2,497 research outputs found

    Local Phase Coherence Measurement for Image Analysis and Processing

    Get PDF
    The ability of humans to perceive significant pattern and structure of an image is something which humans take for granted. We can recognize objects and patterns independent of changes in image contrast and illumination. In the past decades, it has been widely recognized in both biology and computer vision that phase contains critical information in characterizing the structures in images. Despite the importance of local phase information and its significant success in many computer vision and image processing applications, the coherence behavior of local phases at scale-space is not well understood. This thesis concentrates on developing an invariant image representation method based on local phase information. In particular, considerable effort is devoted to study the coherence relationship between local phases at different scales in the vicinity of image features and to develop robust methods to measure the strength of this relationship. A computational framework that computes local phase coherence (LPC) intensity with arbitrary selections in the number of coefficients, scales, as well as the scale ratios between them has been developed. Particularly, we formulate local phase prediction as an optimization problem, where the objective function computes the closeness between true local phase and the predicted phase by LPC. The proposed framework not only facilitates flexible and reliable computation of LPC, but also broadens the potentials of LPC in many applications. We demonstrate the potentials of LPC in a number of image processing applications. Firstly, we have developed a novel sharpness assessment algorithm, identified as LPC-Sharpness Index (LPC-SI), without referencing the original image. LPC-SI is tested using four subject-rated publicly-available image databases, which demonstrates competitive performance when compared with state-of-the-art algorithms. Secondly, a new fusion quality assessment algorithm has been developed to objectively assess the performance of existing fusion algorithms. Validations over our subject-rated multi-exposure multi-focus image database show good correlations between subjective ranking score and the proposed image fusion quality index. Thirdly, the invariant properties of LPC measure have been employed to solve image registration problem where inconsistency in intensity or contrast patterns are the major challenges. LPC map has been utilized to estimate image plane transformation by maximizing weighted mutual information objective function over a range of possible transformations. Finally, the disruption of phase coherence due to blurring process is employed in a multi-focus image fusion algorithm. The algorithm utilizes two activity measures, LPC as sharpness activity measure along with local energy as contrast activity measure. We show that combining these two activity measures result in notable performance improvement in achieving both maximal contrast and maximal sharpness simultaneously at each spatial location

    Nonmechanical parfocal and autofocus features based on wave propagation distribution in lensfree holographic microscopy

    Get PDF
    Performing long-term cell observations is a non-trivial task for conventional optical microscopy, since it is usually not compatible with environments of an incubator and its temperature and humidity requirements. Lensless holographic microscopy, being entirely based on semiconductor chips without lenses and without any moving parts, has proven to be a very interesting alternative to conventional microscopy. Here, we report on the integration of a computational parfocal feature, which operates based on wave propagation distribution analysis, to perform a fast autofocusing process. This unique non-mechanical focusing approach was implemented to keep the imaged object staying in-focus during continuous long-term and real-time recordings. A light-emitting diode (LED) combined with pinhole setup was used to realize a point light source, leading to a resolution down to 2.76 ÎĽm. Our approach delivers not only in-focus sharp images of dynamic cells, but also three-dimensional (3D) information on their (x, y, z)-positions. System reliability tests were conducted inside a sealed incubator to monitor cultures of three different biological living cells (i.e., MIN6, neuroblastoma (SH-SY5Y), and Prorocentrum minimum). Altogether, this autofocusing framework enables new opportunities for highly integrated microscopic imaging and dynamic tracking of moving objects in harsh environments with large sample areas

    Monte Carlo-based Noise Compensation in Coil Intensity Corrected Endorectal MRI

    Get PDF
    Background: Prostate cancer is one of the most common forms of cancer found in males making early diagnosis important. Magnetic resonance imaging (MRI) has been useful in visualizing and localizing tumor candidates and with the use of endorectal coils (ERC), the signal-to-noise ratio (SNR) can be improved. The coils introduce intensity inhomogeneities and the surface coil intensity correction built into MRI scanners is used to reduce these inhomogeneities. However, the correction typically performed at the MRI scanner level leads to noise amplification and noise level variations. Methods: In this study, we introduce a new Monte Carlo-based noise compensation approach for coil intensity corrected endorectal MRI which allows for effective noise compensation and preservation of details within the prostate. The approach accounts for the ERC SNR profile via a spatially-adaptive noise model for correcting non-stationary noise variations. Such a method is useful particularly for improving the image quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available. Results: SNR and contrast-to-noise ratio (CNR) analysis in patient experiments demonstrate an average improvement of 11.7 dB and 11.2 dB respectively over uncorrected endorectal MRI, and provides strong performance when compared to existing approaches. Conclusions: A new noise compensation method was developed for the purpose of improving the quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level. We illustrate that promising noise compensation performance can be achieved for the proposed approach, which is particularly important for processing coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available.Comment: 23 page

    Dual modality optical coherence tomography : Technology development and biomedical applications

    Get PDF
    Optical coherence tomography (OCT) is a cross-sectional imaging modality that is widely used in clinical ophthalmology and interventional cardiology. It is highly promising for in situ characterization of tumor tissues. OCT has high spatial resolution and high imaging speed to assist clinical decision making in real-time. OCT can be used in both structural imaging and mechanical characterization. Malignant tumor tissue alters morphology. Additionally, structural OCT imaging has limited tissue differentiation capability because of the complex and noisy nature of the OCT signal. Moreover, the contrast of structural OCT signal derived from tissue’s light scattering properties has little chemical specificity. Hence, interrogating additional tissue properties using OCT would improve the outcome of OCT’s clinical applications. In addition to morphological difference, pathological tissue such as cancer breast tissue usually possesses higher stiffness compared to the normal healthy tissue, which indicates a compelling reason for the specific combination of structural OCT imaging with stiffness assessment in the development of dual-modality OCT system for the characterization of the breast cancer diagnosis. This dissertation seeks to integrate the structural OCT imaging and the optical coherence elastography (OCE) for breast cancer tissue characterization. OCE is a functional extension of OCT. OCE measures the mechanical response (deformation, resonant frequency, elastic wave propagation) of biological tissues under external or internal mechanical stimulation and extracts the mechanical properties of tissue related to its pathological and physiological processes. Conventional OCE techniques (i.e., compression, surface acoustic wave, magnetomotive OCE) measure the strain field and the results of OCE measurement are different under different loading conditions. Inconsistency is observed between OCE characterization results from different measurement sessions. Therefore, a robust mechanical characterization is required for force/stress quantification. A quantitative optical coherence elastography (qOCE) that tracks both force and displacement is proposed and developed at NJIT. qOCE instrument is based on a fiber optic probe integrated with a Fabry-Perot force sensor and the miniature probe can be delivered to arbitrary locations within animal or human body. In this dissertation, the principle of qOCE technology is described. Experimental results are acquired to demonstrate the capability of qOCE in characterizing the elasticity of biological tissue. Moreover, a handheld optical instrument is developed to allow in vivo real-time OCE characterization based on an adaptive Doppler analysis algorithm to accurately track the motion of sample under compression. For the development of the dual modality OCT system, the structural OCT images exhibit additive and multiplicative noises that degrade the image quality. To suppress noise in OCT imaging, a noise adaptive wavelet thresholding (NAWT) algorithm is developed to remove the speckle noise in OCT images. NAWT algorithm characterizes the speckle noise in the wavelet domain adaptively and removes the speckle noise while preserving the sample structure. Furthermore, a novel denoising algorithm is also developed that adaptively eliminates the additive noise from the complex OCT using Doppler variation analysis
    • …
    corecore