156 research outputs found

    Penetrating 3-D Imaging at 4- and 25-m Range Using a Submillimeter-Wave Radar

    Get PDF
    We show experimentally that a high-resolution imaging radar operating at 576–605 GHz is capable of detecting weapons concealed by clothing at standoff ranges of 4–25 m. We also demonstrate the critical advantage of 3-D image reconstruction for visualizing hidden objects using active-illumination coherent terahertz imaging. The present system can image a torso with <1 cm resolution at 4 m standoff in about five minutes. Greater standoff distances and much higher frame rates should be achievable by capitalizing on the bandwidth, output power, and compactness of solid state Schottky-diode based terahertz mixers and multiplied sources

    Circuits Enhance Scientific Instruments and Safety Devices

    Get PDF
    Since its founding in 1958, NASA has pioneered the use of different frequencies on the electromagnetic spectrum - including X-ray, microwave, and infrared wavelengths - to gather information about distant celestial bodies. During the 1962 Mariner 2 mission, NASA used microwave radiometers that operated in the range of 15-23 gigahertz (GHz) to assess the surface temperature of Venus and to determine the percentage of water vapor in its atmosphere. Today, there is another area on the spectrum proving uniquely useful to scientists: the terahertz (THz) range, spanning from about 100 GHz-10,000 GHz. (1 THz equals approximately 1,000 GHz.) Terahertz frequencies span the lesser-known gap on the electromagnetic spectrum between microwave radiation and infrared (and visible) light, falling within the spectral range where most simple molecules resonate. This molecular resonance makes terahertz particularly useful for chemical spectroscopy and the remote sensing of specific molecules. In the 1990s, NASA began using frequencies above 300 GHz (more than an order of magnitude higher than the instrumentation on Mariner 2) to perform spectral analysis of molecular clouds and planetary atmospheres. Instruments using these higher frequencies have included the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS), deployed from 1991-2001, and the Microwave Instrument for the Rosetta Orbiter (MIRO), launched in 2004. With UARS-MLS, NASA used advanced terahertz receivers to measure the emission signatures from atmospheric molecules, providing researchers with valuable data about the changes in the Earth s protective ozone layer. MIRO, set to rendezvous with the comet 67P Churyumov-Gerasimenko in 2014, will use terahertz instrumentation to analyze the comet s dust and gases. Although NASA has been a driving force behind the development of terahertz technology, scientific equipment for terahertz research - including transmitters, receivers, and basic test and measurement equipment - is not widely available, making scientific experiments in this range between traditional electronics and quantum photonics more costly and greatly limiting commercial development in the field. Given NASA s interest in studying distant bodies in space as well as in improving life on Earth, the Agency has collaborated with private industry to develop terahertz technologies

    The PLATO Dome A Site-Testing Observatory : instrumentation and first results

    Get PDF
    The PLATeau Observatory (PLATO) is an automated self-powered astrophysical observatory that was deployed to Dome A, the highest point on the Antarctic plateau, in 2008 January. PLATO consists of a suite of site-testing instruments designed to quantify the benefits of the Dome A site for astronomy, and science instruments designed to take advantage of the unique observing conditions. Instruments include CSTAR, an array of optical telescopes for transient astronomy; Gattini, an instrument to measure the optical sky brightness and cloud cover statistics; DASLE, an experiment to measure the statistics of the meteorological conditions within the near-surface layer; Pre-HEAT, a submillimeter tipping radiometer measuring the atmospheric transmission and water vapor content and performing spectral line imaging of the Galactic plane; and Snodar, an acoustic radar designed to measure turbulence within the near-surface layer. PLATO has run completely unattended and collected data throughout the winter 2008 season. Here we present a detailed description of the PLATO instrument suite and preliminary results obtained from the first season of operation

    NASA Tech Briefs, July 2012

    Get PDF
    Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage

    A tunable cavity-locked diode laser source for terahertz photomixing

    Get PDF
    An all solid-state approach to the precise frequency synthesis and control of widely tunable terahertz radiation by differencing continuous-wave diode lasers at 850 nm is reported in this paper. The difference frequency is synthesized by three fiber-coupled external-cavity laser diodes. Two of the lasers are Pound-Drever-Hall locked to different orders of a Fabry-Perot (FP) cavity, and the third is offset-frequency locked to the second of the cavity-locked lasers using a tunable microwave oscillator. The first cavity-locked laser and the offset-locked laser produce the difference frequency, whose value is accurately determined by the sum of an integer multiple of the free spectral range of the FP cavity and the offset frequency. The dual-frequency 850-nm output of the three laser system is amplified to 500 mW through two-frequency injection seeding of a single semiconductor tapered optical amplifier. As proof of precision frequency synthesis and control of tunability, the difference frequency is converted into a terahertz wave by optical-heterodyne photomixing in low-temperature-grown GaAs and used for the spectroscopy of simple molecules. The 3-dB spectral power bandwidth of the terahertz radiation is routinely observed to be ≾1 MHz. A simple, but highly accurate, method of obtaining an absolute frequency calibration is proposed and an absolute calibration of 10^(-7) demonstrated using the known frequencies of carbon monoxide lines between 0.23-1.27 THz

    Low-cost CW-LFM radar sensor at 100 GHz

    Get PDF
    This paper presents a W-band high-resolution radar sensor for short-range applications. Low-cost technologies have been properly selected in order to implement a versatile and easily scalable radar system. A large operational bandwidth of 9 GHz, required for obtaining high-range resolution, is attained by means of a frequency multiplication-based architecture. The system characterization to identify the performance-limiting stages and the subsequent design optimization are presented. The assessment of system performance for several representative applications has been carried out

    Review: far-infrared instrumentation and technological development for the next decade

    Get PDF
    Far-infrared astronomy has advanced rapidly since its inception in the late 1950s, driven by a maturing technology base and an expanding community of researchers. This advancement has shown that observations at far-infrared wavelengths are important in nearly all areas of astrophysics, from the search for habitable planets and the origin of life to the earliest stages of galaxy assembly in the first few hundred million years of cosmic history. The combination of a still-developing portfolio of technologies, particularly in the field of detectors, and a widening ensemble of platforms within which these technologies can be deployed, means that far-infrared astronomy holds the potential for paradigm-shifting advances over the next decade. We examine the current and future far-infrared observing platforms, including ground-based, suborbital, and space-based facilities, and discuss the technology development pathways that will enable and enhance these platforms to best address the challenges facing far-infrared astronomy in the 21st century

    CASIMIR, The Caltech airborne submillimeter interstellar medium investigations receiver

    Get PDF
    CASIMIR, the Caltech Airborne Submillimeter Interstellar Medium Investigations Receiver is a multiband, far infrared and submillimeter, high resolution, heterodyne spectrometer under development for SOFIA. It is a first generation, PI class instrument. CASIMIR is designed for detailed, high sensitivity observations of warm (100 K) interstellar gas both in external galaxies and Galactic sources, including molecular clouds, circumstellar envelopes, and protostellar cores. Combining the 2.5 m SOFIA mirror with state of the art superconducting mixers, will give CASIMIR unprecedented sensitivity. Initially, CASIMIR will have two bands, at 1000 and 1250 GHz, and a further three bands, 550, 750, 1400 GHz, will be added soon after. Any four bands will be available on each flight. The availability of multiple bands during each flight will allow for efficient use of flight time. For example, searches for weak lines from rare species in bright sources can be carried out on the same flight with observations of abundant species in faint or distant objects
    corecore