341 research outputs found

    First report of the occurrence of Phaelota Jacoby, 1887 in Borneo with a description of a new species

    Get PDF
    Phaelota Jacoby, 1887 is reported from Borneo for the first time and a new species, P. kerzhneri sp. n. is describe

    Search for light pseudoscalar sgoldstino in K- decays

    Get PDF
    A search for the light pseudoscalar sgoldstino production in the three body K- decay K-->pipi0P has been performed with the ISTRA+ detector exposed to the 25 GeV negative secondary beam of the U70 proton synchrotron. No signal is seen. An upper limit for the branching ratio Br(K->pipi0P), at 90% confidence level, is found to be around 9*10**-6 in the effective mass m(P) range from 0 till 200 MeV, excluding the region near m(pi0) where it degrades to 3.5*10**-5.Comment: 10 pages, LATEX, 8 EPS figures, revised version, to be published in Phys.Lett.

    High statistic measurement of the K- -> pi0 e- nu decay form-factors

    Full text link
    The decay K- -> pi0 e- nu is studied using in-flight decays detected with the ISTRA+ spectrometer. About 920K events are collected for the analysis. The lambda+ slope parameter of the decay form-factor f+(t) in the linear approximation (average slope) is measured: lambda+(lin)= 0.02774 +- 0.00047(stat) +- 0.00032(syst). The quadratic contribution to the form-factor was estimated to be lambda'+ = 0.00084 +- 0.00027(stat) +- 0.00031(syst). The linear slope, which has a meaning of df+(t)/dt|_{t=0} for this fit, is lambda+ = 0.02324 +- 0.00152(stat) +- 0.00032(syst). The limits on possible tensor and scalar couplings are derived: f_{T}/f_{+}(0)=-0.012 +- 0.021(stat) +- 0.011$(syst), f_{S}/f_{+}(0)=-0.0037^{+0.0066}_{-0.0056}(stat) +- 0.0041(syst).Comment: 11 pages, 8 figures. Accepted by Phys.Lett.

    Measurement of the Dalitz plot slope parameters for K- -> pi0 pi0 pi- decay using ISTRA+ detector

    Get PDF
    The Dalitz plot slope parameters g, h and k for the K- -> pi0 pi0 pi- decay have been measured using in-flight decays detected with the ISTRA+ setup operating in the 25 GeV negative secondary beam of the U-70 PS. About 252 K events with four-momenta measured for the pi- and four involved photons were used for the analysis. The values obtained g=0.627+/-0.004(stat)+/-0.010(syst), h=0.046+/-0.004(stat)+/-0.012(syst), k=0.001+/-0.001(stat)+/-0.002(syst) are consistent with the world averages dominated by K+ data, but have significantly smaller errors.Comment: LaTeX, 10 pages, 8 eps-figures, update of IHEP 2002-1

    Development of a Momentum Determined Electron Beam in the 1 -45 GeV Range

    Get PDF
    A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging system based on drift chambers with 160 micron resolution was able to measure relative electron beam momentum precisely. The resolution sigma_p p was 0.13% at 45 GeV where multiple scattering is negligible. This test beam setup provided the possibility to study properties of lead tungstate crystals (PbWO_4) for the BTeV experiment at Fermilab.Comment: 12 pages, 8 figures; work done by the BTeV Electromagnetic Calorimeter grou

    Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV

    Full text link
    The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons is Delta{E}/E=2.8%/\sqrt{E} + 1.3%. The position resolution for electrons is Delta{x}=3.1 + 15.4/sqrt{E} mm in the center of the cell. The lateral non-uniformity of the prototype energy response to electrons and MIPs has turned out to be negligible. Obtained experimental results are in a good agreement with Monte-Carlo simulations.Comment: Article is prepared for pdflatex using the class elsart. 13 pages, 9 figures in 11 PDF file

    Comparison of Radiation Damage in Lead Tungstate Crystals under Pion and Gamma Irradiation

    Full text link
    Studies of the radiation hardness of lead tungstate crystals produced by the Bogoroditsk Techno-Chemical Plant in Russia and the Shanghai Institute of Ceramics in China have been carried out at IHEP, Protvino. The crystals were irradiated by a 40-GeV pion beam. After full recovery, the same crystals were irradiated using a 137Cs^{137}Cs Îł\gamma-ray source. The dose rate profiles along the crystal length were observed to be quite similar. We compare the effects of the two types of radiation on the crystals light output.Comment: 10 pages, 8 figures, Latex 2e, 28.04.04 - minor grammatical change

    Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals

    Full text link
    Radiation damage in lead tungstate crystals reduces their transparency. The calibration that relates the amount of light detected in such crystals to incident energy of photons or electrons is of paramount importance to maintaining the energy resolution the detection system. We report on tests of lead tungstate crystals, read out by photomultiplier tubes, exposed to irradiation by monoenergetic electron or pion beams. The beam electrons themselves were used to measure the scintillation light output, and a blue light emitting diode (LED) was used to track variations of crystals transparency. We report on the correlation of the LED measurement with radiation damage by the beams and also show that it can accurately monitor the crystals recovery from such damage.Comment: 9 pages, 6 figures, LaTeX2

    LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype

    Full text link
    We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at Protvino, Russia.Comment: 12 pages, 8 figures, LaTeX2e, revised versio

    Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter

    Full text link
    A highly stable monitoring system based on blue and red light emitting diodes coupled to a distribution network comprised of optical fibers has been developed for an electromagnetic calorimeter that uses lead tungstate crystals readout with photomultiplier tubes. We report of the system prototype design and on the results of laboratory tests. Stability better than 0.1% (r.m.s.) has been achieved during one week of prototype operation.Comment: 10 pages, 6 figures, LaTeX2
    • …
    corecore