159 research outputs found
Viewing Chord Dependence of Effective High Energy Proton Temperature Teff during ICRF Heating on LHD
Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator
Various neutron diagnostic tools are used in fusion reactors to evaluate
different aspects of plasma performance, such as fusion power, power density,
ion temperature, fast ion energy, and their spatial distributions. The stilbene
scintillator has been proposed for use as a neutron diagnostic system to
measure the characteristics of neutrons from the Korea Superconducting Tokamak
Advanced Research (KSTAR) fusion reactor. Specially designed electronics are
necessary to measure fast neutron spectra with high radiation from a gamma-ray
background. The signals from neutrons and gamma-rays are discriminated by the
digital charge pulse shape discrimination (PSD) method, which uses total to
partial charge ratio analysis. The signals are digitized by a flash
analog-to-digital convertor (FADC). To evaluate the performance of the
fabricated stilbene neutron diagnostic system, the efficiency of 10 mm
soft-iron magnetic shielding and the detection efficiency of fast neutrons were
tested experimentally using a 252Cf neutron source. In the results, the
designed and fabricated stilbene neutron diagnostic system performed well in
discriminating neutrons from gamma-rays under the high magnetic field
conditions during KSTAR operation. Fast neutrons of 2.45 MeV were effectively
measured and evaluated during the 2011 KSTAR campaign.Comment: 15 pages, 14 figures, conferenc
Charge exchange neutral particle analysis with natural diamond detectors on LHD heliotron
Semiconductor detectors based on natural diamonds have been installed on the Large Helical Device (LHD) heliotron to measure the energy distribution of charge exchange fast neutral particles from different viewing angles. Advantages of a natural diamond detector (NDD) are (1) very compact size, (2) relatively easy handling, and (3) high energy resolution. Although NDDs are sensitive to visible light, vacuum ultraviolet, and soft x rays, unfavorable pulses produced by such radiation were greatly reduced by choosing an appropriate stainless steel shield in this experiment. In LHD, the time-resolved energy distribution of counter-going beam ions and ion cyclotron range of frequency-produced energetic ions have been successfully obtained by means of an NDD. The performance of NDDs as a neutral particle analyzer and its good suitability to LHD plasmas were demonstrated throughout this work
- …