83 research outputs found

    Novacor left ventricular assist system versus heartmate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: A prospective study

    Get PDF
    AbstractObjective: Long-term mechanical circulatory support as a bridge-to-transplantation procedure and bridge to recovery is of increasing importance. The implantable left ventricular assist devices, Novacor N100 left ventricular assist system (Baxter Healthcare Corporation, Berkeley, Calif) and TCI HeartMate vented electric left ventricular assist system (Thermo Cardiosystems Inc, Woburn, Mass), have proved to be efficient devices in bridge-to-transplantation settings and for prolonged support. The two systems were compared with regard to reliability and morbidity. Methods: Between October 1996 and March 1998, a prospective, single-center study was done that included 40 patients, 20 of whom were treated with the Novacor system and 20 of whom were treated with the HeartMate device. The diseases were mainly dilated cardiomyopathy (13/9) and ischemic cardiomyopathy (6/10). There were no statistically significant differences between the two groups regarding age, sex, preoperative clinical blood chemistry values, hemodynamic data, or risk factors. Results: There were no statistically significant differences between the two groups with regard to postoperative hemodynamics, organ recovery, out-of-hospital support, and survival to heart transplantation. Mean duration of support was 235.3 ± 210 days for the Novacor group and 174.6 ± 175 days for the HeartMate group and mean out-of-hospital support was 241 ± 179 days and 166 ± 152 days for the two groups, respectively. Neurologic complications occurred significantly more often among the Novacor group, whereas the HeartMate group had a higher prevalence of infections and technical problems, which was statistically significant. Survival to transplantation was 65% for the Novacor group and 60% for the HeartMate group. Conclusions: Most patients had organ recovery with left ventricular assist system support, and a considerable number of patients in both groups underwent transplantation. However, both devices need revision to address the current problems, that is, thromboembolism for the Novacor device and infection and reliability for the HeartMate device. (J Thorac Cardiovasc Surg 2000;119:581-7

    Medico-legal autopsy in postoperative hemodynamic collapse following coronary artery bypass surgery

    Get PDF
    Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications to this serious condition is poorly known and their demonstration at autopsy is a challenging task. Isolated CABG was performed in 8,807 patients during 1988–1999. Of the patients, 76 (0.9%) developed sudden postoperative hemodynamic collapse resulting in subsequent emergency reopening of the median sternotomy and open cardiac massage. Further emergency reoperation could be performed in 62 (82%) whereas 14 patients died prior to reoperation and a further 21 did not survive the reoperation or died a few days later. All 35 (46%) patients who did not survive were subjected to medico-legal autopsy combined with postmortem cast angiography. By combining clinical data with autopsy and angiography data, various types of graft complications were observed in 27 (36%, 1.3 per patient) of the 76 patients with hemodynamic collapse. There were no significant differences in the frequency (33 vs. 40%) or number of complicated grafts per patient (1.2 vs. 1.4) between those who survived reoperation and who did not. Autopsy detected 25 major and minor findings not diagnosed clinically. Postmortem cast angiography visualized 2 graft twists not possible to detect by autopsy dissection only. Surgical graft complications were the most frequent single cause for sudden postoperative hemodynamic collapse in CABG patients leading to a fatal outcome in almost half of the cases. Postmortem angiography improved the accuracy of autopsy diagnostics of graft complications

    Extracorporeal life support in pediatric cardiac dysfunction

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Low cardiac output (LCO) after corrective surgery remains a serious complication in pediatric congenital heart diseases (CHD). In the case of refractory LCO, extra corporeal life support (ECLS) extra corporeal membrane oxygenation (ECMO) or ventricle assist devices (VAD) is the final therapeutic option. In the present study we have reviewed the outcomes of pediatric patients after corrective surgery necessitating ECLS and compared outcomes with pediatric patients necessitating ECLS because of dilatated cardiomyopathy (DCM).</p> <p>Methods</p> <p>A retrospective single-centre cohort study was evaluated in pediatric patients, between 1991 and 2008, that required ECLS. A total of 48 patients received ECLS, of which 23 were male and 25 female. The indications for ECLS included CHD in 32 patients and DCM in 16 patients.</p> <p>Results</p> <p>The mean age was 1.2 ± 3.9 years for CHD patients and 10.4 ± 5.8 years for DCM patients. Twenty-six patients received ECMO and 22 patients received VAD. A total of 15 patients out of 48 survived, 8 were discharged after myocardial recovery and 7 were discharged after successful heart transplantation. The overall mortality in patients with extracorporeal life support was 68%.</p> <p>Conclusion</p> <p>Although the use of ECLS shows a significantly high mortality rate it remains the ultimate chance for children. For better results, ECLS should be initiated in the operating room or shortly thereafter. Bridge to heart transplantation should be considered if there is no improvement in cardiac function to avoid irreversible multiorgan failure (MFO).</p
    corecore