647 research outputs found
Intraoperative electrically auditory brainstem responses to monitor auditory functionality preservation during auditory brainstem implant application.
Background: Perceptual outcomes of individuals with neurofibromatosis type II implanted with auditory brainstem implant are poor, and many factors seem to be involved. Undoubtedly, the preservation of neural functionality is the crucial aspect. The aim of this study is to verify that the use of intraoperative electrically auditory brainstem responses can help to understand if there is neural damage related to the tumor, and / or surgery. Material and Methods: A retrospective case series analysis was performed to review data from 6 adult patients affected by neurofibromatosis type 2 who received an auditory brainstem implant. A correlation was sought between intraoperative electrophysiological data, auditory performance at 1 and 2.5 years of follow-up, and auditory brainstem implant stimulation levels. Results: Patients with a better perceptual outcomes were those with more intraoperative peaks and peaks with wider amplitudes in the electrically auditory brainstem response recordings. Conclusions: Electrically auditory brainstem responses used for auditory brainstem implant placement can be a valuable tool for monitoring the preservation of neural acoustic functionality
A Compact Solid State Detector for Small Angle Particle Tracking
MIDAS (MIcrostrip Detector Array System) is a compact silicon tracking
telescope for charged particles emitted at small angles in intermediate energy
photonuclear reactions. It was realized to increase the angular acceptance of
the DAPHNE detector and used in an experimental program to check the
Gerasimov-Drell-Hearn sum rule at the Mainz electron microtron, MAMI. MIDAS
provides a trigger for charged hadrons, p/pi identification and particle
tracking in the region 7 deg < theta < 16 deg. In this paper we present the
main characteristics of MIDAS and its measured performances.Comment: 13 pages (9 figures). Submitted to NIM
Movable wall and system with environmental condition optimisation functions
The present invention relates to the field of control of indoor environmental conditions. In particular, the invention relates to a movable wall with environmental condition optimisation functions, as well as a system comprising such movable wall, and an environmental condition optimisation method
WARP: a WIMP double phase Argon detector
The WARP programme for dark matter search with a double phase argon detector
is presented. In such a detector both excitation and ionization produced by an
impinging particle are evaluated by the contemporary measurement of primary
scintillation and secondary (proportional) light signal, this latter being
produced by extracting and accelerating ionization electrons in the gas phase.
The proposed technique, verified on a 2.3 liters prototype, could be used to
efficiently discriminate nuclear recoils, induced by WIMP's interactions, and
measure their energy spectrum. An overview of the 2.3 liters results and of the
proposed 100 liters detector is shown.Comment: Proceeding for IDM200
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
Cosmic ray detection based measurement systems: a preliminary study
Cosmic rays, mostly composed of high energy muons, continuously hit the Earth's surface (at sea level the rate is about 10 000 m−2 min−1). Various technologies are adopted for their detection and are widespread in the field of particle and nuclear physics. In this paper, cosmic ray muon detection techniques are assessed for measurement applications in engineering, where these methods could be suitable for several applications, with specific reference to situations where environmental conditions are weakly controlled and/or where the parts to be measured are hardly accessible. Since cosmic ray showering phenomena show statistical nature, the Monte Carlo technique has been adopted to numerically simulate a particular application, where a set of muon detectors are employed for alignment measurements on an industrial press. An analysis has been performed to estimate the expected measurement uncertainty and system resolution, which result to be strongly dependent on the dimensions and geometry of the set-up, on the presence of materials interposed between detectors and, ultimately, on the elapsed time available for the data taking
A new, very massive modular Liquid Argon Imaging Chamber to detect low energy off-axis neutrinos from the CNGS beam. (Project MODULAr)
The paper is considering an opportunity for the CERN/GranSasso (CNGS)
neutrino complex, concurrent time-wise with T2K and NOvA, to search for
theta_13 oscillations and CP violation. Compared with large water Cherenkov
(T2K) and fine grained scintillators (NOvA), the LAr-TPC offers a higher
detection efficiency and a lower backgrounds, since virtually all channels may
be unambiguously recognized. The present proposal, called MODULAr, describes a
20 kt fiducial volume LAr-TPC, following very closely the technology developed
for the ICARUS-T60o, and is focused on the following activities, for which we
seek an extended international collaboration:
(1) the neutrino beam from the CERN 400 GeV proton beam and an optimised horn
focussing, eventually with an increased intensity in the framework of the LHC
accelerator improvement program;
(2) A new experimental area LNGS-B, of at least 50000 m3 at 10 km off-axis
from the main Laboratory, eventually upgradable to larger sizes. A location is
under consideration at about 1.2 km equivalent water depth;
(3) A new LAr Imaging detector of at least 20 kt fiducial mass. Such an
increase in the volume over the current ICARUS T600 needs to be carefully
considered. It is concluded that a very large mass is best realised with a set
of many identical, independent units, each of 5 kt, "cloning" the technology of
the T600. Further phases may foresee extensions of MODULAr to meet future
physics goals.
The experiment might reasonably be operational in about 4/5 years, provided a
new hall is excavated in the vicinity of the Gran Sasso Laboratory and adequate
funding and participation are made available.Comment: Correspondig Author: C. Rubbia (E-mail: [email protected]), 33
pages, 11 figure
Discovery of underground argon with low level of radioactive 39Ar and possible applications to WIMP dark matter detectors
We report on the first measurement of 39Ar in argon from underground natural
gas reservoirs. The gas stored in the US National Helium Reserve was found to
contain a low level of 39Ar. The ratio of 39Ar to stable argon was found to be
<=4x10-17 (84% C.L.), less than 5% the value in atmospheric argon
(39Ar/Ar=8x10-16). The total quantity of argon currently stored in the National
Helium Reserve is estimated at 1000 tons. 39Ar represents one of the most
important backgrounds in argon detectors for WIMP dark matter searches. The
findings reported demonstrate the possibility of constructing large multi-ton
argon detectors with low radioactivity suitable for WIMP dark matter searches.Comment: 6 pages, 2 figures, 2 table
- …