2,458 research outputs found
Spot size measurements in the Eli-NP compton gamma source
A  high  brightness  electron  Linac  is  being  built  in  the  Compton  Gamma  Source  at  the  ELI  Nuclear  Physics  facility  in  Romania.  To  achieve  the  design  luminosity,  a  train of 32 bunches with a nominal charge of 250 pC and 16  ns  spacing  ,  will  collide  with  the  laser  beam  in  the  interaction  point.  Electron  beam  spot  size  is  measured  with  an  OTR  (optical  transition  radiation)  profile  moni-tors.  In  order  to  measure  the  beam  properties,  the  optical  radiation  detecting  system  must  have  the  necessary  accu-racy  and  resolution.  This  paper  deals  with  the  studies  of  different  optic  configurations  to  achieve  the  magnifica-tion,  resolution  and  accuracy  desired  considering  design  and  technological  constraints;  we  will  compare  several  configurations  of  the  optical  detection  line  to  justify  the  one chosen for the implementation in the Lina
Adubação fosfatada para palma de óleo.
Adubação Fosfatada para Palma de Óleo; Importância da adubação para a palma de óleo; O fósforo na cultura da palma de óleo; Importância da avaliação da fertilidade do solo para palma de óleo; Avaliação da disponibilidade de fósforo no solo; Fatores que afetam a disponibilidade de fósforo no solo e a eficiência da adubação fosfatada na palma de óleo; Acidez do solo; Fontes de fósforo; Doses de fósforo; Métodos de aplicação do fósforo para palma de óleo; Variação genotípica da palma de óleo quanto à eficiência de absorção de fósforo; Alternativas para manejo da adubação fosfatada para palma de óleobitstream/item/82996/1/Oriental-Doc388.pd
Optical issues for the diagnostic stations for the ELI-NP compton gamma source
A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches, 16 ns spaced, with a nominal charge of 250 pC will collide with the laser beam in the interaction point. Electron beam spot size is measured with optical transition radiation (OTR) profile monitors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accuracy and resolution. This paper deals with the studies of different optic configurations to achieve the magnification, resolution and accuracy in order to measure very small beam (below 30 μm) or to study the angular distribution of the OTR and therefore the energy of the beam. Several configurations of the optical detection line will be studied both with simulation tools (e.g. Zemax) and experimentally. The paper will deal also with the sensibility of optic system (in terms of depth of field, magnification and resolution) to systematic error
A novel marker of progression for atherosclerosis and cardiovascular diseases: serum gamma-glutamyltransferase enzyme activity.
Beam diagnostics for charge and position measurements in ELI-NP GBS
The advanced source of Gamma-ray photons to be built in Bucharest (Romania), as part of the ELI-NP European Research Infrastructure, will generate photons by Compton back-scattering in the collision between a multi-bunch electron beam and a high intensity recirculated laser pulse. An S-Band photoinjector and the following C-band Linac at a maximum energy of 720MeV, under construction by an European consortium (EurogammaS) led by INFN, will operate at 100Hz repetition rate with trains of 32 electron bunches, separated by 16ns and a 250pC nominal charge. The different BPMs and current transformers used to measure transverse beam position and charge along the LINAC are described. Design criteria, production status and bench test results of the charge and position pickups are reported in the paper, together with the related data acquisition systems
Adubação nitrogenada no milho no Oeste do estado do Pará.
O objetivo deste trabalho foi avaliar a resposta do milho (Zea mays) a doses de nitrogênio (N) e épocas de aplicação do fertilizante nitrogenado no oeste do Estado do Pará. O experimento de campo foi realizado em Latossolo Amarelo distrófico textura muito argilosa do Município de Belterra, Estado do Pará. O delineamento experimental foi o de blocos ao acaso com três repetições. Os tratamentos consistiram no arranjo fatorial 5 x 3, correspondendo a cinco doses de N (0, 30, 60, 90 e 120 kg ha?1; fonte: ureia) e três parcelamentos [(i) 100% no sulco de semeadura, (ii) 50% no sulco de semeadura e 50% em cobertura aos 35 dias da semeadura, (iii) 30% no sulco de semeadura e 70% em cobertura aos 35 dias da semeadura]. A produtividade de grãos de milho aumentou até a dose de 120 kg ha?1 de N e foi maior com o parcelamento da adubação nitrogenada do que com a aplicação total de N na semeadurabitstream/item/82197/1/Oriental-BDP84.pd
Cardiac biomarker testing in the clinical laboratory: Where do we stand? General overview of the methodology with special emphasis on natriuretic peptides
Diagnosis of heart failure (HF) is not based on a single test, but on a combination of history, physical examination and appropriate investigations. For these reasons, the accuracy of diagnosis by clinical means alone is often inadequate, especially in the early, asymptomatic stages of the HF. Thus, there is an increasing interest in the development of new cardiovascular biomarkers and, consequently, a great number of laboratory tests have recently been proposed for their assay. The aim of this article is to provide a general overview on the biomarkers, recommended by international guidelines, for the diagnosis, risk stratification, and follow-up of patients with HF. Cardiac natriuretic peptides and in particular the B-type related peptides, which are considered to be the first line biomarker for HF by international guidelines, will be discussed with special emphasis
Resposta do milho à adubação fosfatada em um latossolo amarelo do estado do Pará.
Objetivou-se avaliar a resposta do milho, cultivado na região do Oeste Paraense, à aplicação de doses, fontes e métodos de aplicação do fertilizante fosfatado no solo. O experimento foi desenvolvido no Município de Belterra, PA, em um Latossolo Amarelo distrófico de textura argilosa. O delineamento experimental utilizado foi o de blocos casualizados, com três repetições, em esquema fatorial 2 x 2 x 4, correspondendo a duas fontes de P [fosfato natural reativo de Arad (FNR) e superfosfato triplo (TSP)], duas formas de aplicação (a lanço em área total e incorporado ao solo e no sulco de semeadura) e quatro doses de P (0, 90, 180, 270 kg ha-1 de P2 O5). A cultura do milho respondeu em produtividade à adubação fosfatada, independente da fonte de P e do método de aplicação do fertilizante. Com relação à avaliação da produtividade de milho, o TSP reagiu de forma superior ao FNR. Quando aplicado no sulco de semeadura, a produtividade de milho foi superior com o TSP em comparação ao FNR. Em relação ao FNR, a produtividade foi superior quando essa fonte de P foi aplicada a lanço e incorporada, em relação à sua aplicação localizada no sulco de semeadur
- …
