3,679 research outputs found

    Assessing statistical significance of periodogram peaks

    Full text link
    The least-squares (or Lomb-Scargle) periodogram is a powerful tool which is used routinely in many branches of astronomy to search for periodicities in observational data. The problem of assessing statistical significance of candidate periodicities for different periodograms is considered. Based on results in extreme value theory, improved analytic estimations of false alarm probabilities are given. They include an upper limit to the false alarm probability (or a lower limit to the significance). These estimations are tested numerically in order to establish regions of their practical applicability.Comment: 7 pages, 6 figures, 1 table; To be published in MNRA

    Voltage variations identification using gabor transform and rule-based classification method

    Get PDF
    This paper presents a comparatively contemporary easy to use technique for the identification and classification of voltage variations. The technique was established based on the Gabor Transform and the rule-based classification method. The technique was tested by using mathematical model of Power Quality (PQ) disturbances based on the IEEE Std 519-2009. The PQ disturbances focused were the voltage variations, which included voltage sag, swell and interruption. A total of 80 signals were simulated from the mathematical model in MATLAB and used in this study. The signals were analyzed by using Gabor Transform and the signal pattern, time-frequency representation (TFR) and root-mean-square voltage graph were presented in this paper. The features of the analysis were extracted, and rules were implemented in rule-based classification to identify and classify the voltage variation accordingly. The results showed that this method is easy to be used and has good accuracy in classifying the voltage variation

    Microrheology of polyethylene oxide using diffusing wave spectroscopy and single scattering

    Get PDF
    Experiments investigating the local viscoelastic properties of a simple uncross-linked flexible polymer are performed on polyethylene oxide solutions in the semidilute regime using polystyrene beads of varying sizes and surface chemistry as probes. We measure the thermal motions of the beads to obtain the elastic and viscous moduli of our sample. Two different dynamic light scattering techniques, diffusing wave spectroscopy and quasielastic light scattering (QELS), are used to determine the dynamics of the probe particles. Diffusing wave spectroscopy probes the short time dynamics of the scatterers while QELS or single scattering measures the dynamics at larger times. This results in a larger frequency overlap of the data obtained from the microrheological techniques with the data obtained from the conventional bulk measurements. The moduli are estimated using a modified algebraic form of the generalized Stokes-Einstein equation. Comparison of microrheology with bulk measurements shows excellent similarity confirming the applicability of this method for simple, uncross-linked polymeric systems

    Reliability and Repeatability of Cone Density Measurements in Patients With Stargardt Disease and RPGR-Associated Retinopathy

    Get PDF
    PURPOSE: To assess reliability and repeatability of cone density measurements by using confocal and (nonconfocal) split-detector adaptive optics scanning light ophthalmoscopy (AOSLO) imaging. It will be determined whether cone density values are significantly different between modalities in Stargardt disease (STGD) and retinitis pigmentosa GTPase regulator (RPGR)–associated retinopathy. METHODS: Twelve patients with STGD (aged 9–52 years) and eight with RPGR-associated retinopathy (aged 11–31 years) were imaged using both confocal and split-detector AOSLO simultaneously. Four graders manually identified cone locations in each image that were used to calculate local densities. Each imaging modality was evaluated independently. The data set consisted of 1584 assessments of 99 STGD images (each image in two modalities and four graders who graded each image twice) and 928 RPGR assessments of 58 images (each image in two modalities and four graders who graded each image twice). RESULTS: For STGD assessments the reliability for confocal and split-detector AOSLO was 67.9% and 95.9%, respectively, and the repeatability was 71.2% and 97.3%, respectively. The differences in the measured cone density values between modalities were statistically significant for one grader. For RPGR assessments the reliability for confocal and split-detector AOSLO was 22.1% and 88.5%, respectively, and repeatability was 63.2% and 94.5%, respectively. The differences in cone density between modalities were statistically significant for all graders. CONCLUSIONS: Split-detector AOSLO greatly improved the reliability and repeatability of cone density measurements in both disorders and will be valuable for natural history studies and clinical trials using AOSLO. However, it appears that these indices may be disease dependent, implying the need for similar investigations in other conditions

    ‘Pseudopneumothorax’—Hold that chest tube!

    Get PDF
    We report a case of herniation of abdominal contents into the left hemithorax in a patient with a history of vague left-sided thoracoabdominal trauma 18 days previous to admission and who also had a recent 1-week history of upper respiratory symptoms, including cough, and then presented with dyspnoea and fever for 3 days. There was no preceding cardiorespiratory pathology of note. We also discuss the epidemiology, pathogenesis and management of blunt-traumatic diaphragmatic rupture

    Cellular Imaging Of The Tapetal-like Reflex In Carriers Of RPGR-associated Retinopathy

    Get PDF
    PURPOSE: To examine the features of the tapetal-like reflex (TLR) in female carriers of RPGR-associated retinopathy by means of adaptive optics scanning light ophthalmoscopy (AOSLO) and spectral domain optical coherence tomography. METHODS: Nine molecularly confirmed RPGR carriers and three healthy controls underwent ocular examination and the following retinal imaging modalities: color photography, near-infrared reflectance, fundus autofluorescence, spectral domain optical coherence tomography, and AOSLO. After identifying TLR areas across all imaging modalities, normalized local contrast of outer retinal bands on spectral domain optical coherence tomography was calculated and AOSLO-acquired photoreceptor mosaic analysis was performed. RESULTS: Seven carriers had TLR areas, which colocalized with increased rod photoreceptor reflectivity on confocal AOSLO and reduced cone photoreceptor densities. Parafoveal TLR areas also exhibited reduced local contrast (i.e., increased reflectivity) of the outer retinal bands on spectral domain optical coherence tomography (inner segment ellipsoid zone and outer segment interdigitation zone). Healthy controls did not show TLR. CONCLUSION: The cellular resolution provided by AOSLO affords the characterization of the photoreceptor mosaic in RPGR carriers with a TLR. Features revealed include reduced cone densities, increased cone inner segment diameters, and increased rod outer segment reflectivity

    Electrodeposited NiX2 (X= S, Se) thin films for solar cell applications

    Get PDF
    Thin films of nickel chalcogenide, NiX2 (X= S, Se) have been electrosynthesized on indiumtin-oxide (ITO) coated glass substrates. The films were characterized for their structural, morphological and compositional characteristics. Their optical and semiconducting parameters were also analysed in order to determine the suitability of the thin films for photoelectrochemical (PEC) / solar cell applications. Structural analysis via X-ray diffraction (XRD) analysis reveals that the films are polycrystalline in nature. Scanning electron microscope (SEM) studies reveals that the films were adherent to the substrate with uniform and pin-hole free. Compositional analysis via energy dispersive X-ray (EDX) technique confirms the presence of Ni, S, and Se elements in the films. The optical studies show that the films are of direct bandgap. Results on the semiconductor parameters analysis of the films showed that the nature of the Mott-Schottky plots indicates that the films obtained are of p-type material

    A Framework for Decision-Making within Strength & Conditioning Coaching

    Get PDF
    corecore