Establishing a gold standard for manual cough counting: video versus digital audio recordings
BACKGROUND: Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. METHODS: We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. RESULTS: The median cough frequency was 17.8 (IQR 5.9ā28.7) cough sounds per hour in the video recordings and 17.7 (6.0ā29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD Ā± 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2ā4 hours of analysis per recording. CONCLUSION: Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment
A phase 1 study evaluating the pharmacokinetics, safety and tolerability of repeat dosing with a human IL-13 antibody (CAT-354) in subjects with asthma
<p>Abstract</p> <p>Background</p> <p>IL-13 has been implicated in the development of airway inflammation and hyperresponsiveness. This study investigated the multiple-dose pharmacokinetics and safety profile of human anti-IL-13 antibody (CAT-354) in adults with asthma.</p> <p>Methods</p> <p>This was a multiple-dose, randomised, double-blind, placebo-controlled phase 1 study in asthmatics (forced expiratory volume in 1 second [FEV<sub>1</sub>] ā„ 80% predicted). Subjects were randomised to receive three intravenous infusions of CAT-354 (1 mg/kg, 5 mg/kg or 10 mg/kg) or placebo at 28-day intervals. Blood samples were taken for pharmacokinetic measurements. Safety was assessed by adverse events, vital signs, ECGs, laboratory and pulmonary function parameters.</p> <p>Results</p> <p>Twenty-three subjects (aged 21-60 years, FEV<sub>1 </sub>88-95% predicted) received ā„ 1 dose of study medication. The half-life of CAT-354 was 12-17 days and was dose-independent. The maximum serum concentration and area under the curve were dose-dependent. Clearance (2.2-2.6 mL/day/kg) and volume of distribution (44-57 mL/kg) were both low and dose-independent. The observed maximum serum concentration after each dose increased slightly from dose 1 through dose 3 at all dose levels, consistent with an accumulation ratio of 1.4 to 1.7 for area under the curve. Most adverse events were deemed mild to moderate and unrelated to study medication. One SAE was reported and deemed unrelated to study drug. There were no effects of clinical concern for vital signs, ECG, laboratory or pulmonary parameters.</p> <p>Conclusions</p> <p>CAT-354 exhibited linear pharmacokinetics and an acceptable safety profile. These findings suggest that at the doses tested, CAT-354 can be safely administered in multiple doses to patients with asthma.</p> <p>Trial registration</p> <p>NCT00974675.</p
Non-invasive biomarkers and pulmonary function in smokers
Limited information exists regarding measurement, reproducibility and interrelationships of non-invasive biomarkers in smokers. We compared exhaled breath condensate (EBC) leukotriene B4 (LTB4) and 8-isoprostane, exhaled nitric oxide, induced sputum, spirometry, plethysmography, impulse oscillometry and methacholine reactivity in 18 smokers and 10 non-smokers. We assessed the relationships between these measurements and within-subject reproducibility of EBC biomarkers in smokers. Compared to non-smokers, smokers had significantly lower MMEF % predicted (mean 64.1 vs 77.7, p = 0.003), FEV1/FVC (mean 76.2 vs 79.8 p = 0.05), specific conductance (geometric mean 1.2 vs 1.6, p = 0.02), higher resonant frequency (mean 15.5 vs 9.9, p = 0.01) and higher EBC 8-isoprostane (geometric mean 49.9 vs 8.9 pg/ml p = 0.001). Median EBC pH values were similar, but a subgroup of smokers had airway acidification (pH < 7.2) not observed in non-smokers. Smokers had predominant sputum neutrophilia (mean 68.5%). Repeated EBC measurements showed no significant differences between group means, but Bland Altman analysis showed large individual variability. EBC 8-isoprostane correlated with EBC LTB4 (r = 0.78, p = 0.0001). Sputum supernatant IL-8 correlated with total neutrophil count per gram of sputum (r = 0.52, p = 0.04) and with EBC pH (r = ā0.59, p = 0.02). In conclusion, smokers had evidence of small airway dysfunction, increased airway resistance, reduced lung compliance, airway neutrophilia and oxidative stress
Long-term effects of allergen sensitization and exposure in adult asthma: a prospective study.
BACKGROUND: : We investigated the effects of sensitization and exposure to common domestic allergens on longitudinal changes in lung function and bronchial hyperresponsiveness. METHODS: : Subjects attended 2 visits that were 4 years apart. Skin prick testing was performed and household dust samples were collected for quantification of mite, dog, and cat allergens at baseline. Measurements of lung function, exhaled nitric oxide, and bronchial hyperresponsiveness were completed at both visits. RESULTS: : Dust samples were collected in 165 of the 200 subjects completing both visits. Mean length of follow-up was 47 months. Bronchial hyperresponsiveness, measured at both visits in 86 subjects, deteriorated in those exposed to high mite allergen levels compared with those not exposed [mean (95% CI) doubling dose change PD20 = -0.44 (-1.07 to 0.19) vs 0.82 (0.27 to 1.36)], but improved in those exposed to high dog allergen levels compared with those not exposed [1.10 (0.33 to 1.86) vs 0.10 (-0.39 to 0.58)]. The associations were significant in the multivariate models. Cat allergen exposure was not associated with any changes in lung function, exhaled nitric oxide, or bronchial hyperresponsiveness. CONCLUSIONS: : In a 4-year prospective cohort of persons with asthma, exposure to high levels of dust mite allergens at baseline was associated with a subsequent increase in bronchial hyperresponsiveness
Gene-Environment Interaction in the Onset of Eczema in Infancy: Filaggrin Loss-of-Function Mutations Enhanced by Neonatal Cat Exposure
Background
Loss-of-function variants in the gene encoding filaggrin (FLG) are major determinants of eczema. We hypothesized that weakening of the physical barrier in FLG-deficient individuals may potentiate the effect of environmental exposures. Therefore, we investigated whether there is an interaction between FLG loss-of-function mutations with environmental exposures (pets and dust mites) in relation to the development of eczema.
Methods and Findings
We used data obtained in early life in a high-risk birth cohort in Denmark and replicated the findings in an unselected birth cohort in the United Kingdom. Primary outcome was age of onset of eczema; environmental exposures included pet ownership and mite and pet allergen levels. In Copenhagen(n = 379), FLG mutation increased the risk of eczema during the first year of life (hazard ratio [HR] 2.26, 95% confidence interval [CI] 1.27ā4.00, p = 0.005), with a further increase in risk related to cat exposure at birth amongst children with FLG mutation (HR 11.11, 95% CI 3.79ā32.60, p < 0.0001); dog exposure was moderately protective (HR 0.49, 95% CI 0.24ā1.01, p = 0.05), but not related to FLG genotype. In Manchester (n = 503) an independent and significant association of the development of eczema by age 12 mo with FLG genotype was confirmed (HR 1.95, 95% CI 1.13ā3.36, p = 0.02). In addition, the risk increased because of the interaction of cat ownership at birth and FLG genotype (HR 3.82, 95% CI 1.35ā10.81, p = 0.01), with no significant effect of the interaction with dog ownership (HR 0.59, 95% CI 0.16ā2.20, p = 0.43). Mite-allergen had no effects in either cohort. The observed effects were independent of sensitisation.
Conclusions
We have demonstrated a significant interaction between FLG loss-of-function main mutations (501x and 2282del4) and cat ownership at birth on the development of early-life eczema in two independent birth cohorts. Our data suggest that cat but not dog ownership substantially increases the risk of eczema within the first year of life in children with FLG loss-of-function variants, but not amongst those without. FLG-deficient individuals may need to avoid cats but not dogs in early life
Objective cough frequency, airway inflammation, and disease control in asthma
Background
Cough is recognized as an important troublesome symptom in the diagnosis and monitoring of asthma. Asthma control is thought to be determined by the degree of airway inflammation and hyperresponsiveness but how these factors relate to cough frequency is unclear. The goal of this study was to investigate the relationships between objective cough frequency, disease control, airflow obstruction, and airway inflammation in asthma.
Methods
Participants with asthma underwent 24-h ambulatory cough monitoring and assessment of exhaled nitric oxide, spirometry, methacholine challenge, and sputum induction (cell counts and inflammatory mediator levels). Asthma control was assessed by using the Global Initiative for Asthma (GINA) classification and the Asthma Control Questionnaire (ACQ). The number of cough sounds was manually counted and expressed as coughs per hour (c/h).
Results
Eighty-nine subjects with asthma (mean Ā± SD age, 57 Ā± 12 years; 57%Ā female) were recruited. According to GINA criteria, 18 (20.2%) patients were classified as controlled, 39 (43.8%) partly controlled, and 32 (36%) uncontrolled; the median ACQ score was 1 (range, 0.0-4.4). The 6-item ACQ correlated with 24-h cough frequency (rĀ = 0.40; PĀ < .001), and patients with uncontrolled asthma (per GINA criteria) had higher median 24-h cough frequency (4.2 c/h; range, 0.3-27.6) compared with partially controlled asthma (1.8 c/h; range, 0.2-25.3; PĀ = .01) and controlled asthma (1.7 c/h; range, 0.3-6.7; PĀ = .002). Measures of airway inflammation were not significantly different between GINA categories and were not correlated with ACQ. In multivariate analyses, increasing cough frequency and worsening FEV1 independently predicted measures of asthma control.
Conclusions
Ambulatory cough frequency monitoring provides an objective assessment of asthma symptoms that correlates with standard measures of asthma control but not airflow obstruction or airway inflammation. Moreover, cough frequency and airflow obstruction represent independent dimensions of asthma control
Thoughtful prescription of inhaled medication has the potential to reduce inhaler-related greenhouse gas emissions by 85
INTRODUCTION: Both physicians and patients are increasingly aware of the environmental impacts of medication. The shift of treatment paradigm towards MART-treatment (Maintenance and Reliever Therapy) in asthma affects the treatment-related emissions. The carbon footprint of inhaled medication is also tied to the type of the device used. Today the most commonly used propellant-containing pressurised metered-dose inhalers (pMDIs) have a carbon footprint typically 20-40-fold higher than propellant-free dry powder inhalers (DPIs) and soft mist inhalers. METHODS: We analysed the carbon footprint of inhaled medications in Europe using published life cycle analyses of marketed inhalers and comprehensive 2020 European sales data. In addition, we give an estimate on treatment-related emissions of different treatment regimens on Global Initiative for Asthma (GINA) step 2. RESULTS: There is potential to reduce the carbon footprint of inhaled medications by 85% if DPIs are preferred over pMDIs. Emissions from pMDIs in the EU were estimated to be 4.0 megatons of carbon dioxide equivalent (MT CO2e) and this could be reduced to 0.6 MT CO2e if DPIs were used instead. In the treatment of moderate asthma with DPI, an as-needed combination of inhaled corticosteroid and long-acting beta-agonist in a single inhaler had a substantially lower annual carbon footprint (0.8ākg CO2e) than the more traditional maintenance therapy with an inhaled corticosteroid alone with as-needed short-acting beta-agonist (2.9ākg CO2e). DISCUSSION: There has been an urgent call for healthcare to reduce its carbon footprint for appropriate patients with asthma and chronic obstructive pulmonary disease (COPD), changing to non-propellant inhalers can reduce the carbon footprint of their treatment by almost 20-fold.Peer reviewe
Efficacy and safety of fluticasone furoate 100Ā Ī¼g and 200Ā Ī¼g once daily in the treatment of moderate-severe asthma in adults and adolescents: a 24-week randomised study
Background: Inhaled corticosteroids are a mainstay of therapy for persistent asthma, but suboptimal adherence with twice-daily use is widespread. Fluticasone furoate (FF) is a new inhaled corticosteroid (ICS) suitable for once-daily dosing in asthma. This study was performed to descriptively assess the efficacy and safety of two doses of FF, with no planned formal statistical hypothesis testing.
Methods: This was a 24-week double-blind, multicentre, parallel-group study (NCT01431950). Patients aged ā„ 12 years with moderate-severe persistent asthma and uncontrolled on mid-high dose ICS were stratified by baseline FEV1 and randomised (1:1) to treatment with FF 100 Ī¼g or 200 Ī¼g once daily in the evening. The primary endpoint was change from baseline trough FEV1 after 24 weeks; secondary and other endpoints included peak expiratory flow (PEF) and rescue-free and symptom-free 24-hour periods over Weeks 1ā24, and Asthma Control Testā¢ (ACT) score at Week 24. A pre-specified subgroup analysis of patients by randomisation strata was performed for the primary and selected secondary and other endpoints. Safety assessments included adverse events, laboratory and vital sign measurements, and change from baseline in 24-hour urinary cortisol at Week 24.
Results: With FF 100 Ī¼g and 200 Ī¼g, least squares mean trough FEV1 improved from baseline by 208 mL and 284 mL, respectively, at Week 24; treatment difference: 77 mL (95% CI: ā39, 192). Similar improvements from baseline in rescue- and symptom-free periods, and morning and evening PEF were observed in both groups. Patients were 42% more likely to be well-controlled (ACT score ā„ 20) with FF 200 Ī¼g than with FF 100 Ī¼g. Slightly more patients receiving FF 200 Ī¼g vs. FF 100 Ī¼g reported adverse events (63% vs. 59%) and events deemed treatment related (5% vs. <1%). Seven serious adverse events (FF 200 Ī¼g 4; FF 100 Ī¼g 3) were reported, none of which were deemed treatment related. No clinically relevant effects of either dose on 24-hour urinary cortisol were observed.
Conclusion: Improvements from baseline in trough FEV1 were observed after 24 weeks of treatment with both doses of FF, with a numerically greater improvement in FEV1 observed in patients receiving FF 200 Ī¼g. Secondary endpoint findings were similar between groups. No safety concerns were identified during the study
Efficacy and safety of once-daily fluticasone furoate 50 mcg in adults with persistent asthma: a 12-week randomized trial
Abstract
Background
Fluticasone furoate (FF) is a novel, once-daily inhaled corticosteroid (ICS) that has been shown to improve lung function vs. placebo in asthma patients. This study evaluated the efficacy and safety of FF 50 mcg compared with placebo in asthma patients uncontrolled by non-ICS therapy.
Methods
This 12-week, multicentre, randomized, double-blind, placebo-controlled, parallel-group, phase III study randomized 248 patients (aged ā„12Ā years) to once-daily FF 50 mcg administered via the ELLIPTAā¢a dry powder inhaler or placebo. The primary endpoint was change from baseline in pre-dose evening trough forced expiratory volume in one second (FEV1). Secondary endpoints were change from baseline in percentage of rescue-free 24-h periods (powered), evening and morning peak expiratory flow, symptom-free 24-h periods and withdrawals due to lack of efficacy. Other endpoints included Asthma Control Testā¢, Asthma Quality of Life Questionnaire and ELLIPTA ease of use questions. Safety was assessed throughout the study.
Results
There was a significant difference in evening trough FEV1 between FF 50 mcg and placebo (treatment difference: 120Ā mL; pā=ā0.012). There was also a significant difference in rescue-free 24-h periods (11.6%; pā=ā0.004) vs. placebo. There were numerically greater improvements with FF vs. placebo for all remaining secondary endpoints. The incidence of adverse events was lower with FF (31%) than with placebo (38%); few were treatment-related (FF 50 mcg: nā=ā1, <1%; placebo: nā=ā4, 3%).
Conclusion
FF 50 mcg once daily significantly improved FEV1 and percentage of rescue-free 24-h periods experienced over 12Ā weeks vs. placebo, and was well tolerated.
Trial registration
www.clinicaltrials.gov
, registration number:
NCT0143607
Cough and its importance in COPD
Patients with COPD most frequently complain of breathlessness and cough and these are both increased during exacerbations. Studies have generally focused on quality of life during end-stage disease, where breathlessness becomes dominant and cough less important. There are very little data on the frequency and severity of cough in COPD or its impact on quality of life at different stages of disease. Little is known about the factors that influence objective cough counts in COPD. Cough may be a marker for progressive disease in milder COPD patients who continue to smoke, and it may be useful in case-finding for milder disease in the community. The cough reflex sensitivity is heightened in COPD compared with healthy volunteers and similar to that in subjects with asthma. The degree of airflow obstruction does not predict cough reflex sensitivity or objective cough counts, implying an independent process. Effective treatments for cough in COPD have not yet been identified. Improved outcome measures of cough, a better understanding of cough in the natural history of COPD, and its importance to patients are needed
- ā¦