88 research outputs found
Measurement of and between 3.12 and 3.72 GeV at the KEDR detector
Using the KEDR detector at the VEPP-4M collider, we have measured
the values of and at seven points of the center-of-mass
energy between 3.12 and 3.72 GeV. The total achieved accuracy is about or
better than at most of energy points with a systematic uncertainty of
about . At the moment it is the most accurate measurement of in
this energy range
New precise determination of the \tau lepton mass at KEDR detector
The status of the experiment on the precise lepton mass measurement
running at the VEPP-4M collider with the KEDR detector is reported. The mass
value is evaluated from the cross section behaviour around the
production threshold. The preliminary result based on 6.7 pb of data is
MeV. Using 0.8 pb of data
collected at the peak the preliminary result is also obtained:
eV.Comment: 6 pages, 8 figures; The 9th International Workshop on Tau-Lepton
Physics, Tau0
Search for narrow resonances in e+ e- annihilation between 1.85 and 3.1 GeV with the KEDR Detector
We report results of a search for narrow resonances in e+ e- annihilation at
center-of-mass energies between 1.85 and 3.1 GeV performed with the KEDR
detector at the VEPP-4M e+ e- collider. The upper limit on the leptonic width
of a narrow resonance Gamma(R -> ee) Br(R -> hadr) < 120 eV has been obtained
(at 90 % C.L.)
Measurement of \Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-) and \Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)
The products of the electron width of the J/\psi meson and the branching
fraction of its decays to the lepton pairs were measured using data from the
KEDR experiment at the VEPP-4M electron-positron collider. The results are
\Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-)=(0.3323\pm0.0064\pm0.0048) keV,
\Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)=(0.3318\pm0.0052\pm0.0063) keV.
Their combinations
\Gamma_{ee}\times(\Gamma_{ee}+\Gamma_{\mu\mu})/\Gamma=(0.6641\pm0.0082\pm0.0100)
keV,
\Gamma_{ee}/\Gamma_{\mu\mu}=1.002\pm0.021\pm0.013 can be used to improve
theaccuracy of the leptonic and full widths and test leptonic universality.
Assuming e\mu universality and using the world average value of the lepton
branching fraction, we also determine the leptonic \Gamma_{ll}=5.59\pm0.12 keV
and total \Gamma=94.1\pm2.7 keV widths of the J/\psi meson.Comment: 7 pages, 6 figure
Measurement of main parameters of the \psi(2S) resonance
A high-precision determination of the main parameters of the \psi(2S)
resonance has been performed with the KEDR detector at the VEPP-4M e^{+}e^{-}
collider in three scans of the \psi(2S) -- \psi(3770) energy range. Fitting the
energy dependence of the multihadron cross section in the vicinity of the
\psi(2S) we obtained the mass value
M = 3686.114 +- 0.007 +- 0.011 ^{+0.002}_{-0.012} MeV and the product of the
electron partial width by the branching fraction into hadrons \Gamma_{ee}*B_{h}
= 2.233 +- 0.015 +- 0.037 +- 0.020 keV.
The third error quoted is an estimate of the model dependence of the result
due to assumptions on the interference effects in the cross section of the
single-photon e^{+}e^{-} annihilation to hadrons explicitly considered in this
work.
Implicitly, the same assumptions were employed to obtain the charmonium
leptonic width and the absolute branching fractions in many experiments.
Using the result presented and the world average values of the electron and
hadron branching fractions, one obtains the electron partial width and the
total width of the \psi(2S):
\Gamma_{ee} =2.282 +- 0.015 +- 0.038 +- 0.021 keV,
\Gamma = 296 +- 2 +- 8 +- 3 keV.
These results are consistent with and more than two times more precise than
any of the previous experiments
Exciton-thermal analysis of nonisothermal nucleation in solid solution of CuCl in glass
The work presents results of investigation of nucleation of CuCl nanocrystals in glass by method of exiton-thermal analysis (ETA) which is based on measuring the optical absorbance of CuCl phase in sample under heating up to the melting temperature of CuCl nanocrystals. The melting temperature of nanoparticle depends on its radius. Therefore analysis of curve of melting CuCl phase allows to determine distribution curve of nanoparticles on their radii. By the method of ETA the features of variation of CuCl nanoparticles distributions in glass when changing regime of sample annealing (nonisothermal nucleation) were studied. For example, by reducing the heating rate of the sample the concentration of particles of CuCl phase increases considerably while reducing average radius
Exciton-thermal analysis of nonisothermal nucleation in solid solution of CuCl in glass
The work presents results of investigation of nucleation of CuCl nanocrystals in glass by method of exiton-thermal analysis (ETA) which is based on measuring the optical absorbance of CuCl phase in sample under heating up to the melting temperature of CuCl nanocrystals. The melting temperature of nanoparticle depends on its radius. Therefore analysis of curve of melting CuCl phase allows to determine distribution curve of nanoparticles on their radii. By the method of ETA the features of variation of CuCl nanoparticles distributions in glass when changing regime of sample annealing (nonisothermal nucleation) were studied. For example, by reducing the heating rate of the sample the concentration of particles of CuCl phase increases considerably while reducing average radius
- …