60 research outputs found
Effect of geometrical parameters of aluminum-to-steel bolted connections
Abstract : Through experimental and numerical studies, this research work aims to provide directions on the optimal geometric configuration for single-lap and double-lap bolted connection between aluminum alloy 6061-T6 and steel. From experimental test results, the effects of different geometric parameters on the joint strength were discussed. These parameters include the end-distance, the side-distance, the pitch-distance, the plate thickness and the joint eccentricity. Then, the experimental results were compared to predicted results using design references and geometric recommendations proposed by design references were critically examined. The experimental study was complemented by finite element (FE) analysis to extend the study to a larger range of parameters. In addition to the analysis of the geometric parameters listed above, the effects of the gage-distance on the joint strength were studied in the FE analysis. The experimental and finite element results show that a careful selection of geometric parameters can result in the high improvement of the connection strength and failure mode. Limiting the side-distance to the minimum recommended value was found to limit the strength of a connection with two bolts in a column to that of the one-bolt connection. In most cases, bearing was found to govern the strength of the connections. The calculated bearing strengths were found to underestimate significantly the connection strength. Based on these analyses, maximum geometric parameters beyond which there is no further increase of the joint capacity were evaluated and optimum geometric parameters were proposed
Signal acquisition and analysis of ambulatory electromyographic recordings for the assessment of sleep bruxism : A scoping review
Background Ambulatory electromyographic (EMG) devices are increasingly being used in sleep bruxism studies. EMG signal acquisition, analysis and scoring methods vary between studies. This may impact comparability of studies and the assessment of sleep bruxism in patients. Objectives (a) To provide an overview of EMG signal acquisition and analysis methods of recordings from limited-channel ambulatory EMG devices for the assessment of sleep bruxism; and (b) to provide an overview of outcome measures used in sleep bruxism literature utilising such devices. Method A scoping review of the literature was performed. Online databases PubMed and Semantics Scholar were searched for studies published in English until 7 October 2020. Data on five categories were extracted: recording hardware, recording logistics, signal acquisition, signal analysis and sleep bruxism outcomes. Results Seventy-eight studies were included, published between 1977 and 2020. Recording hardware was generally well described. Reports of participant instructions in device handling and of dealing with failed recordings were often lacking. Basic elements of signal acquisition, for example amplifications factors, impedance and bandpass settings, and signal analysis, for example rectification, signal processing and additional filtering, were underreported. Extensive variability was found for thresholds used to characterise sleep bruxism events. Sleep bruxism outcomes varied, but typically represented frequency, duration and/or intensity of masticatory muscle activity (MMA). Conclusion Adequate and standardised reporting of recording procedures is highly recommended. In future studies utilising ambulatory EMG devices, the focus may need to shift from the concept of scoring sleep bruxism events to that of scoring the whole spectrum of MMA.Peer reviewe
Theory and applications of atomic and ionic polarizabilities
Atomic polarization phenomena impinge upon a number of areas and processes in
physics. The dielectric constant and refractive index of any gas are examples
of macroscopic properties that are largely determined by the dipole
polarizability. When it comes to microscopic phenomena, the existence of
alkaline-earth anions and the recently discovered ability of positrons to bind
to many atoms are predominantly due to the polarization interaction. An
imperfect knowledge of atomic polarizabilities is presently looming as the
largest source of uncertainty in the new generation of optical frequency
standards. Accurate polarizabilities for the group I and II atoms and ions of
the periodic table have recently become available by a variety of techniques.
These include refined many-body perturbation theory and coupled-cluster
calculations sometimes combined with precise experimental data for selected
transitions, microwave spectroscopy of Rydberg atoms and ions, refractive index
measurements in microwave cavities, ab initio calculations of atomic structures
using explicitly correlated wave functions, interferometry with atom beams, and
velocity changes of laser cooled atoms induced by an electric field. This
review examines existing theoretical methods of determining atomic and ionic
polarizabilities, and discusses their relevance to various applications with
particular emphasis on cold-atom physics and the metrology of atomic frequency
standards.Comment: Review paper, 44 page
Effective Rheology of Bubbles Moving in a Capillary Tube
We calculate the average volumetric flux versus pressure drop of bubbles
moving in a single capillary tube with varying diameter, finding a square-root
relation from mapping the flow equations onto that of a driven overdamped
pendulum. The calculation is based on a derivation of the equation of motion of
a bubble train from considering the capillary forces and the entropy production
associated with the viscous flow. We also calculate the configurational
probability of the positions of the bubbles.Comment: 4 pages, 1 figur
Interface Cohesive Elements to Model Matrix Crack Evolution in Composite Laminates
In this paper, the transverse matrix (resin) cracking developed in multidirectional composite laminates loaded in tension was numerically investigated by a finite element (FE) model implemented in the commercially available software Abaqus/Explicit 6.10. A theoretical solution using the equivalent constraint model (ECM) of the damaged laminate developed by Soutis et al. was employed to describe matrix cracking evolution and compared to the proposed numerical approach. In the numerical model, interface cohesive elements were inserted between neighbouring finite elements that run parallel to fibre orientation in each lamina to simulate matrix cracking with the assumption of equally spaced cracks (based on experimental measurements and observations). The stress based traction-separation law was introduced to simulate initiation of matrix cracking and propagation under mixed-mode loading. The numerically predicted crack density was found to depend on the mesh size of the model and the material fracture parameters defined for the cohesive elements. Numerical predictions of matrix crack density as a function of applied stress are in a good agreement to experimentally measured and theoretically (ECM) obtained values, but some further refinement will be required in near future work
- …