    Effects of loading contact on electric-power generation of lead zirconate titanate piezoelectric ceramic plate

    Get PDF
    To better understand the generation of electric power for piezoelectric PbZrTiO3 (PZT) ceramic plate (phi 25 mm), an attempt was made to investigate experimentally and numerically electric-power generation characteristics during cyclic bending under various loading fixtures (phi 0-phi 20 mm), i.e., different contact areas. Increasing the load-contact area on the PZT ceramic leads to a nonlinear decrease in the generated voltage. Decreasing contact area basically enhances the generated voltage, although the voltage saturates during loading when the contact area is less than phi 5 mm. A similar voltage is generated for phi 0 and phi 5 mm, which is attributed to strain status (ratio of compressive and tensile strain) and material failure due to different stress distribution in the PZT ceramic. On the basis of the obtained electric generation voltage, suitable loading conditions are clarified by loading with the phi 5 mm fixture, which generates a higher voltage and a longer lifetime of the PZT ceramic. From this approach, it is appeared that the area contact with the area ratio of 0.04 (phi 5 mm/phi 20 mm) is suitable to obtain the high efficiency of the electric voltage

    The Generated Entropy Monitored by Pyroelectric Sensors

    No full text
    Entropy generation in irreversible processes is a critical issue that affects the failure and aging of electrical, chemical or mechanical systems. The promotion of energy conversion efficiency needs to reduce energy losses, namely to decrease entropy generation. A pyroelectric type of entropy detector is proposed to monitor energy conversion processes in real time. The entropy generation rate can be derived from the induced pyroelectric current, temperature, thermal capacity, pyroelectric coefficient and electrode area. It is profitable to design entropy detectors to maintain a small thermal capacity while pyroelectric sensors minimize geometrical dimensions. Moreover, decreasing the electrode area of the PZT cells could avoid affecting the entropy variation of the measured objects, but the thickness of the cells has to be greatly reduced to promote the temperature variation rate and strengthen the electrical signals. A commercial capacitor with a capacitance of 47 μF and a maximum endured voltage of 4 V were used to estimate the entropy to act as an indicator of the capacitors’ time-to-failure. The threshold time was evaluated by using the entropy generation rates at about 7.5 s, 11.25 s, 20 s and 30 s for the applied voltages of 40 V, 35 V, 30 V and 25 V respectively, while using a PZT cell with dimensions of 3 mm square and a thickness of 200 μm

    The Generated Entropy Monitored by Pyroelectric Sensors

    No full text
    Entropy generation in irreversible processes is a critical issue that affects the failure and aging of electrical, chemical or mechanical systems. The promotion of energy conversion efficiency needs to reduce energy losses, namely to decrease entropy generation. A pyroelectric type of entropy detector is proposed to monitor energy conversion processes in real time. The entropy generation rate can be derived from the induced pyroelectric current, temperature, thermal capacity, pyroelectric coefficient and electrode area. It is profitable to design entropy detectors to maintain a small thermal capacity while pyroelectric sensors minimize geometrical dimensions. Moreover, decreasing the electrode area of the PZT cells could avoid affecting the entropy variation of the measured objects, but the thickness of the cells has to be greatly reduced to promote the temperature variation rate and strengthen the electrical signals. A commercial capacitor with a capacitance of 47 μF and a maximum endured voltage of 4 V were used to estimate the entropy to act as an indicator of the capacitors’ time-to-failure. The threshold time was evaluated by using the entropy generation rates at about 7.5 s, 11.25 s, 20 s and 30 s for the applied voltages of 40 V, 35 V, 30 V and 25 V respectively, while using a PZT cell with dimensions of 3 mm square and a thickness of 200 μm
    corecore