Fast, Iterative Image Reconstruction for MRI in the Presence of Field Inhomogeneities
In magnetic resonance imaging, magnetic field inhomogeneities cause distortions in images that are reconstructed by conventional fast Fourier transform (FFT) methods. Several noniterative image reconstruction methods are used currently to compensate for field inhomogeneities, but these methods assume that the field map that characterizes the off-resonance frequencies is spatially smooth. Recently, iterative methods have been proposed that can circumvent this assumption and provide improved compensation for off-resonance effects. However, straightforward implementations of such iterative methods suffer from inconveniently long computation times. This paper describes a tool for accelerating iterative reconstruction of field-corrected MR images: a novel time-segmented approximation to the MR signal equation. We use a min-max formulation to derive the temporal interpolator. Speedups of around 60 were achieved by combining this temporal interpolator with a nonuniform fast Fourier transform with normalized root mean squared approximation errors of 0.07%. The proposed method provides fast, accurate, field-corrected image reconstruction even when the field map is not smooth.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/86010/1/Fessler69.pd
Shearlet-based compressed sensing for fast 3D cardiac MR imaging using iterative reweighting
High-resolution three-dimensional (3D) cardiovascular magnetic resonance
(CMR) is a valuable medical imaging technique, but its widespread application
in clinical practice is hampered by long acquisition times. Here we present a
novel compressed sensing (CS) reconstruction approach using shearlets as a
sparsifying transform allowing for fast 3D CMR (3DShearCS). Shearlets are
mathematically optimal for a simplified model of natural images and have been
proven to be more efficient than classical systems such as wavelets. Data is
acquired with a 3D Radial Phase Encoding (RPE) trajectory and an iterative
reweighting scheme is used during image reconstruction to ensure fast
convergence and high image quality. In our in-vivo cardiac MRI experiments we
show that the proposed method 3DShearCS has lower relative errors and higher
structural similarity compared to the other reconstruction techniques
especially for high undersampling factors, i.e. short scan times. In this
paper, we further show that 3DShearCS provides improved depiction of cardiac
anatomy (measured by assessing the sharpness of coronary arteries) and two
clinical experts qualitatively analyzed the image quality
- …