1,775 research outputs found

    Identification of photons in double beta-decay experiments using segmented germanium detectors - studies with a GERDA Phase II prototype detector

    Get PDF
    The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce this background component. The GERmanium Detector Array, GERDA, will use highly segmented germanium detectors in its second phase. The identification of photonic events is investigated using a prototype detector. The results are compared with Monte Carlo data.Comment: 20 pages, 7 figures, to be submitted to NIM-

    Pulse shape simulation for segmented true-coaxial HPGe detectors

    Get PDF
    A new package to simulate the formation of electrical pulses in segmented true-coaxial high purity germanium detectors is presented. The computation of the electric field and weighting potentials inside the detector as well as of the trajectories of the charge carriers is described. In addition, the treatment of bandwidth limitations and noise are discussed. Comparison of simulated to measured pulses, obtained from an 18-fold segmented detector operated inside a cryogenic test facility, are presented.Comment: 20 pages, 16 figure

    Axes determination for segmented true-coaxial HPGe detectors

    Get PDF
    A fast method to determine the crystallographic axes of segmented true-coaxial high-purity germanium detectors is presented. It is based on the analysis of segment-occupancy patterns obtained by irradiation with radioactive sources. The measured patterns are compared to predictions for different axes orientations. The predictions require a simulation of the trajectories of the charge carriers taking the transverse anisotropy of their drift into account.Comment: 18 pages, 1 table, 31 figures; included background contribution to the occupancy patterns and systematic uncertainties, results slightly change

    Investigation into the limits of perturbation theory at low Q^2 using HERA deep inelastic scattering data

    Get PDF
    A phenomenological study of the final combined HERA data on inclusive deep inelastic scattering (DIS) has been performed. The data are presented and investigated for a kinematic range extending from values of the four-momentum transfer, Q2Q^2, above 104^4 GeV2^2 down to the lowest values observable at HERA of Q2Q^2 = 0.045 GeV2^2 and Bjorken xx, xBjx_{\rm Bj} = 6 \cdot 107^{-7}. The data are well described by fits based on perturbative quantum chromodynamics (QCD) using collinear factorisation and evolution of the parton densities encompassed in the DGLAP formalism from the highest Q2Q^2 down to Q2Q^2 of a few GeV2^2. The Regge formalism can describe the data up to Q2Q^2 \approx 0.65 GeV2^2. The complete data set can be described by a new fit using the ALLM parameterisation. The region between the Regge and the perturbative QCD regimes is of particular interest.Comment: 38 pages, 13 figure

    The GALATEA Test-Facility for High Purity Germanium Detectors

    Full text link
    GALATEA is a test facility designed to investigate bulk and surface effects in high purity germanium detectors. A vacuum tank houses an infrared screened volume with a cooled detector inside. A system of three stages allows an almost complete scan of the detector. The main feature of GALATEA is that there is no material between source and detector. This allows the usage of alpha and beta sources as well as of a laser beam to study surface effects. A 19-fold segmented true-coaxial germanium detector was used for commissioning

    Characterization of the first true coaxial 18-fold segmented n-type prototype detector for the GERDA project

    Get PDF
    The first true coaxial 18-fold segmented n-type HPGe prototype detector produced by Canberra-France for the GERDA neutrinoless double beta-decay project was tested both at Canberra-France and at the Max-Planck-Institut fuer Physik in Munich. The main characteristics of the detector are given and measurements concerning detector properties are described. A novel method to establish contacts between the crystal and a Kapton cable is presented.Comment: 21 pages, 16 Figures, to be submitted to NIM

    Measurement of the temperature dependence of pulse lengths in an n-type germanium detector

    Full text link
    The temperature dependence of the pulse length was measured for an 18-fold segmented n-type germanium detector in the temperature range of 77-120 K. The interactions of 122 keV photons originating from a Europium-152 source were selected and pulses as observed on the core and segment electrodes were studied. In both cases, the temperature dependence can be well described by a Boltzmann-like ansatz.Comment: 17 pages, 2 tables, 13 figures, published in EPJ A

    Speckle Interferometry of Metal-Poor Stars in the Solar Neighborhood. I

    Full text link
    We report the results of speckle-interferometric observations of 109 high proper-motion metal-poor stars made with the 6-m telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences. We resolve eight objects -- G102-20, G191-55, BD+19^\circ~1185A, G89-14, G87-45, G87-47, G111-38, and G114-25 -- into individual components and we are the first to astrometrically resolve seven of these stars. New resolved systems included two triple (G111-38, G87-47) and one quadruple (G89-14) star. The ratio of single-to-binary-to-triple-to-quadruple systems among the stars of our sample is equal to 71:28:6:1.Comment: 8 pages, 4 figures, accepted to Astrophysical Bulleti
    corecore