20 research outputs found

    Five-year follow-up of angiographic disease progression after medicine, angioplasty, or surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Progression of atherosclerosis in coronary artery disease is observed through consecutive angiograms. Prognosis of this progression in patients randomized to different treatments has not been established. This study compared progression of coronary artery disease in native coronary arteries in patients undergoing surgery, angioplasty, or medical treatment.</p> <p>Methods</p> <p>Patients (611) with stable multivessel coronary artery disease and preserved ventricular function were randomly assigned to CABG, PCI, or medical treatment alone (MT). After 5-year follow-up, 392 patients (64%) underwent new angiography. Progression was considered a new stenosis of ≥ 50% in an arterial segment previously considered normal or an increased grade of previous stenosis > 20% in nontreated vessels.</p> <p>Results</p> <p>Of the 392 patients, 136 underwent CABG, 146 PCI, and 110 MT. Baseline characteristics were similar among treatment groups, except for more smokers and statin users in the MT group, more hypertensives and lower LDL-cholesterol levels in the CABG group, and more angina in the PCI group at study entry. Analysis showed greater progression in at least one native vessel in PCI patients (84%) compared with CABG (57%) and MT (74%) patients (p < 0.001). LAD coronary territory had higher progression compared with LCX and RCA (P < 0.001). PCI treatment, hypertension, male sex, and previous MI were independent risk factors for progression. No statistical difference existed between coronary events and the development of progression.</p> <p>Conclusion</p> <p>The angioplasty treatment conferred greater progression in native coronary arteries, especially in the left anterior descending territories and treated vessels. The progression was independently associated with hypertension, male sex, and previous myocardial infarction.</p

    Echocardiographic parameters of the freestyle stentless bioprosthesis in aortic position: the European experience.

    No full text
    The objective of this study was to determine normal Doppler and 2-dimensional characteristics of the Freestyle stentless aortic bioprosthesis. The Freestyle aortic bioprosthesis is a new type of aortic xenograft, and experience is limited. We therefore determined the normal range of echocardiographic and Doppler examinations of this valve. Three hundred thirty-nine consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1, 2, and 3 years. With a valve size from 19 to 27 mm, mean gradients decreased from 7.9 +/- 5.1 mm Hg at discharge to 5.5 +/- 3. 8 mm Hg after 3 to 6 months (P &lt;.001). Thereafter, gradients remained stable. Effective orifice area 1 year after implantation was 1.59 +/- 0.58 cm(2) for the 21-mm valves, 1.92 +/- 0.74 cm(2) for the 23-mm valves, 2.03 +/- 0.64 cm(2) for the 25-mm valves, and 2.52 +/- 0.72 cm(2) for the 27-mm valves (P &lt;.001). The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro, increased from 67% +/- 20% at discharge to 82% +/- 29% after 1, 2, and 3 years. Performance index was especially very high in the smaller-sized valves. After implantation with the subcoronary technique or root-inclusion technique, small cavities could be seen between the native aortic root and the Freestyle valve. Doppler values were evaluated for the Freestyle stentless porcine bioprostheses in the aortic root. Gradients appear to be close to those measured in native valves over a time period of 3 years
    corecore