40,184 research outputs found

    Development of Optical Biosensor Technologies for Cardiac Troponin Recognition

    Get PDF
    Acute myocardial infarction (AMI) is the leading cause of death among cardiovascular diseases. Among the numerous attempts to develop coronary marker concepts into clinical strategies, cardiac troponin is known as a specific marker for coronary events. The cardiac troponin concentration level in blood has been shown to rise rapidly for 4–10 days after onset of AMI, making it an attractive approach for a long diagnosis window for detection. The extremely low clinical sensing range of cardiac troponin levels consequently makes the methods of detection highly sensitive. In this review, by taking into consideration optical methods applied for cardiac troponin detection, we discuss the most commonly used methods of optical immunosensing and provide an overview of the various diagnostic cardiac troponin immunosensors that have been employed for determination of cardiac troponin over the last several years

    Integrated optical directional coupler biosensor

    No full text
    We present measurements on biomolecular binding reactions, using a new type of integrated optical biosensor based on a planar directional coupler structure. The device is fabricated by Ag+-Na+ ion-exchange in glass and definition of the sensing region is achieved by use of transparent fluoropolymer isolation layers formed by thermal evaporation. The suitability of the sensor for application to the detection of environmental pollutants is considered

    Nanomaterials for Healthcare Biosensing Applications

    Get PDF
    In recent years, an increasing number of nanomaterials have been explored for their applications in biomedical diagnostics, making their applications in healthcare biosensing a rapidly evolving field. Nanomaterials introduce versatility to the sensing platforms and may even allow mobility between different detection mechanisms. The prospect of a combination of different nanomaterials allows an exploitation of their synergistic additive and novel properties for sensor development. This paper covers more than 290 research works since 2015, elaborating the diverse roles played by various nanomaterials in the biosensing field. Hence, we provide a comprehensive review of the healthcare sensing applications of nanomaterials, covering carbon allotrope-based, inorganic, and organic nanomaterials. These sensing systems are able to detect a wide variety of clinically relevant molecules, like nucleic acids, viruses, bacteria, cancer antigens, pharmaceuticals and narcotic drugs, toxins, contaminants, as well as entire cells in various sensing media, ranging from buffers to more complex environments such as urine, blood or sputum. Thus, the latest advancements reviewed in this paper hold tremendous potential for the application of nanomaterials in the early screening of diseases and point-of-care testing

    Biosensor assay for determination of haptoglobin in bovine milk

    Get PDF
    Despite more than 30 years of research into mastitis diagnostics, there are few alternatives to the somatic cell count (SCC) in practical use for identification of cows with subclinical mastitis. Mastitis is not only an animal welfare problem, but also affects the yield, composition and technological properties of milk. Hence, dairy cooperatives give farmers a premium quality payment to encourage low SCC although there is no clear scientific data defining the level of SCC in bulk tank milk that is associated with additional benefits in terms of milk quality. Recent research on alternative markers for inflammatory reactions in the lactating cow, e.g. in mastitis, includes investigations of the acute phase protein, haptoglobin (Hp). So far, the content of Hp in milk has mainly been studied in relation to mastitis diagnostics, with little attention given to its importance for milk composition and technological properties. At present, Hp in milk is measured using ELISA, but this technique is not suitable for routine large-scale analysis. In recent years, optical biosensor technology has been used for automated and rapid quantitative analysis of different components in milk, but so far not for analysis of acute phase proteins. The aim of the present study was to develop a rapid and sensitive biosensor method to determine Hp in milk. An affinity sensor assay based on the interaction between Hp and haemoglobin was developed using surface plasmon resonance (SPR) biosensor technology. The assay was used to analyse Hp in composite milk samples from cows without any clinical signs of mastitis and quarter milk samples with a weak to strong reaction in the California Mastitis Test (CMT). A commercial ELISA for determination of Hp in milk was used for comparison. The limit of detection (LOD) of the biosensor assay was determined as 1.1 mg/l. Within-assay and betweenday variations were determined both with bulk tank milk spiked with human Hp and with composite milk samples containing bovine Hp. Coefficients of variation varied between 3.6 and 8.6% at concentrations between 4.0 and 12 mg/l, respectively. Agreement between the results obtained by the biosensor assay and the ELISA was satisfactory ; however, the results obtained by the biosensor were generally lower than the results obtained by the ELISA. Possible explanations for this observation are discussed

    A plasmonic accuracy biosensor using a single laser diode

    Get PDF
    A theoretical model was implemented to obtain the total specular reflection of a variable external multicavity for out of normal incidence and different polarisations. The model was theoretically and experimentally validated and a further analysis was applied to the study of the stability of the SMI signal. It was found that out of normal incidence, or the use of different polarisations does not affect the quality of the signal in a relevant manner

    Applications of Graphene Quantum Dots in Biomedical Sensors

    Get PDF
    Due to the proliferative cancer rates, cardiovascular diseases, neurodegenerative disorders, autoimmune diseases and a plethora of infections across the globe, it is essential to introduce strategies that can rapidly and specifically detect the ultralow concentrations of relevant biomarkers, pathogens, toxins and pharmaceuticals in biological matrices. Considering these pathophysiologies, various research works have become necessary to fabricate biosensors for their early diagnosis and treatment, using nanomaterials like quantum dots (QDs). These nanomaterials effectively ameliorate the sensor performance with respect to their reproducibility, selectivity as well as sensitivity. In particular, graphene quantum dots (GQDs), which are ideally graphene fragments of nanometer size, constitute discrete features such as acting as attractive fluorophores and excellent electro-catalysts owing to their photo-stability, water-solubility, biocompatibility, non-toxicity and lucrativeness that make them favorable candidates for a wide range of novel biomedical applications. Herein, we reviewed about 300 biomedical studies reported over the last five years which entail the state of art as well as some pioneering ideas with respect to the prominent role of GQDs, especially in the development of optical, electrochemical and photoelectrochemical biosensors. Additionally, we outline the ideal properties of GQDs, their eclectic methods of synthesis, and the general principle behind several biosensing techniques.DFG, 428780268, Biomimetische Rezeptoren auf NanoMIP-Basis zur Virenerkennung und -entfernung mittels integrierter Ansätz

    Multi-channel SPR biosensor based on PCF for multi-analyte sensing applications

    Get PDF
    This paper presents a theoretical investigation of a novel holey fiber (Photonic Crystal Fiber (PCF)) multi-channel biosensor based on surface plasmon resonance (SPR). The large gold coated micro fluidic channels and elliptical air hole design of our proposed biosensor aided by a high refractive index over layer in two channels enables operation in two modes; multi analyte sensing and self-referencing mode. Loss spectra, dispersion and detection capability of our proposed biosensor for the two fundamental modes (HE x 11 and HE y 11 ) have been elucidated using a Finite Element Method (FEM) and Perfectly Matching Layers (PML)

    Simultaneous measurement of quality factor and wavelength shift by phase shift microcavity ring down spectroscopy

    Full text link
    Optical resonant microcavities with ultra high quality factors are widely used for biosensing. Until now, the primary method of detection has been based upon tracking the resonant wavelength shift as a function of biodetection events. One of the sources of noise in all resonant-wavelength shift measurements is the noise due to intensity fluctuations of the laser source. An alternative approach is to track the change in the quality factor of the optical cavity by using phase shift cavity ring down spectroscopy, a technique which is insensitive to the intensity fluctuations of the laser source. Here, using biotinylated microtoroid resonant cavities, we show simultaneous measurement of the quality factor and the wavelength shift by using phase shift cavity ring down spectroscopy. These measurements were performed for disassociation phase of biotin-streptavidin reaction. We found that the disassociation curves are in good agreement with the previously published results. Hence, we demonstrate not only the application of phase shift cavity ring down spectroscopy to microcavities in the liquid phase but also simultaneous measurement of the quality factor and the wavelength shift for the microcavity biosensors in the application of kinetics measurements
    corecore