5 research outputs found

    Evidence for PTGER4, PSCA, and MBOAT7 as risk genes for gastric cancer on the genome and transcriptome level

    Get PDF
    Genetic associations between variants on chromosome 5p13 and 8q24 and gastric cancer (GC) have been previously reported in the Asian population. We aimed to replicate these findings and to characterize the associations at the genome and transcriptome level. We performed a fine-mapping association study in 1926 GC patients and 2012 controls of European descent using high dense SNP marker sets on both chromosomal regions. Next, we performed expression quantitative trait locus (eQTL) analyses using gastric transcriptome data from 143 individuals focusing on the GC associated variants. On chromosome 5p13 the strongest association was observed at rs6872282 (P = 2.53 × 10-04) and on chromosome 8q24 at rs2585176 (P = 1.09 × 10-09). On chromosome 5p13 we found cis-eQTL effects with an upregulation of PTGER4 expression in GC risk allele carrier (P = 9.27 × 10-11). On chromosome 8q24 we observed cis-eQTL effects with an upregulation of PSCA expression in GC risk allele carrier (P = 2.17 × 10-47). In addition, we found trans-eQTL effects for the same variants on 8q24 with a downregulation of MBOAT7 expression in GC risk allele carrier (P = 3.11 × 10-09). In summary, we confirmed and refined the previously reported GC associations at both chromosomal regions. Our data point to shared etiological factors between Asians and Europeans. Furthermore, our data imply an upregulated expression of PTGER4 and PSCA as well as a downregulated expression of MBOAT7 in gastric tissue as risk-conferring GC pathomechanisms

    Conceptualizations for cleaning OTEC heat exchangers

    No full text
    A critical operating aspect of Ocean Thermal Energy Conversion (OTEC) plants is the maintenance of clean surfaces on the seawater-side of the heat exchangers. The objective of this program was to assess the state of the art of biofouling control techniques and to evaluate the potential of these existing methods for solving the biofouling problems in the OTEC system. The first task of the program involved an in-depth review and discussion of various fouling control methods including water treatment, surface conditioning, and cleaning techniques. The methods considered applicable to OTEC were identified. This volume summarizes the second task of the program. The compatibility of the various cleaning and fouling control techniques with the different proposed heat exchanger designs and materials are discussed. Also provided are conceptual illustrations for adapting and incorporating the methods into an OTEC power plant. These conceptual designs suggest means for overcoming some of the shortcomings of the techniques which are considered suitable, however, detailed designs of the modified systems are beyond the scope of this report. Chlorination, chemical cleaning, Amertap recirculating sponge rubber balls, and MAN flow-driven brushes are the methods considered applicable for tubular heat exchangers with seawater inside the tubes. Water jets are suggested for the open-cycle and the ''trombone'' (Applied Physics Laboratory) heat exchanger designs. Although none of the methods are immediately applicable to OTEC in their present configuration, in several cases only minor developmental efforts should produce designs which can satisfy the stringent OTEC cleanliness requirements. Further research and development appear warranted for a number of other methods which indicate promise for long-range applicability. Specific recommendations are included
    corecore