5,126 research outputs found
A survey of exemplar-based texture synthesis
Exemplar-based texture synthesis is the process of generating, from an input
sample, new texture images of arbitrary size and which are perceptually
equivalent to the sample. The two main approaches are statistics-based methods
and patch re-arrangement methods. In the first class, a texture is
characterized by a statistical signature; then, a random sampling conditioned
to this signature produces genuinely different texture images. The second class
boils down to a clever "copy-paste" procedure, which stitches together large
regions of the sample. Hybrid methods try to combine ideas from both approaches
to avoid their hurdles. The recent approaches using convolutional neural
networks fit to this classification, some being statistical and others
performing patch re-arrangement in the feature space. They produce impressive
synthesis on various kinds of textures. Nevertheless, we found that most real
textures are organized at multiple scales, with global structures revealed at
coarse scales and highly varying details at finer ones. Thus, when confronted
with large natural images of textures the results of state-of-the-art methods
degrade rapidly, and the problem of modeling them remains wide open.Comment: v2: Added comments and typos fixes. New section added to describe
FRAME. New method presented: CNNMR
Deep learning analysis of the myocardium in coronary CT angiography for identification of patients with functionally significant coronary artery stenosis
In patients with coronary artery stenoses of intermediate severity, the
functional significance needs to be determined. Fractional flow reserve (FFR)
measurement, performed during invasive coronary angiography (ICA), is most
often used in clinical practice. To reduce the number of ICA procedures, we
present a method for automatic identification of patients with functionally
significant coronary artery stenoses, employing deep learning analysis of the
left ventricle (LV) myocardium in rest coronary CT angiography (CCTA). The
study includes consecutively acquired CCTA scans of 166 patients with FFR
measurements. To identify patients with a functionally significant coronary
artery stenosis, analysis is performed in several stages. First, the LV
myocardium is segmented using a multiscale convolutional neural network (CNN).
To characterize the segmented LV myocardium, it is subsequently encoded using
unsupervised convolutional autoencoder (CAE). Thereafter, patients are
classified according to the presence of functionally significant stenosis using
an SVM classifier based on the extracted and clustered encodings. Quantitative
evaluation of LV myocardium segmentation in 20 images resulted in an average
Dice coefficient of 0.91 and an average mean absolute distance between the
segmented and reference LV boundaries of 0.7 mm. Classification of patients was
evaluated in the remaining 126 CCTA scans in 50 10-fold cross-validation
experiments and resulted in an area under the receiver operating characteristic
curve of 0.74 +- 0.02. At sensitivity levels 0.60, 0.70 and 0.80, the
corresponding specificity was 0.77, 0.71 and 0.59, respectively. The results
demonstrate that automatic analysis of the LV myocardium in a single CCTA scan
acquired at rest, without assessment of the anatomy of the coronary arteries,
can be used to identify patients with functionally significant coronary artery
stenosis.Comment: This paper was submitted in April 2017 and accepted in November 2017
for publication in Medical Image Analysis. Please cite as: Zreik et al.,
Medical Image Analysis, 2018, vol. 44, pp. 72-8
- …