163 research outputs found

    Pectus Excavatum and Risk of Right Ventricular Failure in Left Ventricular Assist Device Patients

    Get PDF
    Background: Right ventricular failure (RVF) is a significant cause of morbidity and mortality in patients with a left ventricular assist device (LVAD). This study is aimed to investigate the influence of a pectus excavatum on early and late outcomes, specifically RVF, following LVAD implantation. Methods: A retrospective study was performed, that included patients with a HeartMate 3 LVAD at our tertiary referral center. The Haller index (HI) was calculated using computed tomography (CT) scan to evaluate the chest-wall dimensions. Results: In total, 80 patients (median age 57 years) were included. Two cohorts were identified: 28 patients (35%) with a normal chest wall (HI &lt;2.0) and 52 patients (65%) with pectus excavatum (HI 2.0-3.2), with a mean follow-up time of 28 months. Early (&lt;30 days) RVF and early acute kidney injury events did not differ between cohorts. Overall survival did not differ between cohorts with a hazard ratio (HR) of 0.47 (95% confidence interval (CI): 0.19-1.19, p = 0.113). Late (&gt;30 days) recurrent readmission for RVF occurred more often in patients with pectus excavatum (p = 0.008). The onset of late RVF started around 18 months after implantation and increased thereafter in the overall study cohort.Conclusions: Pectus excavatum is observed frequently in patients with a LVAD implantation. These patients have an increased rate of readmissions and late RVF. Further investigation is required to explore the extent and severity of chest-wall abnormalities on the risk of RVF.</p

    Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices

    Get PDF
    AIMS: To investigate the prevalence of electromagnetic interference (EMI) between left ventricular assist devices (LVADs) and implantable cardioverter-defibrillators (ICDs)/pacemakers (PMs). METHODS AND RESULTS: A retrospective single-centre study was conducted, including all patients undergoing HeartMate II (HMII) and HeartMate 3 (HM3) LVAD implantation (n = 106). Electromagnetic interference was determined by the inability to interrogate the ICD/PM. Overall, 85 (mean age 59 ± 8, 79% male) patients had an ICD/PM at the time of LVAD implantation; 46 patients with HMII and 40 patients with HM3. Among the 85 LVAD patients with an ICD's/PM's, 11 patients (13%) experienced EMI; 6 patients (15%) with an HMII and 5 patients (11%) with an HM3 (P = 0.59). Electromagnetic interference from the HMII LVADs was only present in patients with a St Jude/Abbott device; 6 of the 23 St Jude/Abbott devices. However, in the HM3 patients, EMI was mainly present in patients with Biotronik devices: 4 of the 18 with only one (1/25) patient with a Medtronic device. While initial interrogation of these devices was not successful, none of the 11 cases experienced pacing inhibition or inappropriate shocks. CONCLUSION: In summary, the prevalence of EMI between ICDs in the older and newer type of LVAD's remains rather high. While HMII patients experienced EMI with a St Jude/Abbott device (which was already known), HM3 LVAD patients experience EMI mainly with Biotronik devices. Prospective follow-up, preferably in large registries, is warranted to investigate the overall prevalence and impact of EMI in LVAD patients

    Survival following a concomitant aortic valve procedure during left ventricular assist device surgery: an ISHLT Mechanically Assisted Circulatory Support (IMACS) Registry analysis

    Get PDF
    Aims The aim of this study was to compare early- and late-term survival and causes of death between patients with and without a concomitant aortic valve (AoV) procedure during continuous-flow left ventricular assist device (LVAD) surgery. Methods and results All adult primary continuous-flow LVAD patients on the International Society of Heart and Lung Transplantation (ISHLT) Mechanically Assisted Circulatory Support (IMACS) Registry (n = 15 267) were included in this analysis and stratified into patients submitted to a con

    Modification of a Ventricular Assistance Device for a Hemiplegic Left Ventricular Assist Device Patient

    Get PDF
    Neurologic events occur in up to 18% of patients with continuous-flow left ventricular assist devices (LVAD) and is associated with significant morbidity and mortality. The current form of the LVAD equipment is not suited to serve patients who are impaired by a stroke. By creating an assistance device for the LVAD equipment, we have been able to greatly improve the quality of life and self-dependence of a hemiplegic LVAD patient

    Integrating genetic and gene expression data: application to cardiovascular and metabolic traits in mice

    Get PDF
    The millions of common DNA variations that occur in the human population, or among inbred strains of mice and rats, perturb the expression (transcript levels) of a large fraction of the genes expressed in a particular tissue. The hundreds or thousands of common cis-acting variations that occur in the population may in turn affect the expression of thousands of other genes by affecting transcription factors, signaling molecules, RNA processing, and other processes that act in trans. The levels of transcripts are conveniently quantitated using expression arrays, and the cis- and trans-acting loci can be mapped using quantitative trait locus (QTL) analysis, in the same manner as loci for physiologic or clinical traits. Thousands of such expression QTL (eQTL) have been mapped in various crosses in mice, as well as other experimental organisms, and less detailed maps have been produced in studies of cells from human pedigrees. Such an integrative genetics approach (sometimes referred to as “genetical genomics”) is proving useful for identifying genes and pathways that contribute to complex clinical traits. The coincidence of clinical trait QTL and eQTL can help in the prioritization of positional candidate genes. More importantly, mathematical modeling of correlations between levels of transcripts and clinical traits in genetic crosses can allow prediction of causal interactions and the identification of “key driver” genes. An important objective of such studies will be to model biological networks in physiologic processes. When combined with high-density single nucleotide polymorphism (SNP) mapping, it should be feasible to identify genes that contribute to transcript levels using association analysis in outbred populations. In this review we discuss the basic concepts and applications of this integrative genomic approach to cardiovascular and metabolic diseases

    Impact of Continuous Flow Left Ventricular Assist Device Therapy on Chronic Kidney Disease: A Longitudinal Multicenter Study

    Get PDF
    Background: Many patients undergoing durable left ventricular assist device (LVAD) implantation suffer from chronic kidney disease (CKD). Therefore, we investigated the effect of LVAD support on CKD. Methods: A retrospective multicenter cohort study, including all patients undergoing LVAD (HeartMate II (n = 330), HeartMate 3 (n = 22) and HeartWare (n = 48) implantation. In total, 227 (56.8%) patients were implanted as bridge-to-transplantation; 154 (38.5%) as destination therapy; and 19 (4.7%) as bridge-to-decision. Serum creatinine measurements were collected over a 2-year follow-up period. Patients were stratified based on CKD stage. Results: Overall, 400 patients (mean age 53 ± 14 years, 75% male) were included: 186 (46.5%) patients had CKD stage 1 or 2; 93 (23.3%) had CKD stage 3a; 82 (20.5%) had CKD stage 3b; and 39 (9.8%) had CKD stage 4 or 5 prior to LVAD implantation. During a median follow-up of 179 days (IQR 28–627), 32,629 creatinine measurements were available. Improvement of kidney function was noticed in every preoperative CKD-stage group. Following this improvement, estimated glomerular filtration rates regressed to baseline values for all CKD stages. Patients showing early renal function improvement were younger and in worse preoperative condition. Moreover, survival rates were higher in patients showing early improvement (69% vs 56%, log-rank P = 0.013). Conclusions: Renal function following LVAD implantation is characterized by improvement, steady state and subsequent deterioration. Patients who showed early renal function improvement were in worse preoperative condition, however, and had higher survival rates at 2 years of follow-up