62 research outputs found
Surface chemistry of rare-earth oxide surfaces at ambient conditions: reactions with water and hydrocarbons
Rare-earth (RE) oxide surfaces are of significant importance for catalysis and were recently reported to possess intrinsic hydrophobicity. The surface chemistry of these oxides in the low temperature regime, however, remains to a large extent unexplored. The reactions occurring at RE surfaces at room temperature (RT) in real air environment, in particular, in presence of polycyclic aromatic hydrocarbons (PAHs), were not addressed until now. Discovering these reactions would shed light onto intermediate steps occurring in automotive exhaust catalysts before reaching the final high operational temperature and full conversion of organics. Here we first address physical properties of the RE oxide, nitride and fluoride surfaces modified by exposure to ambient air and then we report a room temperature reaction between PAH and RE oxide surfaces, exemplified by tetracene (C18H12) on a Gd2O3. Our study evidences a novel effect-oxidation of higher hydrocarbons at significantly lower temperatures (similar to 300 K) than previously reported (>500 K). The evolution of the surface chemical composition of RE compounds in ambient air is investigated and correlated with the surface wetting. Our surprising results reveal the complex behavior of RE surfaces and motivate follow-up studies of reactions between PAH and catalytic surfaces at the single molecule level
General model with experimental validation of electrical resonant frequency tuning of electromagnetic vibration energy harvesters
This paper presents a general model and its experimental validation for electrically tunable electromagnetic energy harvesters. Electrical tuning relies on the adjustment of the electrical load so that the maximum output power of the energy harvester occurs at a frequency which is different from the mechanical resonant frequency of the energy harvester. Theoretical analysis shows that for this approach to be feasible the electromagnetic vibration energy harvester’s coupling factor must be maximized so that its resonant frequency can be tuned with the minimum decrease of output power. Two different-sized electromagnetic energy harvesters were built and tested to validate the model. Experimentally, the micro-scale energy harvester has a coupling factor of 0.0035 and an untuned resonant frequency of 70.05 Hz. When excited at 30 mg, it was tuned by 0.23 Hz by changing its capacitive load from 0 to 4000 nF; its effective tuning range is 0.15 Hz for a capacitive load variation from 0 to 1500 nF. The macro-scale energy harvester has a coupling factor of 552.25 and an untuned resonant frequency of 95.1 Hz and 95.5 Hz when excited at 10 mg and 25 mg, respectively. When excited at 10 mg, it was tuned by 3.8 Hz by changing its capacitive load from 0 to 1400 nF; it has an effective tuning range of 3.5 Hz for a capacitive load variation from 0 to 1200 nF. When excited at 25 mg, its resonant frequency was tuned by 4.2 Hz by changing its capacitive load from 0 to 1400 nF; it has an effective tuning range of about 5 Hz. Experimental results were found to agree with the theoretical analysis to within 10%
Detecting imipenem resistance in Acinetobacter baumannii by automated systems (BD Phoenix, Microscan WalkAway, Vitek 2); high error rates with Microscan WalkAway
<p>Abstract</p> <p>Background</p> <p>Increasing reports of carbapenem resistant <it>Acinetobacter baumannii </it>infections are of serious concern. Reliable susceptibility testing results remains a critical issue for the clinical outcome. Automated systems are increasingly used for species identification and susceptibility testing. This study was organized to evaluate the accuracies of three widely used automated susceptibility testing methods for testing the imipenem susceptibilities of <it>A. baumannii </it>isolates, by comparing to the validated test methods.</p> <p>Methods</p> <p>Selected 112 clinical isolates of <it>A. baumanii </it>collected between January 2003 and May 2006 were tested to confirm imipenem susceptibility results. Strains were tested against imipenem by the reference broth microdilution (BMD), disk diffusion (DD), Etest, BD Phoenix, MicroScan WalkAway and Vitek 2 automated systems. Data were analysed by comparing the results from each test method to those produced by the reference BMD test.</p> <p>Results</p> <p>MicroScan performed true identification of all <it>A. baumannii </it>strains while Vitek 2 unidentified one strain, Phoenix unidentified two strains and misidentified two strains. Eighty seven of the strains (78%) were resistant to imipenem by BMD. Etest, Vitek 2 and BD Phoenix produced acceptable error rates when tested against imipenem. Etest showed the best performance with only two minor errors (1.8%). Vitek 2 produced eight minor errors(7.2%). BD Phoenix produced three major errors (2.8%). DD produced two very major errors (1.8%) (slightly higher (0.3%) than the acceptable limit) and three major errors (2.7%). MicroScan showed the worst performance in susceptibility testing with unacceptable error rates; 28 very major (25%) and 50 minor errors (44.6%).</p> <p>Conclusion</p> <p>Reporting errors for <it>A. baumannii </it>against imipenem do exist in susceptibility testing systems. We suggest clinical laboratories using MicroScan system for routine use should consider using a second, independent antimicrobial susceptibility testing method to validate imipenem susceptibility. Etest, whereever available, may be used as an easy method to confirm imipenem susceptibility.</p
A new laparoscopic technique for the placement of a permanent peritoneal dialysis catheter - The preperitoneal tunneling method
WOS: 000227332900014PubMed: 15529192Background: Mechanical outflow obstruction and leakage from the exit site of the catheter are two common complications of continuous ambulatory peritoneal dialysis. To lessen these complications and to achieve immediate use of the catheter, we developed a new laparoscopic technique for catheter placement. Methods: A total of 12 consecutive patients with end-stage renal failure were included in this study between April 2003 and July 2003. The average age of the patients was 42.4 years (range, 37-72). Patients were excluded only if a serious risk for general anesthesia was found. Using two 5-mm ports and a 3.3-mm mini-laparoscope, a peritoneal dialysis catheter was passed through a preperitoneal tunnel before the tip of the catheter was introduced into the pelvis. Routine peritoneal dialysis was started immediately after the operation while the patients were still in the operating room. Results: The mean operating time was 18.6 min (range, 12-37). There was no operative morbidity. The mean follow-up period was 4.3 months (range, 3-7). No leakage of the dialysate liquid or outflow obstruction was observed during this period. Conclusion: The advantages of this method include accurate placement, preperitoneal fixation, and immediate use of the catheter for routine peritoneal dialysis. We also believe that because of the preperitoneal fixation of the catheter, this technique will decrease outflow obstruction, which usually occurs due to omental wrapping or displacement of the catheter tip
A novel tunneling method for long-term peritoneal dialysis - Reply
WOS: 00023234340002
- …