647 research outputs found

    Condensin I Recruitment to Base Damage-Enriched DNA Lesions Is Modulated by PARP1

    Get PDF
    Condensin I is important for chromosome organization and segregation in mitosis. We previously showed that condensin I also interacts with PARP1 in response to DNA damage and plays a role in single-strand break repair. However, whether condensin I physically associates with DNA damage sites and how PARP1 may contribute to this process were unclear. We found that condensin I is preferentially recruited to DNA damage sites enriched for base damage. This process is dictated by PARP1 through its interaction with the chromosome-targeting domain of the hCAP-D2 subunit of condensin I

    Soluble Rhesus Lymphocryptovirus gp350 Protects against Infection and Reduces Viral Loads in Animals that Become Infected with Virus after Challenge

    Get PDF
    Epstein-Barr virus (EBV) is a human lymphocryptovirus that is associated with several malignancies. Elevated EBV DNA in the blood is observed in transplant recipients prior to, and at the time of post-transplant lymphoproliferative disease; thus, a vaccine that either prevents EBV infection or lowers the viral load might reduce certain EBV malignancies. Two major approaches have been suggested for an EBV vaccine- immunization with either EBV glycoprotein 350 (gp350) or EBV latency proteins (e.g. EBV nuclear antigens [EBNAs]). No comparative trials, however, have been performed. Rhesus lymphocryptovirus (LCV) encodes a homolog for each gene in EBV and infection of monkeys reproduces the clinical, immunologic, and virologic features of both acute and latent EBV infection. We vaccinated rhesus monkeys at 0, 4 and 12 weeks with (a) soluble rhesus LCV gp350, (b) virus-like replicon particles (VRPs) expressing rhesus LCV gp350, (c) VRPs expressing rhesus LCV gp350, EBNA-3A, and EBNA-3B, or (d) PBS. Animals vaccinated with soluble gp350 produced higher levels of antibody to the glycoprotein than those vaccinated with VRPs expressing gp350. Animals vaccinated with VRPs expressing EBNA-3A and EBNA-3B developed LCV-specific CD4 and CD8 T cell immunity to these proteins, while VRPs expressing gp350 did not induce detectable T cell immunity to gp350. After challenge with rhesus LCV, animals vaccinated with soluble rhesus LCV gp350 had the best level of protection against infection based on seroconversion, viral DNA, and viral RNA in the blood after challenge. Surprisingly, animals vaccinated with gp350 that became infected had the lowest LCV DNA loads in the blood at 23 months after challenge. These studies indicate that gp350 is critical for both protection against infection with rhesus LCV and for reducing the viral load in animals that become infected after challenge. Our results suggest that additional trials with soluble EBV gp350 alone, or in combination with other EBV proteins, should be considered to reduce EBV infection or virus-associated malignancies in humans

    Efficacy and safety of a subacromial continuous ropivacaine infusion for post-operative pain management following arthroscopic rotator cuff surgery: A protocol for a randomised double-blind placebo-controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Major shoulder surgery often results in severe post-operative pain and a variety of interventions have been developed in an attempt to address this. The continuous slow infusion of a local anaesthetic directly into the operative site has recently gained popularity but it is expensive and as yet there is little conclusive evidence that it provides additional benefits over other methods of post-operative pain management.</p> <p>Methods/Design</p> <p>This will be a randomised, placebo-controlled trial involving 158 participants. Following diagnostic arthroscopy, all participants will undergo arthroscopic subacromial decompression with or without rotator cuff repair, all operations performed by a single surgeon. Participants, the surgeon, nurses caring for the patients and outcome assessors will be blinded to treatment allocation. All participants will receive a pre-incision bolus injection of 20 mls of ropivacaine 1% into the shoulder and an intra-operative intravenous bolus of parecoxib 40 mg. Using concealed allocation participants will be randomly assigned to active treatment (local anaesthetic ropivacaine 0.75%) or placebo (normal saline) administered continuously into the subacromial space by an elastomeric pump at 5 mls per hour post-operatively. Patient controlled opioid analgesia and oral analgesics will be available for breakthrough pain. Outcome assessment will be at 15, 30 and 60 minutes, 2, 4, 8, 12, 18 and 24 hours, and 2 or 4 months for decompression or decompression plus repair respectively.</p> <p>The primary end point will be average pain at rest over the first 12-hour post-operative period on a verbal analogue pain score. Secondary end points will be average pain at rest over the second 12-hour post-operative period, maximal pain at rest over the first and second 12-hour periods, amount of rescue medication used, length of inpatient stay and incidence of post-operative adhesive capsulitis.</p> <p>Discussion</p> <p>The results of this trial will contribute to evidence-based recommendations for the effectiveness of pain management modalities following arthroscopic rotator cuff surgery. If the local anaesthetic pain-buster provides no additional benefits over placebo then valuable resources can be put to better use in other ways.</p> <p>Trial registration</p> <p>Australian Clinical Trials Register Number ACTR12606000195550</p

    A geometric analysis of hallux valgus: correlation with clinical assessment of severity

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Application of plane geometry to the study of bunion deformity may represent an interesting and novel approach in the research field of hallux valgus. For the purpose of contributing to development of a different perspective in the assessment of hallux valgus, this study was conducted with three objectives: a) to determine the position on the intersection point of the perpendicular bisectors of the longitudinal axes of the first metatarsal and proximal phalanx (IP), b) to correlate the location of this point with hallux valgus deformity according to angular measurements and according to visual assessment of the severity carried out by three independent observers, and c) to assess whether this IP correlated with the radius of the first metatarsophalangeal arc circumference.</p> <p>Methods</p> <p>Measurements evaluated were intermetatarsal angle (IMA), hallux valgus angle (HVA), and proximal phalangeal articular angle (PPAA). The Autocad<sup>Âź </sup>program computed the location of the IP inside or outside of the foot. Three independent observers rated the severity of hallux valgus in photographs using a 100-mm visual analogue scale (VAS).</p> <p>Results</p> <p>Measurements of all angles except PPAA showed significantly lower values when the IP was located out of the foot more distantly and vice versa, significantly higher values for severe deformities in which the IP was found inside the foot (<it>p </it>< 0.001). The IP correlated significantly with VAS scores and with the length of the radius of the circle that included the first metatarsophalangeal arc circumference (<it>p </it>< 0.001)</p> <p>Conclusion</p> <p>The IP is a useful indicator of hallux valgus deformity because correlated significantly with IMA and HVA measurements, VAS scores obtained by visual inspection of the degree of deformity, and location of the center of the first metatarsophalangeal arc circumference.</p

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Measurement of the Z/gamma* + b-jet cross section in pp collisions at 7 TeV

    Get PDF
    The production of b jets in association with a Z/gamma* boson is studied using proton-proton collisions delivered by the LHC at a centre-of-mass energy of 7 TeV and recorded by the CMS detector. The inclusive cross section for Z/gamma* + b-jet production is measured in a sample corresponding to an integrated luminosity of 2.2 inverse femtobarns. The Z/gamma* + b-jet cross section with Z/gamma* to ll (where ll = ee or mu mu) for events with the invariant mass 60 < M(ll) < 120 GeV, at least one b jet at the hadron level with pT > 25 GeV and abs(eta) < 2.1, and a separation between the leptons and the jets of Delta R > 0.5 is found to be 5.84 +/- 0.08 (stat.) +/- 0.72 (syst.) +(0.25)/-(0.55) (theory) pb. The kinematic properties of the events are also studied and found to be in agreement with the predictions made by the MadGraph event generator with the parton shower and the hadronisation performed by PYTHIA.Comment: Submitted to the Journal of High Energy Physic

    Increased Incidence of Choroid Plexus Carcinoma Due to the Germline TP53 R337H Mutation in Southern Brazil

    Get PDF
    International audienceBACKGROUND: Choroid plexus carcinomas (CPC) are rare tumors predominantly found in children. Given the high frequency of the germline R337H mutation in the TP53 gene in southern Brazil, we have evaluated the frequency of the R337H mutation in families with CPC in children. METHODOLOGY/PRINCIPAL FINDINGS: The present series included 29 patients that were admitted to the same institution from 1992 to 2010, including 22 children with CPC (0.08-13.6 years of age at diagnosis) and 7 children with papilloma of the choroid plexus (Pp; 0.5-9.8 years of age). Surgical resection was possible in 28 children. Blood and/or tumor DNA was extracted and analyzed using PCR-RFLP and results were confirmed by sequencing 240 bp of the TP53 exon 10. The patients, all parents, and some relatives submitted samples for blood DNA analysis. In addition, we have also examined the presence of the mutation in DNA from paraffin-embedded tumor samples to evaluate loss of heterozygosity. We found 63.3% (14/22) of the CPC patients positive for the germline R337H mutation; CPC samples were either heterozygous (n = 7), lost only the wild-type (n = 4), or only the R337H copy (n = 2). One CPC sample was not available. All Pp cases (7/7, 100%) were negative for R337H. Cure (>5 years survival free of disease) was observed in 18.1% of the CPC cases with the R337H mutation (2/11), 71.4% of the Pp (5/7), and 25% of CPC cases negative for the R337H mutation (2/8). Family history of cancer (with 2 or more cancer cases) was exclusively identified on the parental side segregating the R337H mutation, and 50% (7/14) of them were compatible with Li-Fraumeni-like syndrome. SIGNIFICANCE: Our results show for the first time that the R337H TP53 mutation is responsible for 63% of the CPC cases in children, suggesting a higher incidence of CPC in southern Brazil
    • 

    corecore