2,199 research outputs found

    On b- and tau-multiplicities per event in SUSY (mSUGRA) and instrumental implications

    Full text link
    We investigate the probability to find a b or tau in SUSY production with the mSUGRA model. We find that in the entire parameter space the probability per event to find a b-jet of E_T^b > 50 GeV within CMS acceptance (eta < 2.4) is significant for all tan(beta), varying from a 10 % level to 90 % depending on the m_0, m_1/2 region. The probabilities per event to find a tau with the same kinematical cuts is also significant and it increases sharply with tan(beta). These findings point to the central role a microvertex device would play in case that SUSY (mSUGRA) is indeed realized in nature and found at the LHC. First investigations done in the context of the more general MSSM scenario confirm the findings based on mSUGRA.Comment: 19 pages, 13 figures, 3 table

    Study of leptoquark pair production at the LHC with the CMS detector

    Get PDF
    We study the discovery potential of the CMS detector for the scalar leptoquark pair production at the LHC. Present and future exclusion limits are considered. We find that the maximal leptoquark mass reach is about 1.47 TeV for the branching ratio of Br(LQ_l -> l q)=100 %, while for Br(LQ_l -> l q)=50 % the upper limit is 1.2 TeV for an integrated luminosity of 100 fb-1. We obtain comparable results for electron and muon-type leptoquarks. The pileup effect at high luminosity is discussed.Comment: 10 pages, 7 figures, 4 tables, UNIX LaTe

    Calorimetry Task Force Report

    Get PDF
    In this note we summarize the studies and recommendations of the calorimeter simulation task force (CaloTF). The CaloTF was established in February 2008 in order to understand and reconcile the discrepancies observed between the CMS calorimetry simulation and the test beam data recorded during 2004 and 2006. As the result of studies by the CaloTF a new version of Geant4 was developed and introduced in the CMS detector simulation leading to significanly better agreement with test beam data. Fast and flexible parameterizations describing showering in the calorimeter are introduced both in the Full Simulation (with a Gflash-like approach) and in the Fast Simulation. The CaloTF has developed a strategy to rapidly tune the CMS calorimeter simulation using the first LHC collision data when it becomes available. The improvements delivered by the CaloTF have been implemented in the software release CMSSW 2.1.0

    Simultaneous Search for Two Higgs Bosons of Minimal Supersymmetry at the LHC

    Get PDF
    The prospects of detecting the CP-odd Higgs pseudoscalar (AA) in the minimal supersymmetric model via its decay into a ZZ boson and the lighter CP-even Higgs scalar (hh) at the CERN Large Hadron Collider are investigated. The final state of Zl+lZ \to l^+l^- and hbbˉh \to b\bar{b}, may provide a promising way to simultaneously detect the AA and the hh. The compact muon solenoid detector performance is adopted for a realistic study of observability. In this discovery channel, the masses of the hh and the AA can be reconstructed. The impact of supersymmetric decay modes is considered.Comment: 17 pages, REVTEX, 6 figure

    Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    Get PDF
    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile

    Synchronization and Timing in CMS HCAL

    Get PDF
    The synchronization and timing of the hadron calorimeter (HCAL) for the Compact Muon Solenoid has been extensively studied with test beams at CERN during the period 2003-4, including runs with 40 MHz structured beam. The relative phases of the signals from different calorimeter segments are timed to 1 ns accuracy using a laser and equalized using programmable delay settings in the front-end electronics. The beam was used to verify the timing and to map out the entire range of pulse shapes over the 25 ns interval between beam crossings. These data were used to make detailed measurements of energy-dependent time slewing effects and to tune the electronics for optimal performance

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Design, Performance, and Calibration of the CMS Hadron-Outer Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with an outer calorimeter to ensure high energy shower containment in the calorimeter. Fabrication, testing and calibration of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter will also be used for the muon trigger in coincidence with other muon chambers in CMS
    corecore