36 research outputs found
Develpoment of High-Speed Active Vibration Control System Based on TMS32C6713 Microprocessor and Study the Simulink
In this thesis, we have developed a high-speed active control system
based on the TMS320C6713 microprocessor to control the vibration of the
structure actively. This system is composed of the DSP microprocessor,
Piezoelectric(PZT) driver, PZT actuator and sensors.
In particular, PZT actuator can generate ±200 ~ ± 450 variable voltage
using the H-bridge circuit and DC-DC converter. In addition, we made a
control box which is composed of PCBs for several circuits and A/D, D/A
devices with the same speed resolution of the main processor. The
designed control box is portable and practical. Also TMS320C6713
microprocessor is conveniently to simulate the vibration system's input
IV
and output signals using the Matlab. The simulation is based on the PPF
control algorithm to reduce vibration. Through the extensive experiments,
the real-time control performance of the system has been verified. The
comparisons are also presented between the experiments and simulation
results.Abstract
그림목차
표 목차
제 1 장 서 론 1
1.1 연구 배경 1
제 2 장 Active Control System의 개요 6
2.1 System의 개요 및 구성 6
2.2 System의 개발 환경 10
제 3 장 System의 수학적 모델링 17
3.1 압전 기본식과 변위에 대한 모델링 17
제 4 장 External Device의 개발 22
4.1 A/D Interface 22
4.2 D/A Interface 25
제 5 장 Actuator Driver의 개발 27
5.1 PZT Actuator Amp Driver 27
5.2 고전압 전원 공급장치 30
5.3 Control Cell의 구성 35
5.4 휴대 가능한 제어 시스템 37
5.5 전원부의 분리 40
5.6 시뮬 링크(Simulink)의 적용 43
제 6 장 System의 성능실험 44
6.1 PPF 제어 알고리즘 44
6.2 테스트 환경 46
6.3 PZT의 Signal Sensing 48
6.4 Actuator Driver의 성능 테스트 49
6.5 능동제어 실험 52
6.6 PZT 센서 위치 시뮬레이션 54
제 7 장 결 론 57
참고 문헌 5
Development of a Measurement Device for Modeling Battery Volume Expansion
학위논문(석사) -- 서울대학교 대학원 : 공과대학 재료공학부, 2024. 2. 최인석.고출력, 고용량, 장수명을 특징으로 하는 배터리에 대한 연구가 활발히 진행되고 있는 가운데, 다양한 조건에서의 배터리 안정성 및 신뢰성 문제는 여전히 중요한 이슈로 남아있다. 이러한 문제와 연관하여 본 연구에서는 다양한 압력 조건하에서 충방전시 파우치형 배터리 셀의 부피 변화를 측정할 수 있는 장치를 개발하였다.특히 가압볼트와 스프링으로 구성된 직관적이면서도 복잡하지 않은 가압 방식을 통해 충방전 중 배터리에 가해지는 압력을 모사할 수 있도록 설계되었으며, 쉽게 구할 수 있는 일반 로드 셀과 디지털 변위 측정기를 사용하여 정밀한 하중 측정 및 배터리 변위 변화 측정 데이터를 얻을 수 있도록 하였다. 개발된 장치의 하중 및 변위 데이터의 신뢰성은 기존 인장 실험 장치인 Instron 5582를 이용하여 기준시편에 대한 압축 실험을 통해 탄성 계수를 비교하여 검증하였으며, 최종적으로 실제 파우치 셀 실험을 통해서 서로 다른 압력 조건하에서 파우치 셀 충방전 시의 변위의 변화를 측정할 수 있는지를 확인하였다. 본 연구에서 개발된 장치는 배터리의 안정성을 평가하는 데 필요한 모델링을 위한 중요한 데이터를 제공하는 도구로 활용될 것이며, 향후 배터리 성능 개선 및 안전성 확보에 기여할 것으로 기대된다.In the realm of advanced research aimed at batteries featuring high power, high capacity, and longevity, the issue of assessing battery stability and reliability under diverse conditions persists as a pivotal concern. This investigation introduces a novel apparatus capable of precisely gauging the volumetric expansion of pouch-type battery cells during pressurized charge-discharge cycles across a spectrum of pressure settings. The apparatus is ingeniously designed, utilizing a straightforward mechanism comprising pressure bolts and springs to accurately emulate the pressure impacts on batteries during operational cycles. It leverages standard load cells for meticulous load measurement and digital displacement meters to acquire detailed data on the battery volume expansion. The veracity of the load and displacement information procured through this apparatus was corroborated by conducting compression tests on reference specimens with the established tensile testing equipment, Instron 5582, thereby comparing the elastic modulus. The efficacy of the developed device was further validated via empirical pouch cell experiments, which demonstrated its competency in tracking the volumetric changes of battery cells under varied pressurized conditions during charge and discharge. Envisioned to be a critical tool for generating key data essential for modeling battery stability, this device is poised to significantly advance battery performance optimization and safety enhancement efforts.초록 i
목차 ii
표 목차 iv
그림 목차 iv
1. 서론 1
1.1. 연구 배경 1
1.2. 연구 목적 9
2. 장치 설계 및 제작 11
2.1. 장치 개념화 13
2.2. 파트별 설계 구체화 16
2.3. 상세 도면 설계 및 장치 제작 22
3. 장치 검증 28
3.1. 힘의 전달 검증 29
3.2. 변위 검증 32
3.2.1. Instron5582 압축 시험 32
3.2.2. 장치 압축 시험 42
3.2.3. 제작된 장치의 초기점 설정 48
3.3. 배터리에 대한 장치 검증 50
3.3.1. 가압 상태에서의 충방전 테스트 50
3.3.2. 가압 상태에서의 팽창 분석 54
4. 결론 및 향후 연구 55
4.1. 결론 및 요약 55
4.2. 향후 연구 56
참고문헌 57
Abstract 62석
A New technology for improvement of the step coverage in CVD process for ULSI metallization : PACVD (Plasma assisted chemical vapor deposition)
학위논문(박사)--서울대학교 대학원 :금속공학과,1999.Docto
화학증착법에 의한 초고집적 소자 배선용 알루미늄 박막 형성에 있어서 플라즈마 효과
학위논문(석사)--서울대학교 대학원 :금속공학과 재료공학전공,1996.Maste
ALK와 mTOR 억제제인 alectinib와 everolimus 복합요법의 미분화 대세포 림프종 세포에 대한 증식억제 상승효과 분석
학위논문 (석사)-- 서울대학교 대학원 : 의과대학 협동과정 종양생물학전공, 2018. 8. 윤성수.The purpose of this study was to investigate the synergistic effect of combination treatment of two drugs on ALK-positive cancer cells. The combination treat resulted in synergistic effect in Karpas299 cells but not in SU-DHL-1 cells. Viability of Karpas299 cell was decreased to 26.4% (p<0.001) by combination treatment of alectinib and everolimus compared with the single drug treated groups (alectinib: 59.5%, everolimus: 51.6%), and the value of Combination Index (CI) indicating synergism was 0.316. Moreover, combination treatment in Karpas299 augmented ALK-mTOR de-phosphorylation, and cleavage of poly ADP ribose polymerase (PARP) molecules. Combination treatment significantly increased the numbers of Karpas299 cells arrested at subG1 (everolimus: p= 0.0096), and G0/G1 (alectinib: p= 0.0018everolimus: 0.0013). We further investigated the biological differences between Karpas299 and SU-DHL-1, the expression pattern of ALK isoforms (ALK-201 and 203) was different between the two cell lines. Overall, Combination treatment with alectinib and everolimus synergistically reduced cell survival, augmented inhibition of mTOR signaling, and increased cell cycle arrest in Karpas299 but not in SU-DHL1 cells. This set of results can suggest that the possibility of a novel combination treatment for ALK-positive lymphoma patients. It also provides an approach to developing new therapies.Contents
Abstract…………………………………………………04
Contents…………………………………………………06
Introduction……………………………………………07
Material and methods………………………………10
Results……………………………………………………17
Discussion………………………………………………26
Figure legend…………………………………………29
Figures and table……………………………………32
References……………………………………………39
List of tables and figures…………………………44
List of Abbreviations………………………………46
Abstract in Korean………………………………….47Maste
Method and Apparatus for Processing MRI Images
자기공명 영상 생성방법 및 그를 위한 장치를 개시한다.대상체의 복수의 슬라이스에게 공간 부호화 경사자장 및 방사형 샘플링을 적용하기 위한 보정 경사자장을 인가하고, 방사형 샘플링된 자기공명 신호를 수신하여 멀티 밴드 상에서 방사형 샘플링이 적용된 자기공명 영상 생성방법 및 그를 위한 장치에 관한 것이다
