10 research outputs found

    Toxicity of perfluorinated carboxylic acids for aquatic organisms

    Get PDF
    Toxicity of perfluorinated carboxylic acids with carbon chain C8 to C12 were tested with oligochaeta Tubifex tubifex. Toxicity was evaluated as the exposure time ET50 from onset of damage of the oligochaeta in saturated aqueous solutions. The ET50 fluctuated between 25 and 257 minutes. No statistically significant difference was found among the C8, C9 and C12 acids (ET50 between 143 and 257 minutes with large standard deviation). The acids with carbon chain C10 and C11 induced the effect significantly quicker (25 to 47 minutes). No acute toxicity measured in the three-minute test was observed in any case

    Interlaboratory study of ethanol usage as an internal standard in direct determination of volatile compounds in alcoholic products

    No full text
    A collaborative interlaboratory study on the method of direct quantitation of volatile compounds in spirit drinks and alcoholic products was conducted. The discussed method applies ethanol, the major volatile component of an alcoholic product, as an internal standard. In this study 9 laboratories from 4 different countries were supplied with standard solutions for gas chromatographic measurements. Five aqueous ethanol 40% (v/v) standard solutions containing target compounds in concentrations ranging from 10 mg/L to 400 mg/L of absolute alcohol were prepared and sent to the participants for quantification of acetaldehyde, methyl acetate, ethyl acetate, methanol, 2-propanol, 1-propanol, 2-methyl-1-propanol, 1-butanol and 3-methyl-1-butanol. The interlaboratory study was evaluated according to the ISO 5725 standards and the Eurachem guide. The within-laboratory precision varied between 0.4% and 7.5% for all samples and compounds, showing a sufficiently high repeatability of the method. The between-laboratory precision was found to vary within a satisfactory range of 0.5% ÷ 10.0%. Precision of the method was well within the range predicted by the Horwitz equation for all analytes. The analysis of trueness showed that the bias of the method is insignificant at the significance level α = 5%. The determined concentrations of the analytes compared well to the gravimetrical values thus showing very satisfactory accuracy of the method. The results of the interlaboratory study confirmed that “Ethanol as Internal Standard” method is robust and reliable and can be used as a standard reference method for analysing volatile compounds in water-ethanol samples. The possibilities of method validation according to the previously obtained experimental data were shown

    Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments

    No full text
    corecore