23,970 research outputs found

    Microwave Photoelasticity: A Resonant Wavelength Approach Applied to PEEK Polymer

    Get PDF
    Every nondestructive testing (NDT) technique has its unique set of advantages and limitations. Currently, the only existing noncontact NDT method capable of measuring sub-surface stresses, in optically opaque materials, at near-real-time speeds and over large areas is Microwave Photoelasticity (MP). This paper presents a new MP approach, which correlates changes in resonant wavelengths to changes in stress. In addition to a theoretical outline of the approach, the design and operation of an instrument capable of conducting these measurements is described. Finally, the technique is demonstrated by conducting measurements on polyetheretherketone, commonly known as PEEK, polymer. Between the W-Band frequencies of 105 to 115 GHz, PEEKs stress-optic-coefficient was determined to be of = 0.20 0.02 1/GPa

    Monitoring of liquid flow through microtubes using a micropressure sensor

    No full text
    The pressure-driven liquid flow through microtubes was studied in a range of very low Reynolds numbers (<0.15) by monitoring the pressure change in situ. Cylindrical microtubes with diameters ranging from 50 ?m to 500 ?m were examined and two types of tube material, namely PEEK polymer and fused silica were compared. A good linear relation for the pressure drop versus flow rate was obtained. Apparent deviations between the measured slopes with those calculated using conventional theory were attributed to uncertainties in the calculated values which are dominated by the uncertainties in the microtube diameters. It was found that a period of stabilisation time was required for reaching a steady flow after the syringe pump was switched on/off or to a different flow rate. The stabilisation time was likely due to the compressibility of the fluid. Insignificant difference between PEEK polymer and fused silica microtubes in terms of flow resistance was observed. The in-situ measurement of pressure drops provides a convenient approach for monitoring fluid flow through microtubes and detecting dimensional changes within microchannels in Lab-on-a-Chip and microreactor systems

    Spartan Daily, April 5, 1940

    Get PDF
    Volume 28, Issue 113https://scholarworks.sjsu.edu/spartandaily/3060/thumbnail.jp

    LaRC Aerothermodynamic Ground Tests in Support of BOLT Flight Experiment

    Get PDF
    A review is provided of recent aerothermodynamic ground-test contributions by NASA Langley Research Center (LaRC) to the BOLT flight test program. Several test entries into the Langley Aerothermodynamic Laboratory 20-Inch Mach 6 Air Tunnel are discussed. These entries were intended to support the development and design of flight hardware and instrumentation. Some trends and observations from these entries are provided. Also, a comparison of two different global heat transfer test techniques is included and discussed

    Design and performance of the muon monitor for the T2K neutrino oscillation experiment

    Full text link
    This article describes the design and performance of the muon monitor for the T2K (Tokaito-Kamioka) long baseline neutrino oscillation experiment. The muon monitor consists of two types of detector arrays: ionization chambers and silicon PIN photodiodes. It measures the intensity and profile of muons produced, along with neutrinos, in the decay of pions. The measurement is sensitive to the intensity and direction of the neutrino beam. The linearity and stability of the detectors were measured in beam tests to be within 2.4% and 1.5%, respectively. Based on the test results, the precision of the beam direction measured by the muon monitor is expected to be 0.25 mrad.Comment: 22 page
    corecore