114,146 research outputs found

    Design and simulation of a multi-function MEMS sensor for health and usage monitoring.

    Get PDF
    Health and usage monitoring as a technique for online test, diagnosis or prognosis of structures and systems has evolved as a key technology for future critical systems. The technology, often referred to as HUMS is usually based around sensors that must be more reliable than the system or structure they are monitoring. This paper proposes a fault tolerant sensor architecture and demonstrates the feasibility of realising this architecture through the design of a dual mode humidity/pressure MEMS sensor with an integrated temperature function. The sensor has a simple structure, good linearity and sensitivity, and the potential for implementation of built-in-self-test features. We also propose a re-configurable sensor network based on the multi-functional sensor concept that supports both normal operational and fail safe modes. The architecture has the potential to significantly increase system reliability and supports a reduction in the number of sensors required in future HUMS devices. The technique has potential in a wide range of applications, especially within wireless sensor networks

    Implementation of packaged integrated antenna with embedded front end for Bluetooth applications

    No full text
    The design, integration and realization of system in enhanced package approach towards fully functional system level integration by using a compact Bluetooth USB dongle as the demonstrator is presented here. The integration was done on FR4 substrates, which is totally compatible with today’s printed circuit board manufacturing capability. A commercially available Bluetooth integrated chip was chosen as the chipset of our demonstrator, and a package integrated antenna together with an embedded front end completes the system in package integration. The front end developed here is based on an embedded meander line combline filter and an embedded transformer balun. The filter has a 35% area reduction when compared with the classical combline filter and similar performance. The balun has the coils distributed on three layers that minimized the board area needed it and optimizes the performances. The proposed packaged integrated antenna approach is successfully demonstrated here and the new module shows excellent performance when compared with a commercial solution, surpassing the normal Bluetooth class II dongle range which is up to 10 m and increasing the module range up to 120 m without an extra power amplifier

    Bridges Structural Health Monitoring and Deterioration Detection Synthesis of Knowledge and Technology

    Get PDF
    INE/AUTC 10.0

    Wireless ICS Training Platform

    Get PDF
    Indiana University - Purdue University IndianapolisEssential public services, such as Electric, Water and Gas Utilities, are becoming increasingly reliant on network connected devices to control their processes. Wireless control systems are becoming more common in distributed systems, since they offer many advantages over hard wired alternatives. While cyber physical systems such as PLCs offer many advantages, they are also vulnerable to cyber-attacks. Military force readiness for defense of critical infrastructure against cyber-attacks requires state of the industry industrial control systems for cyber security training. A remote terminal unit using broad spectrum radio was integrated into an existing Water Treatment Plant SCADA system and provided to the US Army for training.Electrical Engineering Technolog

    Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors

    Get PDF
    This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electrical LC tank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity (> 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies the in vivo bioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminary ex vivo experimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring

    Synchronous wearable wireless body sensor network composed of autonomous textile nodes

    Get PDF
    A novel, fully-autonomous, wearable, wireless sensor network is presented, where each flexible textile node performs cooperative synchronous acquisition and distributed event detection. Computationally efficient situational-awareness algorithms are implemented on the low-power microcontroller present on each flexible node. The detected events are wirelessly transmitted to a base station, directly, as well as forwarded by other on-body nodes. For each node, a dual-polarized textile patch antenna serves as a platform for the flexible electronic circuitry. Therefore, the system is particularly suitable for comfortable and unobtrusive integration into garments. In the meantime, polarization diversity can be exploited to improve the reliability and energy-efficiency of the wireless transmission. Extensive experiments in realistic conditions have demonstrated that this new autonomous, body-centric, textile-antenna, wireless sensor network is able to correctly detect different operating conditions of a firefighter during an intervention. By relying on four network nodes integrated into the protective garment, this functionality is implemented locally, on the body, and in real time. In addition, the received sensor data are reliably transferred to a central access point at the command post, for more detailed and more comprehensive real-time visualization. This information provides coordinators and commanders with situational awareness of the entire rescue operation. A statistical analysis of measured on-body node-to-node, as well as off-body person-to-person channels is included, confirming the reliability of the communication system

    Exploitation of Transparent Conductive Oxides in the Implementation of a Window-Integrated Wireless Sensor Node

    Full text link
    Exploitation of transparent conductive oxides (TCO) to implement an energy-autonomous sensor node for a wireless sensor network (WSN) is studied and a practical solution presented. In the practical implementations, flexible and rigid substrates that is polyimide and glass, are coated with TCO, namely aluminum doped zinc oxide (AZO). AZO-coated flexible substrates are used to form thermoelectric generators (TEG) that produce electricity for the sensor electronics of the node from thermal gradients on a window. As the second solution to utilize AZO, its conductive properties are exploited to implement transparent antennas for the sensor node. Antennas for a UHF RFID transponder and the Bluetooth radio of the node are implemented. A prototype of a flexible transparent TEG, with the area of 67 cm2 when folded, was measured to produce power of 1.6 uW with a temperature difference of 43 K. A radiation efficiency of -9.1 dB was measured for the transparent RFID antenna prototype with the center frequency of 900 MHz. Radiation efficiencies between -3.8 dB and -0.4 dB, depending on the substrate, were obtained for the 2.45 GHz Bluetooth antenna.Comment: 10 pages, 14 figures, last author version accepted for publication in IEEE Sensors Journa
    corecore