4 research outputs found

    Emergently Alteration of Procedural Strategy During Transcatheter Aortic Valve Replacement to Prevent Coronary Occlusion: A Case Report

    Get PDF
    BackgroundCoronary occlusion is an uncommon but fatal complication of transcatheter aortic valve replacement (TAVR) with a poor prognosis.Case PresentationA patient with symptomatic severe bicuspid aortic valve stenosis was admitted to a high-volume center specializing in transfemoral TAVR with self-expanding valves. No anatomical risk factors of coronary occlusion were identified on pre-procedural computed tomography analysis. The patient was scheduled for a transfemoral TAVR with a self-expanding valve. Balloon pre-dilatation prior to prosthesis implantation was routinely used for assessing the supra-annular structure and assessing the risk of coronary occlusion. Immediately after the tubular balloon inflation, fluoroscopy revealed that the right coronary artery was not visible, and the flow in the left coronary artery was reduced. The patient would be at high-risk of coronary occlusion if a long stent self-expanding valve was implanted. Therefore, our heart team decided to suspend the ongoing procedure. A transapical TAVR with a 23 mm J-valve was performed 3 days later. The prosthesis was deployed at a proper position without blocking the coronary ostia and the final fluoroscopy showed normal flow in bilateral coronary arteries with the same filling as preoperatively.DiscussionOur successful case highlights the importance of a comprehensive assessment of coronary risk and a thorough understanding of the TAVR procedure for the heart team. A short-stent prosthesis is feasible for patients at high risk of coronary occlusion. Most importantly TAVR should be called off even if the catheter has been introduced when an extremely high risk of coronary obstruction is identified during the procedure and no solution can be found

    Technical Success after Transcatheter Aortic Valve Replacement for Bicuspid versus Tricuspid Aortic Stenosis

    No full text
    Background: Comparative data of the Valve Academic Research Consortium (VARC-3)-defined technical success between bicuspid versus tricuspid aortic stenosis (AS) remain lacking. Aims: We sought to compare the technical success and other clinical outcomes between patients with bicuspid and tricuspid AS receiving transcatheter aortic valve replacement. Methods: A registration-based analysis was performed for 402 patients (211 and 191 cases of bicuspid and tricuspid AS, respectively). The primary outcome was VARC-3-defined technical success. Additional analysis was performed to assess outcomes for up to one year between the two groups. Results: Bicuspid AS patients tended to be younger (74 years vs. 77 years; p p = 0.003). Bicuspid AS patients showed a lower prevalence of hypertension and peripheral vascular diseases. Technical failure was encountered in 17.7% of these patients, driven primarily by the high incidence of second valve implantation. The technical success rates were comparable between the bicuspid and tricuspid AS groups (82.5% vs. 82.2%, p = 0.944). Chronic kidney disease (CKD) and larger sinotubular junctional diameter (STJ) were identified as predictors of technical failure, whereas CKD, impaired left ventricular ejection fraction (LVEF), along with larger STJ, were predictors of cardiac technical failure. Technical failure was associated with an increased risk of all-cause mortality at 30 days and 1 year, as evidenced by the Cox multivariable analysis. Conclusions: No significant differences were observed in the technical success rates and most clinical outcomes between the bicuspid and tricuspid AS groups. Technical failure conferred an increased risk for both 30-day and 1-year all-cause mortalities

    Impact of repositioning on brain injury following transcatheter aortic valve replacement with a self-expanding valve

    No full text
    Abstract Repositionable self-expanding valves allow for repositioning during deployment to achieve optimal valve placement. However, the risk of brain injury associated with repositioning, as detected by diffusion-weighted magnetic resonance imaging (DW-MRI), is unknown. Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with repositionable self-expanding valves and receiving DW-MRI before and within 7 days post-TAVR procedure were included. The primary outcomes were incidence, number, total volume, and volume per lesion of the cerebral ischemic lesion in DW-MRI after TAVR. Univariate and multivariate logistic regression assessed the association between repositioning and bigger total lesion volume (> 1 cm3 or > 0.5 cm3). Negative binomial regressions were performed to explore the association between repositioning and number of lesions. A propensity score matching was performed to adjust the potential confounders. Moreover, inverse probability of treatment weighted regression model with nonstabilized weights was used as sensitivity analysis. Among 243 included patients, repositioning was performed in 116 (47.7%) patients. The incidence of overt stroke (1.7% vs. 1.6%, p = 0.927) and silent stroke (86.2% vs. 85.8%, p = 0.932) were comparable between two groups. However, the number of new lesions (5.0 [2.0–9.0] vs. 3.0 [2.0–6.0], p = 0.048), and total lesion volume (275.0 [90.0–947.5] mm3 vs. 180.0 [50.0–440.0] mm3, p = 0.022) were significantly higher in the repositioned group. Moreover, the proportion of patients with lesion size greater than 0.5 cm3 was higher in the repositioned group (37.9% vs. 22.0%, p = 0.007). The similar results were observed after propensity score matching. In both multivariate regression model and sensitivity analysis, the repositioning was the independent predictor of number of lesions and bigger total lesion volume after TAVR. The utilization of the repositioning feature may increase the number and volume of silent brain infarcts in DW-MRI in patients who underwent TAVR. (Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population [TORCH]; NCT02803294

    Cerebral Ischemic Lesions after Transcatheter Aortic Valve Implantation in Patients with Non-Calcific Aortic Stenosis

    No full text
    Evidence for transcatheter aortic valve implantation (TAVI) is scarce among patients with non-calcific aortic stenosis, and it is not known whether aortic valve calcification is associated with new cerebral ischemic lesions (CILs) that are detected by diffusion-weighted magnetic resonance imaging. So, our study enrolled 328 patients who underwent transfemoral TAVI using a self-expanding valve between December 2016 and June 2021 from the TORCH registry (NCT02803294). A total of 34 patients were finally confirmed as non-calcific AS and the remaining 294 patients were included in the calcific AS group. Incidence of new CILs (70.6% vs. 85.7%, p = 0.022), number of lesions (2.0 vs. 3.0, p = 0.010), and lesions volume (105.0 mm3 vs. 200.0 mm3, p = 0.047) was significantly lower in the non-calcific AS group. However, the maximum and average lesion volumes were comparable between two groups. Non-calcific AS was associated with lower risk for developing new CILs by univariate logistic regression analysis [Odds ratio (OR): 0.040, 95% confident interval (CI): 0.18–0.90, p = 0.026] and multivariate analysis (OR: 0.031, 95% CI: 0.13–0.76, p = 0.010). In summary, non-calcific AS patients had a lower risk of developing new cerebral ischemic infarction after TAVI compared to calcific AS patients. However, new ischemic lesions were still found in over 70% of patients
    corecore