81 research outputs found

    Predictive equations over-estimate the resting energy expenditure in amyotrophic lateral sclerosis patients who are dependent on invasive ventilation support

    Get PDF
    BackgroundAmyotrophic lateral sclerosis (ALS) is a form of degenerative motor neuron disease. At the end stage of the disease artificial feeding is often required. Nevertheless, very little is known about the energy demand of those ALS patients who are chronically dependent on tracheostomy intermittent positive pressure ventilation. The objective of our study was to clarify the resting energy expenditure (REE) in mechanically ventilated ALS patients.MethodsWe measured the REE of five ALS patients (four men, one female) twice during a 12 month-period using indirect calorimetry with two sampling flow settings (40 L/min and 80 L/min). The measured REEs (mREE) were compared with values calculated using five different predictive equations.ResultsThe mean (Âą SD) of all mREEs was 1130 Âą 170 kcal/d. The measurements with different flow settings and at different time instances provided similar results. The mean of mREEs was 33.6% lower, as compared to the mean calculated with five different predictive equations REE (p ConclusionsThe mREE values were significantly lower for every patient than all the predicted ones. Determination of daily nutrition with predictive equations may therefore lead in mis-estimation of energy requirements. Because ALS patients may live years with artificial ventilation their nutritional support should be based on individual measurements. However, further study is needed due to the small number of subjects.</p

    Using respiratory rate and thoracic movement to assess respiratory insufficiency in amyotrophic lateral sclerosis: a preliminary study

    Get PDF
    ackgroundHypoventilation due to respiratory insufficiency is the most common cause of death in amyotrophic lateral sclerosis (ALS) and non-invasive ventilation (NIV) can be used as a palliative treatment. The current guidelines recommend performing spirometry, and recording nocturnal oxyhemoglobin saturation and arterial blood gas analysis to assess the severity of the hypoventilation. We examined whether the respiratory rate and thoracic movement were reliable preliminary clinical signs in the development of respiratory insufficiency in patients with ALS.MethodsWe measured the respiratory rate and thoracic movement, performed respiratory function tests and blood gas analysis, and recorded subjective hypoventilation symptoms in 42 ALS patients over a 7-year period. We recommended NIV if the patient presented with hypoventilation matching the current guidelines. We divided patients retrospectively into two groups: those to whom NIV was recommended within 6 months of the diagnosis (Group 1) and those to whom NIV was recommended 6 months after the diagnosis (Group 2). We used the Mann Whitney U test for comparisons between the two groups.ResultsThe mean partial pressure of arterial carbon dioxide in the morning in Group 1 was 6.3 (95% confidence interval 5.6–6.9) kPa and in Group 2 5.3 (5.0–5.6) kPa (p = 0.007). The mean respiratory rate at the time of diagnosis in Group 1 was 21 (18–24) breaths per minute and 16 (14–18) breaths per minute in Group 2 (p = 0.005). The mean thoracic movement was 2.9 (2.2–3.6) cm in Group 1 and 4.0 (3.4–4.8) cm in Group 2 (p = 0.01). We observed no other differences between the groups.ConclusionsPatients who received NIV within six months of the diagnosis of ALS had higher respiratory rates and smaller thoracic movement compared with patients who received NIV later. Further studies with larger numbers of patients are needed to establish if these measurements can be used as a marker of hypoventilation in ALS.</p

    Highly variable pharmacokinetics of dexmedetomidine during intensive care: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Dexmedetomidine is a selective and potent alpha2-adrenoceptor agonist licensed for use in the sedation of patients initially ventilated in intensive care units at a maximum dose rate of 0.7 Îźg/kg/h administered for up to 24 hours. Higher dose rates and longer infusion periods are sometimes required to achieve sufficient sedation. There are some previous reports on the use of long-term moderate to high-dose infusions of dexmedetomidine in patients in intensive care units, but none of these accounts have cited dexmedetomidine plasma concentrations.</p> <p>Case presentation</p> <p>We describe the case of a 42-year-old Caucasian woman with severe hemorrhagic pancreatitis following laparoscopic cholecystectomy who received dexmedetomidine for 24 consecutive days at a maximum dose rate of 1.9 Îźg/kg/h. Samples for the measurement of dexmedetomidine concentrations in her plasma were drawn at intervals of eight hours. On average, the observed plasma concentrations were well in accordance with previous knowledge on the pharmacokinetics of dexmedetomidine. There was, however, marked variability in the concentration of dexmedetomidine in her plasma despite a stable infusion rate.</p> <p>Conclusion</p> <p>The pharmacokinetics of dexmedetomidine appears to be highly variable during intensive care.</p

    Validation of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation support

    Get PDF
    The aim of this validation study was to assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo non-invasive ventilation (NIV). Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in twelve healthy volunteers. Respiratory quotient (RQ) and resting energy expenditure (REE) were then calculated from the measured VO2 and VCO2 values. During the measurement period the subjects were breathing spontaneously and ventilated using NIV. Two different sampling air flow values 40 and 80 l/min were used. The gas leakage from the measurement setup was assessed with a separate capnograph. The mean weight of the subjects was 93 kg. Their mean body mass index was 29 (range 22-40) kg/m(2). There was no statistically significant difference in the measured values for VO2, VCO2, RQ and REE during NIV-supported breathing and spontaneous breathing. The change of sampling air flow had no statistically significant effect on any of the above parameters. We found that REE can be accurately measured with an indirect calorimeter also during NIV-supported breathing and the change of sampling air flow does not distort the gas exchange measurement. A higher sampling air flow in indirect calorimetry decreases the possibility for air leakages in the measurement system and increases the reliability of REE measurement

    Subcutaneously administered dexmedetomidine is efficiently absorbed and is associated with attenuated cardiovascular effects in healthy volunteers

    Get PDF
    Purpose: Palliative care patients often need sedation to alleviate intractable anxiety, stress, and pain. Dexmedetomidine is used for sedation of intensive care patients, but there is no prior information on its subcutaneous (SC) administration, a route that would be favored in palliative care. We compared the pharmacokinetics and cardiovascular, sympatholytic, and sedative effects of SC and intravenously (IV) administered dexmedetomidine in healthy volunteers.Methods: An open two-period, cross-over design with balanced randomization was used. Ten male subjects were randomized to receive 1 μg/kg dexmedetomidine both IV and SC. Concentrations of dexmedetomidine and catecholamines in plasma were measured. Pharmacokinetic variables were calculated with non-compartmental methods. In addition, cardiovascular and sedative drug effects were monitored.Results: Eight subjects completed both treatment periods. Peak concentrations of dexmedetomidine were observed 15 min after SC administration (median; range 15–240). The mean bioavailability of SC dexmedetomidine was 81% (AUC0-∞ ratio × 100%, range 49–97%). The mean (SD) peak concentration of dexmedetomidine in plasma was 0.3 (0.1) ng/ml, and plasma concentrations associated with sedative effects (i.e., > 0.2 ng/ml) were maintained for 4 h after SC dosing. Plasma noradrenaline concentrations were significantly lower (P Conclusions: Dexmedetomidine is relatively rapidly and efficiently absorbed after SC administration. Subcutaneous dexmedetomidine may be a feasible alternative in palliative sedation, and causes attenuated cardiovascular effects compared to IV administration.</p

    A multinational, drug utilization study to investigate the use of dexmedetomidine (Dexdor (R)) in clinical practice in the EU

    Get PDF
    AIMSDexmedetomidine (dexdor (R)) is approved in the European Union (EU) for sedation of adults in the intensive care unit (ICU). The present observational, retrospective study was requested by the European Medicines Agency to investigate dexmedetomidine use in clinical practice, with a particular focus on off-label use, including the paediatric population.METHODSStudy countries and sites were chosen from those with highest dexmedetomidine use, based on sales. Site selection (blind) was conducted by a multispecialist, independent group. Anonymized data on demographics, treatment indication, dexmedetomidine dosing, concomitant medications and treatment effectiveness were collected retrospectively from records of all dexmedetomidine-treated patients at the site during the enrolment period. Informed consent was waived, to avoid influencing the prescribing of dexmedetomidine. Recruitment was completed within 18 months of first site initiation.RESULTSData from 2000 patients were collected from 16 hospitals in four EU countries (Finland 750, Poland 505, Germany 470, Austria 275). The median age was 62 years, with more males (70.2%) than females. Dexmedetomidine was primarily used in the adult ICU (86.0%) for ICU sedation (78.6%) and mostly dosed according the product label. The intended sedative effect was obtained in 84.9% of administrations. Paediatric use (5.9% of patients, mostly in Austria and Finland) occurred mainly in the adult or paediatric ICU (75.6%) for sedation (67.2%).CONCLUSIONSOverall, most patients were treated with dexmedetomidine according to the product labelling. Use in children was limited but significant and similar in scope to that in adults. Administrations not fully according to the product labelling usually occurred in an ICU environment and reflected extensively investigated clinical uses of dexmedetomidine

    Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one case of awareness in the high-risk population was 138. Since the number needed to treat and the associated cost of treatment would be much higher in the general population, the efficacy of the Bispectral Index monitor in preventing awareness in all anesthetized patients needs to be clearly established. This is especially true given the findings of the B-Unaware trial, which demonstrated no significant difference between protocols based on the Bispectral Index monitor or minimum alveolar concentration for the reduction of awareness in high risk patients.</p> <p>Methods/Design</p> <p>To evaluate efficacy in the general population, we are conducting a prospective, randomized, controlled trial comparing the Bispectral Index monitor to a non-electroencephalographic gauge of anesthetic depth. The total recruitment for the study is targeted for 30,000 patients at both low and high risk for awareness. We have developed a novel algorithm that is capable of real-time analysis of our electronic perioperative information system. In one arm of the study, anesthesia providers will receive an electronic page if the Bispectral Index value is >60. In the other arm of the study, anesthesia providers will receive a page if the age-adjusted minimum alveolar concentration is <0.5. Our minimum alveolar concentration algorithm is sensitive to both inhalational anesthetics and intravenous sedative-hypnotic agents.</p> <p>Discussion</p> <p>Awareness during general anesthesia is a persistent problem and the role of the Bispectral Index monitor in its prevention is still unclear. The Michigan Awareness Control Study is the largest prospective trial of awareness prevention ever conducted.</p> <p>Trial Registration</p> <p>Clinical Trial NCT00689091</p

    Clinical Pharmacokinetics and Pharmacodynamics of Dexmedetomidine

    Get PDF
    • …
    corecore