6 research outputs found

    Human Iris Recognition in Post-mortem Subjects: Study and Database

    Full text link
    This paper presents a unique study of post-mortem human iris recognition and the first known to us database of near-infrared and visible-light iris images of deceased humans collected up to almost 17 days after death. We used four different iris recognition methods to analyze the dynamics of iris quality decay in short-term comparisons (samples collected up to 60 hours after death) and long-term comparisons (for samples acquired up to 407 hours after demise). This study shows that post-mortem iris recognition is possible and occasionally works even 17 days after death. These conclusions contradict a promulgated rumor that iris is unusable shortly after decease. We make this dataset publicly available to let others verify our findings and to research new aspects of this important and unfamiliar topic. We are not aware of any earlier papers offering post-mortem human iris images and such comprehensive analysis employing four different matchers.Comment: Accepted manuscript version of the BTAS2016 pape

    Iris Recognition Under Biologically Troublesome Conditions - Effects of Aging, Diseases and Post-mortem Changes

    Full text link
    This paper presents the most comprehensive analysis of iris recognition reliability in the occurrence of various biological processes happening naturally and pathologically in the human body, including aging, illnesses, and post-mortem changes to date. Insightful conclusions are offered in relation to all three of these aspects. Extensive regression analysis of the template aging phenomenon shows that differences in pupil dilation, combined with certain quality factors of the sample image and the progression of time itself can significantly degrade recognition accuracy. Impactful effects can also be observed when iris recognition is employed with eyes affected by certain eye pathologies or (even more) with eyes of the deceased subjects. Notably, appropriate databases are delivered to the biometric community to stimulate further research in these utterly important areas of iris biometrics studies. Finally, some open questions are stated to inspire further discussions and research on these important topics. To Authors' best knowledge, this is the only scientific study of iris recognition reliability of such a broad scope and novelty.Comment: Accepted manuscript version of the BIOSIGNALS 2017 pape

    Post-mortem Human Iris Recognition

    Full text link
    This paper presents a unique analysis of post-mortem human iris recognition. Post-mortem human iris images were collected at the university mortuary in three sessions separated by approximately 11 hours, with the first session organized from 5 to 7 hours after demise. Analysis performed for four independent iris recognition methods shows that the common claim of the iris being useless for biometric identification soon after death is not entirely true. Since the pupil has a constant and neutral dilation after death (the so called "cadaveric position"), this makes the iris pattern perfectly visible from the standpoint of dilation. We found that more than 90% of irises are still correctly recognized when captured a few hours after death, and that serious iris deterioration begins approximately 22 hours later, since the recognition rate drops to a range of 13.3-73.3% (depending on the method used) when the cornea starts to be cloudy. There were only two failures to enroll (out of 104 images) observed for only a single method (out of four employed in this study). These findings show that the dynamics of post-mortem changes to the iris that are important for biometric identification are much more moderate than previously believed. To the best of our knowledge, this paper presents the first experimental study of how iris recognition works after death, and we hope that these preliminary findings will stimulate further research in this area.Comment: Accepted for publication version of the manuscript submitted for the IEEE ICB 201

    Post-mortem Iris Decomposition and its Dynamics in Morgue Conditions

    Full text link
    With increasing interest in employing iris biometrics as a forensic tool for identification by investigation authorities, there is a need for a thorough examination and understanding of post-mortem decomposition processes that take place within the human eyeball, especially the iris. This can prove useful for fast and accurate matching of ante-mortem with post-mortem data acquired at crime scenes or mass casualties, as well as for ensuring correct dispatching of bodies from the incident scene to a mortuary or funeral homes. Following these needs of forensic community, this paper offers an analysis of the coarse effects of eyeball decay done from a perspective of automatic iris recognition point of view. Therefore, we analyze post-mortem iris images acquired in both visible light as well as in near-infrared light (860 nm), as the latter wavelength is used in commercial iris recognition systems. Conclusions and suggestions are provided that may aid forensic examiners in successfully utilizing iris patterns in post-mortem identification of deceased subjects. Initial guidelines regarding the imaging process, types of illumination, resolution are also given, together with expectations with respect to the iris features decomposition rates

    Post-mortem Iris Recognition with Deep-Learning-based Image Segmentation

    Full text link
    This paper proposes the first known to us iris recognition methodology designed specifically for post-mortem samples. We propose to use deep learning-based iris segmentation models to extract highly irregular iris texture areas in post-mortem iris images. We show how to use segmentation masks predicted by neural networks in conventional, Gabor-based iris recognition method, which employs circular approximations of the pupillary and limbic iris boundaries. As a whole, this method allows for a significant improvement in post-mortem iris recognition accuracy over the methods designed only for ante-mortem irises, including the academic OSIRIS and commercial IriCore implementations. The proposed method reaches the EER less than 1% for samples collected up to 10 hours after death, when compared to 16.89% and 5.37% of EER observed for OSIRIS and IriCore, respectively. For samples collected up to 369 hours post-mortem, the proposed method achieves the EER 21.45%, while 33.59% and 25.38% are observed for OSIRIS and IriCore, respectively. Additionally, the method is tested on a database of iris images collected from ophthalmology clinic patients, for which it also offers an advantage over the two other algorithms. This work is the first step towards post-mortem-specific iris recognition, which increases the chances of identification of deceased subjects in forensic investigations. The new database of post-mortem iris images acquired from 42 subjects, as well as the deep learning-based segmentation models are made available along with the paper, to ensure all the results presented in this manuscript are reproducible.Comment: Paper submitted for the Elsevier Image and Vision Computing Journal on Jan 5th, 2019, revised versio

    Iris recognition in cases of eye pathology

    Full text link
    This chapter provides insight on how iris recognition, one of the leading biometric identification technologies in the world, can be impacted by pathologies and illnesses present in the eye, what are the possible repercussions of this influence, and what are the possible means for taking such effects into account when matching iris samples. To make this study possible, a special database of iris images has been used, representing more than 20 different medical conditions of the ocular region (including cataract, glaucoma, rubeosis iridis, synechiae, iris defects, corneal pathologies and other) and containing almost 3000 samples collected from 230 distinct irises. Then, with the use of four different iris recognition methods, a series of experiments has been conducted, concluding in several important observations. One of the most popular ocular disorders worldwide - the cataract - is shown to worsen genuine comparison scores when results obtained from cataract-affected eyes are compared to those coming from healthy irises. An analysis devoted to different types of impact on eye structures caused by diseases is also carried out with significant results. The enrollment process is highly sensitive to those eye conditions that make the iris obstructed or introduce geometrical distortions. Disorders affecting iris geometry, or producing obstructions are exceptionally capable of degrading the genuine comparison scores, so that the performance of the entire biometric system can be influenced. Experiments also reveal that imperfect execution of the image segmentation stage is the most prominent contributor to recognition errors.Comment: Accepted for publication as a chapter in A. Nait-Ali (Ed.), "Biometrics under Biomedical Considerations", Springer, 2019, ISBN 978-981-13-1143-
    corecore