7 research outputs found

    Effect of Stirrup Spacing and Polypropylene Fiber Ratio on Behavior of Reinforced Concrete Beams

    Get PDF
    In this study, the effect of the change of stirrup ratio and polypropylene (PP) fiber ratio on the behavior of reinforced concrete beams was investigated. The variables of this study consisting of without stirrup, spacing up to 20 %, 40 % and 80 % of beam depth as stirrup spacing and 0.125 % and 0.500 % of the weight of reinforced concrete beam were used as PP fiber ratios. In the context of experimental study, 1/2 scaled 12 reinforced concrete beams were tested with 4-point bending mechanism. In the light of the obtained data, the load-displacement, stiffness and energy absorption graphs were plotted. The results were interpreted comparatively. According to the results, it is observed that the PP fiber additive significantly changed the behavior of the reinforced concrete beams, and the fiber effect decreased in proportion to the increase of the stirrup rate. It has been observed that the cracks spread more to the beam surfaces with the increase of PP fibers. In addition, the increase in the fiber ratio especially in the non-stirrup beams increases the bending capacity

    INVESTIGATION OF SHEAR BEHAVIOR OF REINFORCED CONCRETE BEAMS UNDER SIMPLE AND FIXED SUPPORT CONDITIONS

    Get PDF
    Many experimental studies were carried out to research about reinforced concrete beams, which are an important part of the structural bearing system. In these studies, simple support conditions were generally taken into consideration. However, it is known that the support zones of beams in reinforced concrete buildings are closer to the fixed support conditions. In this study, the effect of the change of support conditions in reinforced concrete beams on the beam shear behavior was examined. For this purpose, 4 full-scale reinforced concrete beam elements were tested on a 4 point loading mechanism. Two of these specimens were tested with simple support and two with fixed support. In order to determine the behavior of the test elements, load-displacement curves were drawn, stiffness and energy consumption capacities were determined and cracks formed during the test were examined. When the test results were examined, it was found that the behavior of the fixed supported specimens were quite different from the ones of the simple supported specimens

    TBDY 2018’e GÖRE TARİHİ SİLLE AK CAMİNİN STATİK ANALİZİ

    Get PDF
    TBDY 2018’e GÖRE TARİHİ SİLLE AK CAMİNİN STATİK ANALİZİÖzetKültürün önemli bir parçası olan tarihi binaların deprem gibi doğal afetler ve insanoğlunun yıpratıcı etkilerine karşı korumak ve gelecek nesillere aktarmak çok önemlidir. Bu tür yapıları korumak için tarihi binaların yapısal davranışlarını iyi bilmek gerekir. Tarihi yapıların depreme karşı güvenli olup olmadığını anlamak için yapıların deprem performans analizi yapılmalıdır. Günümüzde sonlu elemanlar yöntemi, tarihi binaların karmaşık geometri sistemlerinin modellenmesinde ve yapısal analizinde yaygın olarak kullanılmaktadır. Çalışmaya örnek teşkil edecek tarihi yapı; Türk İslam Sanatı açısından önemli bir yere sahip olan Konya’daki Sille Ak Cami’dir. 1864 yılında inşa edilip 400 metrekarelik alanı ile Sille’nin en büyük camisidir. Tarihi Sille Ak Caminin TBDY 2018’e göre mevcut durumunun statik hesabı yapılmış ardından SAP 2000 programında yapısal analizi yapılmıştır. Bu çalışmada, yapının taşıyıcı sistemin durumu, kullanılan malzemelerin özellikleri, meydana gelen hasarların değerlendirilmesi, mevcut durumunun tespiti yapılarak gelecek nesillere taşınması, gerekli parametrelerin tartışılarak çözüm önerilerinin ortaya konması amaçlanmaktadır.Anahtar Kelimeler: Tarihi Yığma Yapı, TBDY-2018’e Göre Analizi, Sille Ak CamiiSTATIC ANALYSIS OF HISTORICAL SİLLE AK MOSQUE ACCORDING TO TBDY-2018AbstractIt is very important to protect the historical buildings, which are an important part of the culture, against natural disasters such as earthquakes and the destructive effects of human beings and to pass them on to future generations. To protect such structures, it is necessary to know the structural behavior of historical buildings. Earthquake performance analysis of the structures should be performed to see whether the historical buildings are safe from earthquakes. Today, the finite element method is widely used in the modeling and structural analysis of complex geometry systems of historical buildings. The historical structure that will serve as an example for the study; Sille Ak Mosque in Konya, which has an important place in Turkish Islamic Art. Built in 1864, it is the largest mosque in Sille with an area of 400 square meters. According to TBDY 2018, the structural analysis of SAP 2000 program was performed by manual static calculation according to the current situation of the historical Sille Ak Mosque. In this study, it is aimed that evaluate the condition of the structural system, the properties of the materials used, the evaluation of the damages occurring, the determination of the current state of the structure to transfer the next generations, and the solution of the necessary parameters by discussingKeywords: Historical Masonry Building, Analysis According to TBDY-2018, Sille Ak Mosqu

    TARİHİ SİLLE SUBAŞI HAMAMI TAŞIYICI SİSTEM ANALİZİ

    Get PDF
    TARİHİ SİLLE SUBAŞI HAMAMI TAŞIYICI SİSTEM ANALİZİÖzetBu çalışmada, 19. yüzyıl Osmanlı Dönemi’nde inşa edilen ve Konya İli Selçuklu İlçesi’ne bağlı Sille Ak Mahallesi’nde bulunan tarihi Subaşı Hamamı’nın mevcut durum değerlendirmesi yapılıp, yapının statik ve dinamik yükler altındaki durumu incelenmiştir. Yapının üç boyutlu modeli oluşturulmuş, sonlu elemanlar yöntemine göre lineer analizi yapılmış ve taşıyıcı elemanları üzerinde oluşan gerilmeler ile yerdeğiştirmeler incelenmiştir. Subaşı Hamamı mimari açıdan kesit ve iç tasvir olarak iki sıcaklık, iki ılıklık ve bir su deposundan oluşmaktadır. İki sıcaklık ve iki ılıklık mekanının üzeri tuğladan yapılmış kubbeden, su deposunun üzeri ise beşik tonoz ile örtülmüştür. 19.5x18 metre boyutuna sahip olan hamamın yapılan araştırma, inceleme ve analiz sonucunda, yapının mevcut kesitlerinin büyük olmasından dolayı basınç ve kesme gerilmelerine karşı yeterli dayanımının olduğu; kubbe, beşik tonoz ve kapı köşelerinde bazı çatlakların oluştuğu; modal analiz sonunda mod şekilleri incelendiğinde en fazla zorlanan kısmın beşik tonoz olduğu tespit edilmiştir.Anahtar Kelimeler: Tarihi Yapı, Yığma Yapı, Taşıyıcı Sistem Analizi, Statik Lineer AnalizSTRUCTURAL ANALYSIS OF HISTORICAL SILLE SUBASI BATH AbstractIn this study, the present situation of the historical Subasi Bath, which was built in the 19th century Ottoman Period and located in the Sille Ak District of the Selcuklu District of Konya Province, was evaluated and the status of the building under static and dynamic loads was examined. A three-dimensional model of the structure was created using a computer program, a linear analysis was made according to the finite element method, and the stresses and displacements on the carrier elements were examined. Subasi Bath consists of two the hottest rooms, two the tepidity rooms and one water reservoir in terms of architectural cross-section and internal depiction. The hottest and the tepidity rooms spaces are covered with a dome made of brick, while the water tank is covered with a cradle vault. As a result of the research, examination and analysis of the bath, which has a size of 19.5x18 meters, it has sufficient resistance against pressure and shear stresses due to the big cross sections of the building; there are some cracks in the dome, cradle vault and door corners; When the modal analysis was examined, the most critical part was found to be the cradle vault.Keywords: Historical Structure, Masonry Structure, Structural Analysis, Static Analysi

    PENCERE BOŞLUKLU PERDE DUVARLA GÜÇLENDİRİLMİŞ 1/3 ÖLÇEKLİ BETONARME ÇERÇEVELERİN DAVRANIŞI

    Get PDF
    Bu deneysel çalışmada, 1/3 ölçekli, tek açıklıklı, iki katlı, 6 adet betonarme çerçeve üretilmiş ve pencere boşluklu veya boşluksuz dolgu duvar ile güçlendirilerek davranışları araştırılmıştır. Bu deney numuneleri depremi benzeştiren tersinir-tekrarlanır yükler altında test edilmiştir. Deney numuneleri Türkiye’deki betonarme yapılarda çoğunlukla gözlemlenen eksiklikleri yansıtacak şekilde üretilmiştir. İlk deney numunesi güçlendirme uygulaması yapılmamış referans numunedir. Diğer numuneler ise farklı pencere boşluk oranlarına ve konumuna sahip betonarme dolgu duvarlı numunelerdir. Yapılan deneylerin sonuçları betonarme dolgu duvarların, dayanım, rijitlik ve enerji tüketme üzerindeki etkilerini ortaya koyacak şekilde değerlendirilmiştir.  Deney sonuçları, betonarme dolgu duvarlı numunelerin, referans numuneden daha fazla yatay yük dayanımına, enerji tüketimine ve rijitliğe sahip olduğunu göstermiştir

    The Behavior of Strengthening 1/3 Scaled Reinforced Concrete Frames by Using Reinforced Concrete Shear Walls with Openings

    No full text
    Bu deneysel çalışmada, 1/3 ölçekli, tek açıklıklı, iki katlı, 6 adet betonarme çerçeve üretilmiş vepencere boşluklu veya boşluksuz dolgu duvar ile güçlendirilerek davranışları araştırılmıştır. Bu deneynumuneleri depremi benzeştiren tersinir-tekrarlanır yükler altında test edilmiştir. Deney numuneleriTürkiye’deki betonarme yapılarda çoğunlukla gözlemlenen eksiklikleri yansıtacak şekilde üretilmiştir.İlk deney numunesi güçlendirme uygulaması yapılmamış referans numunedir. Diğer numuneler isefarklı pencere boşluk oranlarına ve konumuna sahip betonarme dolgu duvarlı numunelerdir. Yapılandeneylerin sonuçları betonarme dolgu duvarların, dayanım, rijitlik ve enerji tüketme üzerindekietkilerini ortaya koyacak şekilde değerlendirilmiştir. Deney sonuçları, betonarme dolgu duvarlınumunelerin, referans numuneden daha fazla yatay yük dayanımına, enerji tüketimine ve rijitliğe sahipolduğunu göstermiştir.In this experimental study, 1/3 scaled, one-bay/two-storey, six reinforced concrete frames were constructed and tested to investigate the behavior of frames strengthened by introducing infills with or without openings. The test specimens were subjected to reversed cyclic loading simulating the seismic action. The specimens were constructed with the most commonly observed deficiencies in residential reinforced concrete buildings in Turkey. The first specimen was the reference specimen and contained no strengthening. The other specimens were infilled with reinforced concrete panels with openings having different ratios and configurations. Experimental results were evaluated to understand the effect of reinforced concrete infill wall on strength, stiffness and energy dissipation. The experimental results indicated that infilled RC frames shown higher lateral strength, energy dissipation and stiffness than the reference specimen considerably

    PENCERE BOŞLUKLU PERDE DUVARLA GÜÇLENDİRİLMİŞ 1/3 ÖLÇEKLİ BETONARME ÇERÇEVELERİN DAVRANIŞI

    No full text
    Bu deneysel çalışmada, 1/3 ölçekli, tek açıklıklı, iki katlı, 6 adet betonarme çerçeve üretilmiş vepencere boşluklu veya boşluksuz dolgu duvar ile güçlendirilerek davranışları araştırılmıştır. Bu deneynumuneleri depremi benzeştiren tersinir-tekrarlanır yükler altında test edilmiştir. Deney numuneleriTürkiye’deki betonarme yapılarda çoğunlukla gözlemlenen eksiklikleri yansıtacak şekilde üretilmiştir.İlk deney numunesi güçlendirme uygulaması yapılmamış referans numunedir. Diğer numuneler isefarklı pencere boşluk oranlarına ve konumuna sahip betonarme dolgu duvarlı numunelerdir. Yapılandeneylerin sonuçları betonarme dolgu duvarların, dayanım, rijitlik ve enerji tüketme üzerindekietkilerini ortaya koyacak şekilde değerlendirilmiştir. Deney sonuçları, betonarme dolgu duvarlınumunelerin, referans numuneden daha fazla yatay yük dayanımına, enerji tüketimine ve rijitliğe sahipolduğunu göstermiştir.In this experimental study, 1/3 scaled, one-bay/two-storey, six reinforced concrete frames were constructed and tested to investigate the behavior of frames strengthened by introducing infills with or without openings. The test specimens were subjected to reversed cyclic loading simulating the seismic action. The specimens were constructed with the most commonly observed deficiencies in residential reinforced concrete buildings in Turkey. The first specimen was the reference specimen and contained no strengthening. The other specimens were infilled with reinforced concrete panels with openings having different ratios and configurations. Experimental results were evaluated to understand the effect of reinforced concrete infill wall on strength, stiffness and energy dissipation. The experimental results indicated that infilled RC frames shown higher lateral strength, energy dissipation and stiffness than the reference specimen considerably