32 research outputs found

    Modern Systems Supporting the Work of the Engineer

    No full text
    W artykule przedstawiono zagadnienia dotyczące technologicznych baz danych. Omówiono budowę i zastosowanie systemów CAD/CAM.The article presents issues related to technology databases. The construction and use of CAD/CAM systems

    Przegląd rozwiązań zastosowanych w urządzeniach rehabilitacyjnych wykorzystujących muskuły i siłowniki pneumatyczne

    No full text
    The article presents selected rehabilitation devices with the use of classic actuators and pneumatic muscles. Manipulators supporting the movements of the lower and upper limbs of humans are presented. Moreover, the construction of actuators and pneumatic muscles is described.W artykule przedstawiono wybrane urządzenia rehabilitacyjne z zastosowaniem klasycznych siłowników oraz muskułów pneumatycznych. Zaprezentowano manipulatory wspomagające ruchy kończyn dolnych i górnych człowieka. Ponadto opisano budowę siłowników i muskułów pneumatycznych

    Biomedical KL-720 measurement system and thermovision in students educating of engineering studies

    No full text
    W artykule omówiono zagadnienia dotyczące badań termowizyjnych oraz badań biomedycznych z wykorzystaniem zestawu edukacyjnego KL-720. Wykorzystano moduł fotopletyzmograficzny do oceny krążenia w naczyniach włosowatych opuszków palców oraz badano temperaturę mięśnia dwugłowego ramienia podczas wysiłku fizycznego.In the article issues concerning of thermovision research and the biomedical research with the educational KL 720. A fotopletyzmografic module was exploited for the evaluation of circulating in capillaries of fingers and a temperature of the biceps was being checked during a physical effort

    Pneumatic control system in manufacturing processes

    No full text
    Przedsiębiorstwa produkcyjne dążą do zautomatyzowania procesów produkcyjnych. Następuje to w wyniku zastosowania automatów, robotów oraz manipulatorów. Podstawową przesłanką do wprowadzania tego typu rozwiązań jest ciągły wzrost kosztów pracy ludzkiej. Wszelkiego rodzaju automaty przemysłowe, zastępują pracę fizyczną człowieka, skracają także czas produkcji wyrobów. W przemyśle, częstym rozwiązaniem jest stosowanie automatów oraz manipulatorów pneumatycznych, ze względu na niewielki koszt ich eksploatacji, powszechną dostępność: źródła energii, którym jest sprężone powietrze. W artykule przedstawiono elementy pneumatyczne układów sterowania: pneumatyczne elementy wykonawcze, elementy sterujące przepływem i ciśnieniem powietrza. Zaprezentowano zastosowanie pneumatycznych układów sterowania w przemyśle.Production companies strive to automate of production processes. This is due to the use of automatic devices, robots and manipulators. The basic premise for implementing such solution is continuous increase of human labour costs. All kinds of industrial automatic machines replace physical human work and cut down the production time. In industry, a common solution is the use of pneumatic automatic machines and manipulators, due to their low cost of operation and widespread availability of the source of energy which is compressed air. In this paper pneumatic elements of control systems, pneumatic actuators, elements controlling the flow and pressure of air were presented. The exemplary of application of pneumatic control system in industry were presented too

    Example of using computer engineering programs for systems of the pneumatics in students education

    No full text
    W artykule podano sposób przeprowadzenia doboru podstawowych parametrów elementów napędowych i sterujących. Ich charakterystyki zobrazowano, podając wyniki komputerowej symulacji działania podstawowego układu napędowego.In the article the manner of conducting the selection parameters of the controls and drive components. Their characteristics were illustrated the results of the computer simulation of the primary drive system

    It systems supported production

    No full text
    W procesach planowania produkcji i sterowania ich przebiegiem coraz częściej wykorzystuje się informatyczne systemy ERP/ERPII. Stanowią one główne źródło informacji i wspierają firmy w podejmowaniu decyzji. Są wsparciem informacyjnym, organizacyjnym i finansowym dla przedsiębiorstw, zastępując niekiedy pracę człowieka w wielu obszarach planowania i kierowania produkcją.Production planning and control processes are increasingly using ERP/ERP II IT systems. They are main source of information and support companies in making decisions. They provide information, organizational and financial support for companies, sometimes replacing human work in many areas of production planning and management

    Technical Solutions Enabling the Physical Training of Astronauts During Long-Term Stays at Space Stations

    No full text
    This article describes problems related to the adaptation of the human body to the state of weightlessness. International studies on changes in the parameters of the musculoskeletal and cardiovascular systems are analysed. The paper also presents technical solutions in the form of numerous devices enabling human functioning in microgravity conditions, without significant decrease in physical capacity, as well as muscle and bone atrophy. The chief purpose of this paper is to propose an innovative piece of equipment that applies two pneumatic actuators for training of lower bodily parts of astronauts in a space station. The equipment recommended in the article is of the authors’ own patent. Additionally, the authors put forward a proposition of how to control the patented device in a novel way

    Sampling Interval Selection for 3D Surface Roughness Measurements Using the Contact Method

    No full text
    The article presents the impact of sampling interval ΔX=ΔY upon the precision of parametrical assessment of roughness of selected surfaces. Moreover this study introduces theoretical analysis of sampling interval selection based on analysis of the probability of covering an unordered set of extreme points of surface with an ordered set of measurement points. As the result, the final formula was formulated, which enables to calculate the maximum sampling rate ΔX=ΔY. This guarantees a full 100% coverage of the vertices examined by the unevenness of the measuring grid

    Badania beztłoczyskowego siłownika pneumatycznego z przeniesieniem magnetycznym

    No full text
    The article presents the results of experimental and numerical tests of a rodless actuator with magnetic transfer. The study concerns the dynamic operation of the actuator. A series of measurements of pressure variability as a function of the distance and speed of the actuator’s operation on a real stand were performed. The study was repeated by modeling the system in the FluidSim environment. The obtained variation waveforms were compared with the real ones in order to determine the suitability of this type of tool for testing actuators.W artykule przedstawiono wyniki badań eksperymentalnych i numerycznych siłownika beztłoczyskowego z przeniesieniem magnetycznym. Badanie dotyczy pracy dynamicznej siłownika. Wykonano szereg pomiarów zmienności ciśnień w funkii drogi i prędkości działania siłownika na stanowisku rzeczywistym. Powtórzono badanie modelując układ w środowisku FluidSim. Uzyskane przebiegi zmienności porównano z rzeczywistymi, w celu określenia przydatności tego typu narzędzia do badań siłowników

    An Original System for Controlling the Speed of Movement of Pneumatic Drives in Rehabilitation Devices

    No full text
    The aim of the article is to present an original method of speed control and simultaneous stroke of the piston rods of two pneumatic cylinders using potentiometric position transducers, pneumatic solenoid valves, properly scaled throttle-check valves, solenoid valves and a microcontroller with power modules for solenoid valves. Initial experimental studies of the control system for simultaneous displacement of two piston rods of pneumatic actuators were carried out. The purpose of the research was to obtain the characteristics of the displacement of the extension of two pneumatic drives. The obtained results were analyzed. The results of the measurements confirmed the possibility of applying the presented control to rehabilitation devices for passive exercises of the lower extremities. The advantage of the proposed control system is its reaction speed, which is a response to changes in operating conditions of a given actuator, such as: external disturbances, own resistance of the controlled device, frictional resistance or movement caused by the patient exercising on the rehabilitation device moved by these actuators