17 research outputs found

    Comparison of mechanical rigidity between plate augmentation leaving the nail in situ and interlocking nail using cadaveric fracture model of the femur

    No full text
    Thirteen matched pairs of cadaveric femurs were placed into two groups. In each group, a transverse fracture was created at a point 70% distal between the lesser trochanter and the adductor tubercle. One femur out of each matched pair was then stabilised with an interlocking intramedullary nail (nail only group) and the other femur was stabilised with plate augmentation after interlocking intramedullary nailing (plate augmentation group). The bending load to promote 5-mm displacement showed statistically significant differences between the plate augmentation group (mean 843.36 ± 409.13 N) and the nail only group (mean 315.02 ± 219.80 N) (p = 0.001). Torsional torque at the angle of 15 degrees showed statistically significant differences between the two groups; a mean of 2.09 ± 0.53 N·m for the plate augmentation group and a mean of 0.63 ± 0.46 N·m for the nail only group (p = 0.0001). We found a 2.6-fold increase in bending stiffness and a 3.3-fold increase in torsional stiffness in plate augmentation leaving a nail in situ compared to interlocking nailing only in the distal third fracture of femur

    Less is more: lag screw only fixation of lateral malleolar fractures

    No full text
    Displaced fractures of the lateral malleolus are typically treated with plate osteosynthesis with or without the use of lag screws, and immobilisation in a plaster cast for up to 6 weeks. Fixation through a smaller incision with less metal, such as lag screw only fixation, would theoretically lead to decreased infection rates and less irritation caused by hardware. The purpose of this study was to evaluate the benefits and success of lag screw only fixation of the lateral malleolus in non-comminuted oblique fractures of the lateral malleolus. A total of 25 patients who had non-comminuted unstable oblique fractures of their lateral malleolus that had been surgically fixed with lag screws only were retrospectively evaluated. All patients were younger than 60 years of age. Evaluation of the success of fixation, complications, resultant mobility and patient satisfaction was based on information gathered from chart reviews, X-ray findings and a standardised questionnaire based on the AOFAS Foot and Ankle Outcomes Questionnaire. These results were compared to an age-matched group of 25 consecutive patients treated with plate osteosynthesis. Of the 25 patients fixed with lag screws, nine had an unstable fracture of the lateral malleolus only, ten were bimalleolar fractures and six were trimalleolar. Eighteen patients were treated with two lag screws, and seven were treated with three lag screws. The bi- and trimalleolar fractures were treated with standard partially threaded cancellous screws. None of the lag screw-only group lost reduction. There were no documented wound infections in the lag screw group as compared to three deep infections in the plate group. Lag screw-only patients reported no palpable hardware as compared to 50% of the plate group. AOFAS scores at a mean of 12 months post-operative were similar in both groups. Lag screw only fixation of the lateral malleolus is a safe and effective method that has a number of advantages over plate osteosynthesis, in particular less soft tissue dissection, less prominent, symptomatic and palpable hardware and a reduced requirement for secondary surgical removal

    Wear Mechanisms in Ceramic Hip Implants

    Get PDF
    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in-vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metalon- polyethylene combinations
    corecore