12,300 research outputs found
RETRACTED: A review on mindfulness and nursing stress among nurses
RETRACTION TO:Said, Z., & Kheng, G. L. (2018). A review on mindfulness and nursing stress among nurses. COUNS-EDU: The International Journal of Counseling and Education, 3(1), 1-13. (doi: https://doi.org/10.23916/0020170211740This article has been retracted by Publisher based on the following reason:The Editor of COUNS-EDU: The International Journal of Counseling and Education found the double publication in the article publishing due to article's content similarity published in http://ojs.uma.ac.id/index.php/analitika/article/view/1589.Said, Z., & Kheng, G. L. (2018). A review on mindfulness and nursing stress among nurses. ANALITIKA, 10 (1), 31-45,One of the conditions of submission of paper for publication in this journal is that authors declare explicitly that their work is original and has not appeared in a publication elsewhere. Re-use of any data should be appropriately cited. As such this article represents a severe abuse of the scientific publishing system. The scientific community takes a very strong view on this matter and apologies are offered to readers of the journal that this was not detected during the submission proces
Reproducibility of lymphovascular space invasion (LVSI) assessment in endometrial cancer
Aims Lymphovascular space invasion (LVSI) in endometrial cancer (EC) is an important prognostic variable impacting on a patient's individual recurrence risk and adjuvant treatment recommendations. Recent work has shown that grading the extent of LVSI further improves its prognostic strength in patients with stage I endometrioid EC. Despite this, there is little information on the reproducibility of LVSI assessment in EC. Therefore, we designed a study to evaluate interobserver agreement in discriminating true LVSI from LVSI mimics (Phase I) and reproducibility of grading extent of LVSI (Phase II). Methods and results Scanned haematoxylin and eosin (H&E) slides of endometrioid EC (EEC) with a predefined possible LVSI focus were hosted on a website and assessed by a panel of six European gynaecological pathologists. In Phase I, 48 H&E slides were included for LVSI assessment and in Phase II, 42 H&E slides for LVSI grading. Each observer was instructed to apply the criteria for LVSI used in daily practice. The degree of agreement was measured using the two-way absolute agreement average-measures intraclass correlation coefficient (ICC). Reproducibility of LVSI assessment (ICC = 0.64, P < 0.001) and LVSI grading (ICC = 0.62, P < 0.001) in EEC was substantial among the observers. Conclusions Given the good reproducibility of LVSI, this study further supports the important role of LVSI in decision algorithms for adjuvant treatment
Flexible radiator system: Executive summary
A full scale prototype flexible radiator panel was designed, built and tested. The panel, has approximately 173 sq ft of radiating area and is designed to reject 1.33 kW of heat to a 0 F sink with a 100 F fluid inlet. The panel is constructed from a flexible Teflon/silver mesh fin surrounding 1/8 inch Teflon tubes. The prototype panel is stowed on a 10 inch diameter by 4 foot wide drum. (It rolls up to a diameter of 17 inches when fully stowed). Deployment of the soft tube prototype is via two four inch diameter Kevlar/Mylar inflation tubes with flat springs incorporated in each tube. Nitrogen is normally used for the deployment with approximately 1 psi required. The springs retract the panels when the inflation tubes are deflated. Another method of deployment available for the soft tube flexible is a motor driven deployable boom. This eliminates the need for expendables when the panel area is varied during the mission for heat load control. The soft tube panel is designed for a 90% probability of no punctured tube in a 30 day mission. The acceptable working fluids for this soft tube flexible are Coolanol 15, Coolanol 20 and Glycol/water (a eutectic mixture)
Development of deployable structures for large space platform systems. Volume 1: Executive summary
The preponderance of study effort was devoted toward the deployable platform systems study which culminated in the detailed design of a ground test article for future development testing. This design is representative of a prototype square-truss, single-fold building-block design that can construct deployable platform structures. This prototype design was selected through a comprehensive and traceable selection process applied to eight competitive designs. The selection process compared the competitive designs according to seven major selection criteria, i.e., design versatility, cost, thermal stability, meteoroid impact significance, reliability, performance predictability, and orbiter integration suitability. In support of the foregoing, a materials data base, and platform systems technology development needs were established. An erectable design of an OTV hangar was selected and recommended for further design development. This design was selected from five study-developed competitive single-fold and double-fold designs including hard-shell and inflatable designs. Also, two deployable manned module configurations, i.e., a hard-shell and an inflatable design were each developed to the same requirements as the composite of two Space station baseline habitat modules
Quantification of Cell Movement Reveals Distinct Edge Motility Types During Cell Spreading
Actin-based motility is central to cellular processes such as migration, bacterial engulfment, and cancer metastasis, and requires precise spatial and temporal regulation of the cytoskeleton. We studied one such process, fibroblast spreading, which involves three temporal phases: early, middle, and late spreading, distinguished by differences in cell area growth. In these studies, aided by improved algorithms for analyzing edge movement, we observed that each phase was dominated by a single, kinematically and biochemically distinct cytoskeletal organization, or motility type. Specifically, early spreading was dominated by periodic blebbing; continuous protrusion occurred predominantly during middle spreading; and periodic contractions were prevalent in late spreading. Further characterization revealed that each motility type exhibited a distinct distribution of the actin-related protein VASP, while inhibition of actin polymerization by cytochalasin D treatment revealed different dependences on barbed-end polymerization. Through this detailed characterization and graded perturbation of the system, we observed that although each temporal phase of spreading was dominated by a single motility type, in general cells exhibited a variety of motility types in neighboring spatial domains of the plasma membrane edge. These observations support a model in which global signals bias local cytoskeletal biochemistry in favor of a particular motility type
Large diameter astromast development, phase 1
Coilable-longeron lattice columns called Astromasts (trademark) were manufactured for a variety of spacecraft missions. These flight structures varied in diameter from 0.2 to 0.5 meter (9 to 19 in.), and the longest Astromast of this type deploys to a length of 30 meters (100 feet). A double-laced diagonal Astromast design referred to as the Supermast (trademark) which, because it has shorter baylengths than an Astromast, is approximately four times as strong. The longeron cross section and composite material selection for these structures are limited by the maximum strain associated with stowage and deployment. As a result, future requirements for deployable columns with high stiffness and strength require the development of both structures in larger diameters. The design, development, and manufacture of a 6.1-m-long (20-ft), 0.75-m-diameter (30-in.), double-laced diagonal version of the Astromast is described
A study’s got to know its limitations
Background: All research has room for improvement, but authors do not always clearly acknowledge the limitations of their work. In this brief report, we sought to identify the prevalence of limitations statements in the medRxiv COVID-19 SARS-CoV-2 dataset. Methods: We combined automated methods with manual review to analyse manuscripts for the presence, or absence, either of a defined limitations section in the text, or as part of the general discussion. Results: We identified a structured limitations statement in 28% of the manuscripts, and overall 52% contained at least one mention of a study limitation. Over one-third of manuscripts contained none of the terms that might typically be associated with reporting of limitations. Overall our method performed with precision of 0.97 and recall of 0.91. Conclusion: The presence or absence of limitations statements can be identified with reasonable confidence using automated tools. We suggest that it might be beneficial to require a defined, structured statement about study limitations, either as part of the submission process, or clearly delineated within the manuscript
- …
