29 research outputs found

    Quantification of ciprofloxacin in pharmaceutical products from various brands using FT-NIR: A comparative investigation of PLS and MCR-ALS.

    Full text link
    peer reviewedThis study aims to quantify ciprofloxacin in commercial tablets with varying excipient compositions using Fourier Transform Near-Infrared Spectroscopy (FT-NIR) and chemometric models: Partial Least Squares (PLS) and Multivariate Curve Resolution - Alternating Least Squares (MCR-ALS). Matrix variation, arising from differences in excipient compositions among the tablets, can impact quantification accuracy. We discuss this phenomenon, emphasizing potential issues introduced by varying certain excipients and its importance in reliable ciprofloxacin quantification. We evaluated the performance of PLS and MCR-ALS models independently on two sets of tablets, each containing the same drug substance but different excipients. The statistical results revealed promising results with PLS prediction error of 0.38% w/w of the first set and 0.47% w/w of the second set, while MCR-ALS achieved prediction errors of 0.67% w/w of the first set and 1.76% w/w of the second set. To address the challenge of matrix variation, we developed single models for PLS and MCR-ALS using a dataset combining both first and second sets. The PLS single model demonstrated a prediction error of 4.3% w/w and a relative error of 6.41% w/w, while the MCR-ALS single model showed a prediction error of 1.88% w/w and a relative error of 1.29% w/w. We then assessed the performance of the single PLS and MCR-ALS models developed based on the combination of the first and the second set in quantifying ciprofloxacin in various commercial tablet brands containing new excipients. The PLS model achieved a prediction error ranging between 6.2% w/w and 8.39% w/w, with relative errors varied between 8.53% w/w and 12.82% w/w. On the other hand, the MCR-ALS model had a prediction error between 1.11% w/w and 2.66% w/w, and the relative errors ranging from 0.8% to 1.74% w/w

    Contribution au développement d'électrodes polymériques sélectives aux ions :de l'élaboration à l'application à l'analyse organique et inorganique

    No full text
    Doctorat en sciences pharmaceutiquesinfo:eu-repo/semantics/nonPublishe

    New modified polymeric electrodes selective to local anaesthetic compounds

    No full text
    New polymeric electrodes responding to the cationic forms of tetracaine (TC), lidocaine (LD), and procaine (PC) were constructed by incorporating their ion-pair complexes (the salts of TC, LD and PC with phosphotungstic acid) into ethylene-vinyl acetate (E/VAC) copolymer. Other ion pairing agents investigated were silicotungstate and tetraphenylborate. The phosphotungstic acid resulted in the best linear and Nernstian response. A 1:1 (v/v) mixture of dioctyl phthalate (DOP) and nitrobenzene (NB) was used as plasticizer. The electrodes exhibited linear response over the concentration ranges 10-2-5.6 × 10-6, 10-2-2.5 × 10-2 and 10-2-1.8 × 10-5 M of TC, LD and PC, respectively. pH did not affect the electrode performances within the ranges 2.7-6.3, 2.6-6.7 and 2.8-7.5 for the three electrodes, respectively. Interferences are negligible for many organic base and alkali metal cations. Cations of similar structure interfere with LD and PC, but not appreciably with TC. Direct potentiometry was used to determine these compounds in pharmaceutical preparations with accurate results. © 1991.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore