159 research outputs found

    Fast Neutron Detector for Fusion Reactor KSTAR Using Stilbene Scintillator

    Full text link
    Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene scintillator has been proposed for use as a neutron diagnostic system to measure the characteristics of neutrons from the Korea Superconducting Tokamak Advanced Research (KSTAR) fusion reactor. Specially designed electronics are necessary to measure fast neutron spectra with high radiation from a gamma-ray background. The signals from neutrons and gamma-rays are discriminated by the digital charge pulse shape discrimination (PSD) method, which uses total to partial charge ratio analysis. The signals are digitized by a flash analog-to-digital convertor (FADC). To evaluate the performance of the fabricated stilbene neutron diagnostic system, the efficiency of 10 mm soft-iron magnetic shielding and the detection efficiency of fast neutrons were tested experimentally using a 252Cf neutron source. In the results, the designed and fabricated stilbene neutron diagnostic system performed well in discriminating neutrons from gamma-rays under the high magnetic field conditions during KSTAR operation. Fast neutrons of 2.45 MeV were effectively measured and evaluated during the 2011 KSTAR campaign.Comment: 15 pages, 14 figures, conferenc

    Charge exchange neutral particle analysis with natural diamond detectors on LHD heliotron

    Get PDF
    Semiconductor detectors based on natural diamonds have been installed on the Large Helical Device (LHD) heliotron to measure the energy distribution of charge exchange fast neutral particles from different viewing angles. Advantages of a natural diamond detector (NDD) are (1) very compact size, (2) relatively easy handling, and (3) high energy resolution. Although NDDs are sensitive to visible light, vacuum ultraviolet, and soft x rays, unfavorable pulses produced by such radiation were greatly reduced by choosing an appropriate stainless steel shield in this experiment. In LHD, the time-resolved energy distribution of counter-going beam ions and ion cyclotron range of frequency-produced energetic ions have been successfully obtained by means of an NDD. The performance of NDDs as a neutral particle analyzer and its good suitability to LHD plasmas were demonstrated throughout this work
    corecore