4 research outputs found

    Sampling frequency influences sample entropy of kinematics during walking

    Get PDF
    Sample entropy (SaEn) has been used to assess the regularity of lower limb joint angles during walking. However, changing sampling frequency and the number of included strides can potentially affect the sample entropy. The present study investigated the effect of sample frequency and the number of included strides on the calculations of SaEn in joint angle signals recorded during treadmill walking. Eleven subjects walked at their preferred walking speed for 10 minutes, and SaEn was calculated on sagittal plane hip, knee and ankle angle signals extracted from 50, 100, 200, 300 and 400 strides at sampling frequencies of 60, 120, 240 and 480Hz. Increase in sampling frequency decreased the SaEn significantly for the three joints. The number of included strides had no effect on the SaEn calculated on the hip joint angle and only limited effect on the SaEn calculated on the knee and ankle joint signals. The present study suggests that the number of data points within each stride to a greater extent determines the size of the SaEn compared to the number of strides and emphasizes the use of a fixed number of data points within each stride when applying SaEn to lower limb joint angles during walking

    On the Calculation of Sample Entropy Using Continuous and Discrete Human Gait Data

    Get PDF
    Sample entropy (SE) has relative consistency using biologically-derived, discrete data \u3e500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r(tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480 Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60 Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE
    corecore