458 research outputs found

    SHINe: Simulator for satellite on-board high-speed networks featuring SpaceFibre and SpaceWire protocols

    Get PDF
    The continuous innovation of satellite payloads is leading to an increasing demand of data-rate for on-board satellite networks. In particular, modern optical detectors generate and need to transfer data at more than 1 Gbps, a speed that cannot be satisfied with standardized technologies such as SpaceWire. To fill this gap, the European Space Agency (ESA) is supporting the development of a new high-speed link standard, SpaceFibre. SpaceFibre provides a data-rate higher than 6.25 Gbps, together with the possibility to use multiple Virtual Channels running over the same physical link, each one configurable with flexible Quality of Service parameters. These features make a SpaceFibre network very appealing but also complex to set up in order to achieve the desired end-to-end requirements. To help this process, a Simulator for HIgh-speed Network (SHINe) based on the open-source toolkit OMNeT++ has been developed and is presented in this paper. It supports the simulation of SpaceFibre and SpaceWire protocols in order to help both the final steps of the standardization process and the system engineers in the setup and test of new networks. SHINe allows to precisely simulate common network metrics, such as latency and bandwidth usage, and it can be connected to real hardware in a Hardware-in-the-Loop configuration

    Telemonitoring in the Covid-19 era: The tuscany region experience

    Get PDF
    Covid-19 has brought many difficulties in the management of infected and high-risk patients. Telemedicine platforms can really help in this situation, since they allow remotely monitoring Covid-19 patients, reducing the risk for the doctors, without decreasing the efficiency of the therapies and while alleviating patients’ mental issues. In this paper, we present the entire architecture and the experience of using the Tel.Te.Covid19 telemedicine platform. Projected for the treatment of chronic diseases, it has been technologically updated for the management of Covid-19 patients with the support of a group of doctors in the territory when the pandemic arrived, introducing new sensors and functionalities (e.g., the familiar use and video calls). In Tuscany (Central Italy), during the first wave of outbreak, a model for enrolling patients was created and tested. Because of the positive results, the latter has been then adopted in the second current wave. The Tel.Te.Covid19 platform has been used by 40 among general practitioners and doctors of continuity care and about 180 symptomatic patients since March 2020. Both patients and doctors have good opinion of the platform, and no hospitalisations or deaths occurred for the monitored patients, reducing also the impact on the National Healthcare System

    Role of interventional radiology in pudendal neuralgia: A description of techniques and review of the literature [Ruolo della radiologia interventistica nella nevralgia del nervo pudendo: Descrizione della tecnica e revisione della letteratura]

    Get PDF
    Purpose: The authors sought to evaluate indications, technical feasibility and clinical efficacy of computed tomography (CT)-guided pudendal nerve infiltration in patients with chronic anoperineal pain by reviewing the role of the CT technique in their personal experience and in the recent interventional literature. Materials and methods: Twenty-eight women, mean age 50 years, and with a diagnosis of pudendal neuralgia on the basis of clinical and electromyographic criteria were enrolled in the study. CT-guided pudendal nerve injections were performed during three consecutive sessions held 2 weeks apart. In each session, patients received two percutaneous injections: one in the ischial spine, and the other in the pudendal (Alcock's) canal. Results: One patient dropped out of the study after the first session. At clinical assessment, 24h h after treatment, 21/27 patients reported significant pain relief. At follow-up at 3, 6, 9 and 12 months, 24/27 patients reported a ≥ 20% improvement in the Quality of Life (QOL) index. Conclusions. In pudendal nerve entrapment, CT-guided perineural injection in the anatomical sites of nerve impingement is a safe and reproducible treatment with a clinical efficacy of 92% at 12 months. © 2009 Springer-Verlag Italia

    Multiparameter characterisation of vertebral osteoporosis with 3-T MR = Valutazione multiparametrica dell’osteoporosi vertebrale con RM a 3 Tesla

    Get PDF
    Purpose. This study was undertaken to evaluate the diagnostic capabilities of 3-Tesla (T) magnetic resonance (MR) in vertebral osteoporosis. Materials and methods. Thirty subjects (ten healthy controls, ten with osteoporosis but no fracture, ten with osteoporotic vertebral fractures) underwent MR of the lumbar spine. Turbo spin echo (TSE) T1-, T2- and T2- spectral selection attenuated inversion recovery (SPAIR) weighted imaging and spectroscopy for the selective evaluation of water and fat content were performed. The apparent diffusion coefficient (ADC) was calculated, and diffusion tensor imaging (DTI) was performed to create a map of the spatial arrangement of the tissue structures. Results. Morphological imaging detected recent vertebral fractures. In osteoporotic patients, spectroscopic imaging demonstrated an increase in the saturated fats and a decrease in the ADC, whereas the data provided by DTI demonstrated a bone structure with medium-degree anisotropy. Discussion. Osteoporosis is characterised by trabecular thinning, with an increase in the intertrabecular spaces, which are filled with fats. The anisotropic study and the subsequent assessment of colour and vector maps can provide a noninvasive tool for assessing the risk of fracture due to osteoporosis

    An easily integrable industrial system for gamma spectroscopic analysis and traceability of stones and building materials

    Get PDF
    In the building material and stones market, lots of restrictions are coming in different world zones. In Europe, a recent regulatory set up the maximum level of radiological emissions for materials intended for use in public and private building structures. For this reason, companies need to have a very efficient radiological measurements system in their production chain, in order to respect all the rules and to be competitive in the world market. This article describes CORSAIR, a Cloud-Oriented Measurement System for Radiological Investigation and Traceability of Stones. Our cyber-physical system consists of sensing nodes network connected to a data collection gateway through LoRaWAN protocol, and interfaces with a centralized cloud application. CORSAIR introduces a fast, repeatable, real-time and non-destructive method to measure radiological emissions and other parameters of each single building material item, uniquely identified by an applied RFID tag. The validity of this system is confirmed by in-situ measurement campaign compared with high-precision laboratory analysis. The results demonstrate the accuracy of the CORSAIR sensor and the possibility to easily integrate it in the company production chain without any change

    The Magnetic Spin Ladder (C_{5}H_{12}N)_{2}CuBr_{4}: High Field Magnetization and Scaling Near Quantum Criticality

    Full text link
    The magnetization, M(H≤30M(H \leq 30 T, 0.7 K ≤T≤300\leq T \leq 300 K), from single crystals and powder samples of (C5_{5}H12_{12}N)2_{2}CuBr4_{4} has been used to identify this system as an S=1/2S=1/2 Heisenberg two-leg ladder in the strong coupling limit, J⊥=13.3J_{\perp} = 13.3 K and J∥=3.8J_{\parallel} = 3.8 K, with Hc1=6.6H_{c1} = 6.6 T and Hc2=14.6H_{c2} = 14.6 T. An inflection point in M(H,T=0.7M(H, T = 0.7 K) at half-saturation, Ms/2M_{s}/2, is described by an effective \emph{XXZ} chain. The data exhibit universal scaling behavior in the vicinity of Hc1H_{c1} and Hc2H_{c2}, indicating the system is near a quantum critical point.Comment: 4 pages, 4 figure
    • …
    corecore