we identified 3 risk groups by MS length: MS length ≤3 ​mm defined a high-risk group for PPI (>20%), MS length 3-7 ​mm intermediate risk for PPI (10-20%) and MS length > 7 ​mm defined a low risk for PPI (<10%). Anatomy-tailored-THV-selection may mitigate the need for new-PPI in patients undergoing TAVR

    Impact of different guidewires on the implantation depth using the largest self-expandable TAVI device

    Get PDF
    BackgroundThe deployment process of the largest self-expandable device (STHV-34) during transcatheter aortic valve implantation (TAVI) might be challenging due to stabilization issues. Whether the use of different TAVI-guidewires impact the procedural success and outcome is not well-known. Therefore, we sought to evaluate the impact of non-Lunderquist (NLu) vs. the Lunderquist (Lu) guidewires during TAVI using the STHV-34 on the procedural and 30-day outcomes.MethodsThe primary study endpoint was defined as the final implantation depth (ID) depending on the selected guidewire strategy. Key secondary endpoints included VARC-3-defined complications.ResultsThe study cohort included 398 patients of four tertiary care institutions, of whom 79.6% (317/398) had undergone TAVI using NLu and 20.4% (81/398) using Lu guidewires. Baseline characteristics did not substantially differ between NLu and Lu patients. The average ID was higher in the Lu cohort (NLu vs. Lu: −5.2 [−7.0–(−3.5)] vs. −4.5 [−6.0–(−3.0)]; p = 0.022*). The optimal ID was reached in 45.0% of patients according to former and only in 20.1% according to nowadays best practice recommendations. There was no impact of the guidewire use on the 30-day outcomes, including conduction disturbances and pacemaker need (NLu vs. Lu: 15.1 vs. 18.5%; p = 0.706).ConclusionThe use of the LunderquistTM guidewire was associated with a higher ID during TAVI with the STHV-34 without measurable benefits in the 30-day course concerning conduction disturbances and associated pacemaker need. Whether using different guidewires might impact the outcome in challenging anatomies should be further investigated in randomized studies under standardized conditions

    Moderate Aortic Stenosis—Advanced Imaging, Risk Assessment, and Treatment Strategies

    Get PDF
    Moderate aortic stenosis is increasingly recognized as a disease entity with poor prognosis. Diagnosis of moderate aortic stenosis may be complemented by laboratory tests and advanced imaging techniques focused at detecting signs of cardiac damage such as increase of cardiac enzymes (N-terminal pro-B-type Natriuretic Peptide, troponin), left ventricular remodeling (hypertrophy, reduced left ventricular ejection fraction), or myocardial fibrosis. Therapy should include guideline-directed optimal medical therapy for heart failure. Patients with signs of cardiac damage may benefit from early intervention, which is the focus of several ongoing randomized controlled trials. As yet, no evidence-based therapy exists to halt the progression of aortic valve calcification

    Comparative analysis of different risk prediction tools after mitral Transcatheter edge-to-edge repair

    Get PDF
    Background: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. Methods: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. Results: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. Conclusion: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.</p