13 research outputs found

    Computed tomography angiography-guided recanalization of saphenous vein graft chronic total occlusion

    Get PDF
    Computed tomography (CT) angiography can augment conventional coronary angiography relative to length of vessel occlusion and quality of distal run-off. In this case report we describe the significance of CT angiography in the revascularization decision-making process of a patient following occlusion of both coronary artery bypass grafts

    Long-Term Positive Remodeling of the Right Coronary Artery after Reimplantation from the Pulmonary Artery to the Ascending Aorta

    No full text
    A 53-year-old woman, nonsmoking patient, with a history of surgically corrected anomalous origin of the right coronary artery from the pulmonary artery 17 years prior to admission, presented to our department complaining of mild, left-sided exertional chest pain for the past 3 months. She underwent a computed tomography examination of the heart and coronary angiography revealing postsurgical changes to the coronary vasculature and severe stenosis of the left circumflex artery, which was successfully treated by percutaneous stent implantation

    Clinical Question Influence on Radiation Dose of Cardiac CT Scan in Children

    No full text
    Background: To assess the impact of different clinical questions on radiation doses acquired during cardiac computed tomography in children. Methods: A total of 116 children who underwent cardiac CT on a third-generation dual-source CT scanner were included. The clinical questions were divided into three main categories: the extent of scanning in the z-axis, coronary artery assessment and cardiac function assessment. Radiation dose values represented as a dose-length product (DLP) in mGy*cm were recorded from the CT scanner protocols. Results: There were significantly higher doses in cases with cardiac function assessment (median DLP 348 versus 59 mGy*cm, p p < 0.01). Conclusion: The most important factor was the assessment of cardiac function, where the median radiation dose was 4.3× higher in patients with a request for cardiac function assessment. We strongly recommend that clinical requests for cardiac CT should be carefully considered in the paediatric population

    A patient with pulmonary hypertension waiting for donor lungs during the pandemic: 194 days on extracorporeal life support including 143 days on pulmonary artery to left atrium shunt

    No full text
    Patients with pulmonary hypertension and end-stage lung disease are fraught with high mortality while on a waiting list for lung transplant. With sometimes rapid deterioration they may require veno-arterial extracorporeal membrane oxygenation (VA-ECMO) as an immediate life-saving technique, which is a time-limited solution. The technique of pulmonary artery to left atrium (PA-LA) shunt fitted with an oxygenator enables bridging the patient to transplant for a longer time period. This low-resistance paracorporeal pumpless lung assist device allows for de-adaptation of the right ventricle back to lower afterload before the lung transplantation is carried out. The PA-LA shunt with an oxygenator also conveys a risk of multiple complications with reported median of 10-26 days until transplant. We report a case of pulmonary capillary hemangiomatosis in a 35-year-old female who had to wait for donor lungs during the pandemic of SARS-CoV-2 for 143 days on PA-LA shunt with oxygenator following 51 days on VA-ECMO. The extremely long course associated with multiple complications including three cerebral embolisms, episodes of sepsis and ingrowth of the return cannula into the left ventricular wall gives insight into the limits of this bridging technique

    External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model

    No full text
    Background: Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model. Methods: We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy. Results: The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank p = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, p = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 ± 51 mL/min) than in the controls (46 ± 85 mL/min, p = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 ± 1.38 versus 6.94 ± 1.10 mm2, respectively (p = 0.558) and 480 ± 95 vs. 587 ± 52 μm2/μm, respectively (p = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 ± 0.64 vs. 6.27 ± 0.64 mm2, respectively (p = 0.022) and 258 ± 49 vs. 518 ± 36 μm2/μm, respectively (p = 0.0002). Conclusions: In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls

    Data_Sheet_1_Impact of liver fibrosis and nodules formation on hemodynamics in young adults after total cavopulmonary connection. A magnetic resonance study.pdf

    No full text
    BackgroundThe aim of this study was to analyze the relation between the hepatic fibrosis markers, liver morphology and hemodynamics assessed by magnetic resonance imaging (MRI) after total cavopulmonary connection (TCPC).Materials and methodsAdult patients after TCPC performed in childhood between 1993 and 2003 are the subjects of this observational study. The follow-up protocol consisted of clinical and echocardiographic examination, liver elastography, cardiopulmonary exercise test, MRI hemodynamics and liver morphology assessment and direct enhanced liver fibrosis (ELF) test.ResultsThe cohort consisted of 39 patients (46% female) with a median age at study 26 (IQR 23–28) years and interval from TCPC 21 (IQR 20–23) years. There was no correlation between ELF test and any MRI variables, but procollagen III amino-terminal peptide (PIIINP), a single component of ELF test, correlated significantly with ventricular end-diastolic volume (r = 0.33; p = 0.042) and inferior vena cava flow (r = 0.47; p = 0.003). Fifteen (38%) patients with liver nodules had compared to other 24 patients higher end-diastolic volume (ml/m2) 102.8 ± 20.0 vs. 88.2 ± 17.7; p = 0.023, respectively. PIIINP correlated significantly with inferior vena cava flow (r = 0.56; p = 0.030) and with end-diastolic volume (r = 0.53; p = 0.043), but only in patients with liver nodules.ConclusionGradual progression of liver fibrosis, particularly hepatic arterialization caused by liver nodules formation, increases inferior vena cava flow and subsequent ventricular volume overload may further compromise single ventricle functional reserve in adult patients after TCPC.</p

    Vascular Remodeling of Clinically Used Patches and Decellularized Pericardial Matrices Recellularized with Autologous or Allogeneic Cells in a Porcine Carotid Artery Model

    No full text
    Background: Cardiovascular surgery is confronted by a lack of suitable materials for patch repair. Acellular animal tissues serve as an abundant source of promising biomaterials. The aim of our study was to explore the bio-integration of decellularized or recellularized pericardial matrices in vivo. Methods: Porcine (allograft) and ovine (heterograft, xenograft) pericardia were decellularized using 1% sodium dodecyl sulfate ((1) Allo-decel and (2) Xeno-decel). We used two cell types for pressure-stimulated recellularization in a bioreactor: autologous adipose tissue-derived stromal cells (ASCs) isolated from subcutaneous fat of pigs ((3) Allo-ASC and (4) Xeno-ASC) and allogeneic Wharton’s jelly mesenchymal stem cells (WJCs) ((5) Allo-WJC and (6) Xeno-WJC). These six experimental patches were implanted in porcine carotid arteries for one month. For comparison, we also implanted six types of control patches, namely, arterial or venous autografts, expanded polytetrafluoroethylene (ePTFE Propaten® Gore®), polyethylene terephthalate (PET Vascutek®), chemically stabilized bovine pericardium (XenoSure®), and detoxified porcine pericardium (BioIntegral® NoReact®). The grafts were evaluated through the use of flowmetry, angiography, and histological examination. Results: All grafts were well-integrated and patent with no signs of thrombosis, stenosis, or aneurysm. A histological analysis revealed that the arterial autograft resembled a native artery. All other control and experimental patches developed neo-adventitial inflammation (NAI) and neo-intimal hyperplasia (NIH), and the endothelial lining was present. NAI and NIH were most prominent on XenoSure® and Xeno-decel and least prominent on NoReact®. In xenografts, the degree of NIH developed in the following order: Xeno-decel > Xeno-ASC > Xeno-WJC. NAI and patch resorption increased in Allo-ASC and Xeno-ASC and decreased in Allo-WJC and Xeno-WJC. Conclusions: In our setting, pre-implant seeding with ASC or WJC had a modest impact on vascular patch remodeling. However, ASC increased the neo-adventitial inflammatory reaction and patch resorption, suggesting accelerated remodeling. WJC mitigated this response, as well as neo-intimal hyperplasia on xenografts, suggesting immunomodulatory properties
    corecore