397 research outputs found
Simulation and experimental evaluation of a flexible time triggered ethernet architecture applied in satellite nano/micro launchers
The success of small satellites has led to the study of new technologies for the realization of Nano and Micro Launch Vehicle (NMLV) in order to make competitive launch costs. The paper has the objective to define and experimentally investigate the performance of a communication system for NMLV interconnecting the End Systems as On-Board Computer (OBC), telemetry apparatus, Navigation Unit...we propose a low cost Ethernet-based solution able to provide the devices with high interconnection bandwidth. To guarantee hard delays to the Guide, Navigation and Control applications we propose some architectural changes of the traditional Ethernet network with the introduction of a layer implemented in the End Systems and allow for the lack of any contention on the network links. We show how the proposed solution has comparable performance to the one of TTEthernet standard that is a very expensive solution. An experimental test-bed equipped with Ethernet switches and Hercules boards by Texas Instruments is also provided to prove the feasibility of the proposed solution
Short-term use of dexamethasone/netilmicin fixed combination in controlling ocular inflammation after uncomplicated cataract surgery
Purpose: To evaluate the short-term anti-inflammatory effect of dexamethasone/netilmicin fixed combination in the management of ocular inflammation after cataract surgery. Patients and Methods: Open-label, randomized, active-controlled, clinical study con-ducted in 6 sites in Italy; 238 patients were randomized 2:1 to dexamethasone/netilmicin (dexa/net, n=158) or betamethasone/chloramphenicol (beta/chl, n=80). Treatment started the day of surgery and continued 4 times daily for 7 days. The primary efficacy parameter was the anterior chamber (AC) flare. The percentage of patients displaying none or mild (ie, only barely detectable) AC flare was defined as “efficacy rate”, whereas the percentage of patients showing a decrease of AC flare score from baseline was defined as “percentage of responders”. Additional parameters evaluated were AC cells, conjunctival hyperaemia, corneal and lid oedema, symptoms of ocular discomfort, visual acuity, and intraocular pressure. Dexa/net was considered effective if the efficacy rate was not inferior (by means of 97.5% confidence interval) to that of beta/chl. Results: After 7 days of treatment, no AC flare was observed in 92.8% (dexa/net) and 92.3% (beta/chl) of patients, whereas no AC cells were observed in 91.5% (dexa/net) and 93.6% (beta/chl) of patients, respectively. The “efficacy rate” was 100% in both groups, whereas the “percentage of responders” was 94.1% in the dexa/net and 93.6% in the beta/chl group. The p-value to reject the null hypothesis of inferiority was <0.001. Other efficacy parameters confirmed both treatments as highly effective, despite their difference in steroid content (2 mg/mL for beta/chl vs 1 mg/mL for dexa/net). IOP and visual acuity at the end of the study were comparable. Two cases of allergic conjunctivitis were considered adverse events and were both related to dexa/net. Conclusion: Short-term use of dexa/net fixed combination is safe and effective in the control of post-operative inflammation following uncomplicated cataract surgery
A parallel algorithm for the enumeration of benzenoid hydrocarbons
We present an improved parallel algorithm for the enumeration of fixed
benzenoids B_h containing h hexagonal cells. We can thus extend the enumeration
of B_h from the previous best h=35 up to h=50. Analysis of the associated
generating function confirms to a very high degree of certainty that and we estimate that the growth constant and the amplitude .Comment: 14 pages, 6 figure
Estrogen-receptor-positive breast cancer in postmenopausal women: The role of body composition and physical exercise
Breast cancer (BC) is the most commonly diagnosed cancer among women worldwide and the most common cause of cancer-related death. To date, it is still a challenge to estimate the magnitude of the clinical impact of physical activity (PA) on those parameters producing significative changes in future BC risk and disease progression. However, studies conducted in recent years highlight the role of PA not only as a protective factor for the development of ER+ breast cancer but, more generally, as a useful tool in the management of BC treatment as an adjuvant to traditional therapies. In this review, we focused our attention on data obtained from human studies analyzing, at each level of disease prevention (i.e., primary, secondary, tertiary and quaternary), the positive impact of PA/exercise in ER+ BC, a subtype representing approximately 70% of all BC diagnoses. Moreover, given the importance of estrogen receptors and body composition (i.e., adipose tissue) in this subtype of BC, an overview of their role will also be made throughout this review
Retromode imaging modality of epiretinal membranes
(1) Purpose: To determine the characteristics of macular epiretinal membranes (ERM) using non-invasive retromode imaging (RMI) and to compare retromode images with those acquired via fundus autofluorescence (FAF) and fundus photography. (2) Methods: Prospective observational case-series study including patients with macular ERM with no other ocular disease affecting their morphology and/or imaging quality. We compared RMI, FAF and fundus photography features by cropping and overlapping images to obtain topographic correspondence. (3) Results: In total, 21 eyes (21 patients) affected by ERM were included in this study. The mean area of retinal folds detected by RMI was significantly higher than that detected by FAF (11.85 ± 3.92 mm2 and 5.67 ± 2.15 mm2, respectively, p < 0.05) and similar to that revealed by fundus photography (11.85 ± 3.92 mm2 and 10.58 ± 3.45 mm2, respectively, p = 0.277). (4) Conclusions: RMI appears to be a useful tool in the evaluation of ERMs. It allows for an accurate visualization of the real extension of the retinal folds and provides a precise structural assessment of the macula before surgery. Clinicians should be aware of RMI's advantages and should be able to use them to warrant a wide range of information and, thus, a more personalized therapeutic approach
Pattern electroretinogram detects localized glaucoma defects
Purpose: We evaluated the clinical ability of pattern electroretinogram (PERG) to detect functional losses in the affected hemifield of open-angle glaucoma patients with localized perimetric defects. Methods: Hemifield (horizontally-defined) steady-state PERGs (h-PERGs) were recorded in response to 1.7 c/deg alternating gratings from 32 eyes of 29 glaucomatous patients with a perimetric, focal one-hemifield defect, 10 eyes of 10 glaucomatous patients with a diffuse perimetric defect, and 18 eyes of 18 age-matched normal subjects. Standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SD-OCT) for retinal nerve fiber layer (RNFL) thickness also were performed. h-PERG amplitudes and ratios, calculated corresponding hemifield perimetric deviations, as well as hemiretina RNFL thicknesses were analyzed. Results: h-PERG amplitudes, perimetric deviations, and RNFL thicknesses showed losses (P < 0.001) when comparing affected with unaffected hemifields of localized glaucomatous eyes. No differences were found in h-PERG amplitudes between hemifields of normal or diffuse glaucomatous eyes. h-PERG amplitude ratios (affected/ unaffected hemifield) in localized glaucoma were lower (P < 0.001) than the ratios from normal or diffuse glaucomatous eyes. The areas under the receiver operating characteristic curves for h-PERG amplitude ratios, comparing localized-defect glaucomatous eyes with normal or diffuse glaucomatous eyes, were 0.93 and 0.91, respectively. Conclusions: h-PERG assessment showed good diagnostic accuracy to confirm localized glaucomatous defects detected perimetrically. This test may be particularly useful in cognitively impaired patients or young/nonverbal patients unable to provide reliable visual fields. Translational Relevance: h-PERG provides a sensitive objective measure to confirm
- …