28 research outputs found

    Acute hypoxia increases the cerebral metabolic rate:a magnetic resonance imaging study

    Get PDF
    The aim of the present study was to examine changes in cerebral metabolism by magnetic resonance imaging of healthy subjects during inhalation of 10% O(2) hypoxic air. Hypoxic exposure elevates cerebral perfusion, but its effect on energy metabolism has been less investigated. Magnetic resonance imaging techniques were used to measure global cerebral blood flow and the venous oxygen saturation in the sagittal sinus. Global cerebral metabolic rate of oxygen was quantified from cerebral blood flow and arteriovenous oxygen saturation difference. Concentrations of lactate, glutamate, N-acetylaspartate, creatine and phosphocreatine were measured in the visual cortex by magnetic resonance spectroscopy. Twenty-three young healthy males were scanned for 60 min during normoxia, followed by 40 min of breathing hypoxic air. Inhalation of hypoxic air resulted in an increase in cerebral blood flow of 15.5% (p = 0.058), and an increase in cerebral metabolic rate of oxygen of 8.5% (p = 0.035). Cerebral lactate concentration increased by 180.3% ([Formula: see text]), glutamate increased by 4.7% ([Formula: see text]) and creatine and phosphocreatine decreased by 15.2% (p [Formula: see text]). The N-acetylaspartate concentration was unchanged (p = 0.36). In conclusion, acute hypoxia in healthy subjects increased perfusion and metabolic rate, which could represent an increase in neuronal activity. We conclude that marked changes in brain homeostasis occur in the healthy human brain during exposure to acute hypoxia

    Comparison of Global Cerebral Blood Flow Measured by Phase-Contrast Mapping MRI with O-15-H2O Positron Emission Tomography

    Get PDF
    PURPOSE: To compare mean global cerebral blood flow (CBF) measured by phase‐contrast mapping magnetic resonance imaging (PCM MRI) and by (15)O‐H(2)O positron emission tomography (PET) in healthy subjects. PCM MRI is increasingly being used to measure mean global CBF, but has not been validated in vivo against an accepted reference technique. MATERIALS AND METHODS: Same‐day measurements of CBF by (15)O‐H(2)O PET and subsequently by PCM MRI were performed on 22 healthy young male volunteers. Global CBF by PET was determined by applying a one‐tissue compartment model with measurement of the arterial input function. Flow was measured in the internal carotid and vertebral arteries by a noncardiac triggered PCM MRI sequence at 3T. The measured flow was normalized to total brain weight determined from a volume‐segmented 3D T (1)‐weighted anatomical MR‐scan. RESULTS: Mean CBF was 34.9 ± 3.4 mL/100 g/min measured by (15)O‐H(2)O PET and 57.0 ± 6.8 mL/100 g/min measured by PCM MRI. The measurements were highly correlated (P = 0.0008, R(2) = 0.44), although values obtained by PCM MRI were higher compared to (15)O‐H(2)O PET (absolute and relative differences were 22.0 ± 5.2 mL/100 g/min and 63.4 ± 14.8%, respectively). CONCLUSION: This study confirms the use of PCM MRI for quantification of global CBF, but also that PCM MRI systematically yields higher values relative to (15)O‐H(2)O PET, probably related to methodological bias. Level of Evidence: 3 J. Magn. Reson. Imaging 2017;45:692–699

    Transient impairment of the axolemma following regional anaesthesia by lidocaine in humans

    No full text
    The local anaesthetic lidocaine is known to block voltage-gated Na(+) channels (VGSCs), although at high concentration it was also reported to block other ion channel currents as well as to alter lipid membranes. The aim of this study was to investigate whether the clinical regional anaesthetic action of lidocaine could be accounted for solely by the block of VGSCs or whether other mechanisms are also relevant. We tested the recovery of motor axon conduction and multiple measures of excitability by ‘threshold-tracking’ after ultrasound-guided distal median nerve regional anaesthesia in 13 healthy volunteers. Lidocaine caused rapid complete motor axon conduction block localized at the wrist. Within 3 h, the force of the abductor pollicis brevis muscle and median motor nerve conduction studies returned to normal. In contrast, the excitability of the motor axons at the wrist remained markedly impaired as indicated by a 7-fold shift of the stimulus–response curves to higher currents with partial recovery by 6 h and full recovery by 24 h. The strength–duration properties were abnormal with markedly increased rheobase and reduced strength–duration time constant. The changes in threshold during electrotonus, especially during depolarization, were markedly reduced. The recovery cycle showed increased refractoriness and reduced superexcitability. The excitability changes were only partly similar to those previously observed after poisoning with the VGSC blocker tetrodotoxin. Assuming an unaltered ion-channel gating, modelling indicated that, apart from up to a 4-fold reduction in the number of functioning VGSCs, lidocaine also caused a decrease of passive membrane resistance and an increase of capacitance. Our data suggest that the lidocaine effects, even at clinical ‘sub-blocking’ concentrations, could reflect, at least in part, a reversible structural impairment of the axolemma
    corecore