13,788 research outputs found
A Study of Medium Access Control Protocols for Wireless Body Area Networks
The seamless integration of low-power, miniaturised, invasive/non-invasive
lightweight sensor nodes have contributed to the development of a proactive and
unobtrusive Wireless Body Area Network (WBAN). A WBAN provides long-term health
monitoring of a patient without any constraint on his/her normal dailylife
activities. This monitoring requires low-power operation of
invasive/non-invasive sensor nodes. In other words, a power-efficient Medium
Access Control (MAC) protocol is required to satisfy the stringent WBAN
requirements including low-power consumption. In this paper, we first outline
the WBAN requirements that are important for the design of a low-power MAC
protocol. Then we study low-power MAC protocols proposed/investigated for WBAN
with emphasis on their strengths and weaknesses. We also review different
power-efficient mechanisms for WBAN. In addition, useful suggestions are given
to help the MAC designers to develop a low-power MAC protocol that will satisfy
the stringent WBAN requirements.Comment: 13 pages, 8 figures, 7 table
A Review of Wireless Body Area Networks for Medical Applications
Recent advances in Micro-Electro-Mechanical Systems (MEMS) technology,
integrated circuits, and wireless communication have allowed the realization of
Wireless Body Area Networks (WBANs). WBANs promise unobtrusive ambulatory
health monitoring for a long period of time and provide real-time updates of
the patient's status to the physician. They are widely used for ubiquitous
healthcare, entertainment, and military applications. This paper reviews the
key aspects of WBANs for numerous applications. We present a WBAN
infrastructure that provides solutions to on-demand, emergency, and normal
traffic. We further discuss in-body antenna design and low-power MAC protocol
for WBAN. In addition, we briefly outline some of the WBAN applications with
examples. Our discussion realizes a need for new power-efficient solutions
towards in-body and on-body sensor networks.Comment: 7 pages, 7 figures, and 3 tables. In V3, the manuscript is converted
to LaTe
Adaptive Duty Cycling MAC Protocols Using Closed-Loop Control for Wireless Sensor Networks
The fundamental design goal of wireless sensor MAC protocols is to minimize unnecessary power consumption of the sensor nodes, because of its stringent resource constraints and ultra-power limitation. In existing MAC protocols in wireless sensor networks (WSNs), duty cycling, in which each node periodically cycles between the active and sleep states, has been introduced to reduce unnecessary energy consumption. Existing MAC schemes, however, use a fixed duty cycling regardless of multi-hop communication and traffic fluctuations. On the other hand, there is a tradeoff between energy efficiency and delay caused by duty cycling mechanism in multi-hop communication and existing MAC approaches only tend to improve energy efficiency with sacrificing data delivery delay. In this paper, we propose two different MAC schemes (ADS-MAC and ELA-MAC) using closed-loop control in order to achieve both energy savings and minimal delay in wireless sensor networks. The two proposed MAC schemes, which are synchronous and asynchronous approaches, respectively, utilize an adaptive timer and a successive preload frame with closed-loop control for adaptive duty cycling. As a result, the analysis and the simulation results show that our schemes outperform existing schemes in terms of energy efficiency and delivery delay
Distance Aware Relaying Energy-efficient: DARE to Monitor Patients in Multi-hop Body Area Sensor Networks
In recent years, interests in the applications of Wireless Body Area Sensor
Network (WBASN) is noticeably developed. WBASN is playing a significant role to
get the real time and precise data with reduced level of energy consumption. It
comprises of tiny, lightweight and energy restricted sensors, placed in/on the
human body, to monitor any ambiguity in body organs and measure various
biomedical parameters. In this study, a protocol named Distance Aware Relaying
Energy-efficient (DARE) to monitor patients in multi-hop Body Area Sensor
Networks (BASNs) is proposed. The protocol operates by investigating the ward
of a hospital comprising of eight patients, under different topologies by
positioning the sink at different locations or making it static or mobile.
Seven sensors are attached to each patient, measuring different parameters of
Electrocardiogram (ECG), pulse rate, heart rate, temperature level, glucose
level, toxins level and motion. To reduce the energy consumption, these sensors
communicate with the sink via an on-body relay, affixed on the chest of each
patient. The body relay possesses higher energy resources as compared to the
body sensors as, they perform aggregation and relaying of data to the sink
node. A comparison is also conducted conducted with another protocol of BAN
named, Mobility-supporting Adaptive Threshold-based Thermal-aware
Energy-efficient Multi-hop ProTocol (M-ATTEMPT). The simulation results show
that, the proposed protocol achieves increased network lifetime and efficiently
reduces the energy consumption, in relative to M-ATTEMPT protocol.Comment: IEEE 8th International Conference on Broadband and Wireless
Computing, Communication and Applications (BWCCA'13), Compiegne, Franc
Transmission Delay of Multi-hop Heterogeneous Networks for Medical Applications
Nowadays, with increase in ageing population, Health care market keeps
growing. There is a need for monitoring of Health issues. Body Area Network
consists of wireless sensors attached on or inside human body for monitoring
vital Health related problems e.g, Electro Cardiogram (ECG),
ElectroEncephalogram (EEG), ElectronyStagmography(ENG) etc. Data is recorded by
sensors and is sent towards Health care center. Due to life threatening
situations, timely sending of data is essential. For data to reach Health care
center, there must be a proper way of sending data through reliable connection
and with minimum delay. In this paper transmission delay of different paths,
through which data is sent from sensor to Health care center over heterogeneous
multi-hop wireless channel is analyzed. Data of medical related diseases is
sent through three different paths. In all three paths, data from sensors first
reaches ZigBee, which is the common link in all three paths. After ZigBee there
are three available networks, through which data is sent. Wireless Local Area
Network (WLAN), Worldwide Interoperability for Microwave Access (WiMAX),
Universal Mobile Telecommunication System (UMTS) are connected with ZigBee.
Each network (WLAN, WiMAX, UMTS) is setup according to environmental
conditions, suitability of device and availability of structure for that
device. Data from these networks is sent to IP-Cloud, which is further
connected to Health care center. Main aim of this paper is to calculate delay
of each link in each path over multihop wireless channel.Comment: BioSPAN with 7th IEEE International Conference on Broadband and
Wireless Computing, Communication and Applications (BWCCA 2012), Victoria,
Canada, 201
Analyzing Delay in Wireless Multi-hop Heterogeneous Body Area Networks
With increase in ageing population, health care market keeps growing. There
is a need for monitoring of health issues. Wireless Body Area Network (WBAN)
consists of wireless sensors attached on or inside human body for monitoring
vital health related problems e.g, Electro Cardiogram (ECG), Electro
Encephalogram (EEG), ElectronyStagmography (ENG) etc. Due to life threatening
situations, timely sending of data is essential. For data to reach health care
center, there must be a proper way of sending data through reliable connection
and with minimum delay. In this paper transmission delay of different paths,
through which data is sent from sensor to health care center over heterogeneous
multi-hop wireless channel is analyzed. Data of medical related diseases is
sent through three different paths. In all three paths, data from sensors first
reaches ZigBee, which is the common link in all three paths. Wireless Local
Area Network (WLAN), Worldwide Interoperability for Microwave Access (WiMAX),
Universal Mobile Telecommunication System (UMTS) are connected with ZigBee.
Each network (WLAN, WiMAX, UMTS) is setup according to environmental
conditions, suitability of device and availability of structure for that
device. Data from these networks is sent to IP-Cloud, which is further
connected to health care center. Delay of data reaching each device is
calculated and represented graphically. Main aim of this paper is to calculate
delay of each link in each path over multi-hop wireless channel.Comment: arXiv admin note: substantial text overlap with arXiv:1208.240
SIMPLE: Stable Increased-throughput Multi-hop Protocol for Link Efficiency in Wireless Body Area Networks
In this work, we propose a reliable, power efficient and high throughput
routing protocol for Wireless Body Area Networks (WBANs). We use multi-hop
topology to achieve minimum energy consumption and longer network lifetime. We
propose a cost function to select parent node or forwarder. Proposed cost
function selects a parent node which has high residual energy and minimum
distance to sink. Residual energy parameter balances the energy consumption
among the sensor nodes while distance parameter ensures successful packet
delivery to sink. Simulation results show that our proposed protocol maximize
the network stability period and nodes stay alive for longer period. Longer
stability period contributes high packet delivery to sink which is major
interest for continuous patient monitoring.Comment: IEEE 8th International Conference on Broadband and Wireless
Computing, Communication and Applications (BWCCA'13), Compiegne, Franc
- …