    Maintenance of bone mineral density after implantation of a femoral neck hip prosthesis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Stress shielding of the proximal femur has been observed in a number of conventional cementless implants used in total hip arthroplasty. Short femoral-neck implants are claiming less interference with the biomechanics of the proximal femur. The goal of this study was to investigate the changes of bone-mineral density in the proximal femur and the clinical outcome after implantation of a short femoral-neck prosthesis.</p> <p>Methods</p> <p>We prospectively assessed the clinical outcome and the changes of bone mineral density of the proximal femur up to one year after implantation of a short femoral neck prosthesis in 20 patients with a mean age of 47 years (range 17 to 65). Clinical outcome was assessed using the Harris Hip Score. The WOMAC was used as a patient-relevant outcome-measure. The bone mineral density was determined using dual energy x-ray absorptiometry, performed 10 days, three months and 12 months after surgery.</p> <p>Results</p> <p>The Harris Hip Score improved from an average preoperative score of 46 to a postoperative score at 12 months of 89 points, the global WOMAC index from 5,3 preoperatively to 0,8 at 12 months postoperatively. In contrast to conventional implants, the DEXA-scans overall revealed a slight increase of bone mineral density in the proximal femur in the 12 months following the implantation.</p> <p>Conclusion</p> <p>The short femoral neck stem lead to a distinct bone reaction. This was significantly different when compared to the changes in bone mineral density reported after implantation of conventional implants.</p

    Predictors of functional outcome following femoral neck fractures treated with an arthroplasty: limitations of the Harris hip score

    Get PDF
    Introduction To study the association between potential prognostic factors and functional outcome at 1 and 5 year follow-up in patients with femoral neck fractures treated with an arthroplasty. To analyze the reliability of the Harris hip score (HHS). Materials and methods A multicenter analysis which included 252 patients who sustained a femoral neck fracture treated with an arthroplasty. Functional outcome after surgery was assessed using a modified HHS and was evaluated after 1 (HHS1) and 5 (HHS5) years. Several prognostic factors were analyzed and reliability of the HHS was assessed. Results After 1 year the presence of co-morbidities was a significant (p = 0.002) predictor for a poor functional outcome (mean HHS1 71.8 with co-morbidities, and 80.6 without co-morbidities). After 5 years none of the potential prognostic factors had significant influence on functional outcome. Internal consistency testing of the HHS showed that when pain and function of the HHS were analyzed together, the internal consistency was poor (HHS1 0.38 and HHS5 0.20). The internal consistency of the HHS solely in function (without pain) improved to 0.68 (HHS1) and 0.46 (HHS5). Analyzing the functional aspect exclusively, age and the existence of co-morbidities could be defined as predictors for functional outcome of femoral neck fractures after 1 and 5 years. Conclusion After using the HHS in a modification, age and the existence of pre-operative co-morbidities appeared to be predictors of the functional outcome after 1 and 5 years. The HHS, omitting pain, is a more reliable score to estimate the functional outcome, than HHS analyzing pain and function in one scoring syste
    corecore