18,269 research outputs found

    Proton irradiation of e2v technologies L3Vision devices

    Get PDF
    This paper describes the proton irradiation and subsequent analysis of 8 e2v technologies CCD65 L3Vision devices with the intention of assessing the suitability of L3Vision technology to applications in space. In particular the use of L3Vision charge coupled devices (CCDs) on the Radial Velocity Spectrometer (RVS) instrument of the planned European Space Agency GAIA mission is discussed. The operational properties of the devices were characterised before irradiation with protons to a 10 MeV equivalent fluence of 2.5 × 109 protons cm-2. The devices were then characterised again before undergoing a second proton irradiation which increased the total 10 MeV equivalent proton fluence received by each device to 2.1 × 1010 protons cm-2. All 8 devices functioned as expected after each irradiation, with no catastrophic failures occurring even after the second irradiation which increased the total proton fluence to approximately 10 times the expected 6 year RVS fluence

    The effect of protons on E2V technologies L3Vision CCDs

    Get PDF
    The effect of different 10 MeV equivalent proton fluences on the performance of E2V Technologies (formerly Marconi applied technologies, formerly EEV) L3Vision Charge Coupled Devices (CCDs) was investigated. The first experimental radiation damage results of the L3Vision device are presented, with emphasis given to the analysis of damage to the gain register of the device. Changes in dark current and generation of bright pixels in the CCD image, store, readout register and gain register as a result of proton irradiation are reported and viewed in light of the potential use of the device in space-based applications

    Random telegraph signals in charge coupled devices

    Get PDF
    An investigation of fluctuating pixels resulting from proton irradiation of an E2V Technologies CCD47-20 device is presented. The device structure,experimental set up and irradiation methodology are described, followed by a detailed analysis of radiation induced random telegraph signals,RTS. The characteristics of the observed flickering pixels are discussed in detail and the proposed models explaining the mechanism behind the phenomena are viewed in light of the collected data

    Proton irradiation of EMCCDs

    Get PDF
    This paper describes the irradiation of 95 electron multiplication charge coupled devices (EMCCDs) at the Paul Scherrer Institut (PSI) in Switzerland, to investigate the effects of proton irradiation on the operational characteristics of CCDs featuring electron multiplication technology for space use. This work was carried out in support of the CCD development for the radial velocity spectrometer (RVS) instrument of the European Space Agency's cornerstone Gaia mission. Previous proton irradiations of EMCCDs, have shown the technology to be radiation hard to /spl sim/10/spl times/ the required six-year Gaia lifetime proton fluence, with no device failures or unexpected operational changes. The purpose of the study described in this paper was to further investigate the statistical probability of device failure as a result of radiation damage, the large number of devices and high proton fluence used, making the study equivalent to testing /spl sim/50 complete RVS CCD focal planes to the expected end of life proton dose. An outline of the earlier EMCCD proton irradiations is given, followed by a detailed description of the proton irradiation and characterization of the 95 devices used in this latest study

    On A. D. Smith's constancy based defence of direct realism

    Get PDF
    This paper presents an argument against A D Smith's Direct Realist theory of perception, which attempts to defend Direct Realism against the argument from illusion by appealing to conscious perceptual states that are structured by the perceptual constancies. Smith's contention is that the immediate objects of perceptual awareness are characterised by these constancies, which removes any difficulty there may be in identifying them with the external, or normal, objects of awareness. It is here argued that Smith's theory does not provide an adequate defence of Direct Realism because it does not adequately deal with the difficulties posed by the possibility of perceptual illusion. It is argued that there remain possible illusory experiences where the immediate objects of awareness, which in Smith's account are those characterised by perceptual constancies, cannot be identified with the external objects of awareness, contrary to Direct Realism. A further argument is offered to extend this conclusion to all non-illusory cases, by adapting an argument of Smith's own for the generalising step of the Argument from Illusion. The result is that Smith's theory does not provide an adequate Direct Realist account of the possibility of perceptual illusion. © 2011 Springer Science+Business Media B.V

    Proton induced leakage current in CCDs

    Get PDF
    The effect of different proton fluences on the performance of two E2V Technologies CCD47-20 devices was investigated with particular emphasis given to the analysis of 'random telegraph signal' (RTS) generation, bright pixel generation and induced changes in base dark current level. The results show that bright pixel frequency increases as the mean energy of the proton beam is increased, and that the base dark current level after irradiation scales with the level of ionization damage. For the RTS study, 500 pixels on one device were monitored over a twelve hour period. This data set revealed a number of distinct types of pixel change level fluctuation and a system of classification has been devised. Previously published RTS data is discussed and reviewed in light of the new data

    Proton ordering in Antarctic ice

    Get PDF

    EMCCDs for space applications

    Get PDF
    This paper describes a qualification programme for Electron-Multiplication Charge Coupled Devices (EMCCDs) for use in space applications. While the presented results are generally applicable, the programme was carried out in the context of CCD development for the Radial Velocity Spectrometer (RVS) instrument on the European Space Agency's cornerstone Gaia mission. We discuss the issues of device radiation tolerance, charge transfer efficiency at low signal levels and life time effects on the electron-multiplication gain. The development of EMCCD technology to allow operation at longer wavelengths using high resistivity silicon, and the cryogenic characterisation of EMCCDs are also described

    Application of electron multiplying CCD technology in space instrumentation

    Get PDF
    Electron multiplying CCD (EMCCD) technology has found important initial applications in low light surveillance and photon starved scientific instrumentation. This paper discusses the attributes of the EMCCD which make it useful for certain space instruments, particularly those which are photon starved, and explores likely risks from the radiation expected in such instruments

    Development and Testing of a 2-D Transfer CCD

    Get PDF
    This paper describes the development, operation, and characterization of charge-coupled devices (CCDs) that feature an electrode structure that allows the transfer of charge both horizontally and vertically through the image area. Such devices have been termed two-dimensional (2-D) transfer CCDs (2DT CCDs), as opposed to the conventional devices, which might be called one-dimensional transfer CCDs, but in other respects are the same as conventional CCD devices. Batches of two different 2DT CCD test devices, featuring different electrode structures but with identical clocking operation in each case, were produced and tested. The methodology of 2-D charge transfer in each of the device types is described, followed by a presentation of test results from the new CCDs. The ability of both 2DT CCD transfer electrode schemes to successfully transfer charge in both horizontal and vertical directions in the image section of the devices has been proven, opening up potential new applications for 2DT CCD use
    corecore