6,089 research outputs found
Trace Element Estimation – Methods & Clinical Context
Understanding the effects of trace metals on human health is as complex as it is fascinating. As mentioned earlier, the high concentrations may prove toxic, as also, depletion in the concentration of the essential trace elements may cause various metabolic instabilities due to enzyme dysfunction. In the era of rapid industrialization and technological advances, it is imperative to watch keenly for contamination of the environment and its vital composition from heavy metal wastes emanating out of industries. Many metabolic disorders in man are accompanied by alterations in the concentration of one or more trace elements in some body fluid, especially blood serum or plasma It is thus important to update ourselves with various techniques available for such determinations, their operational aspects, advantages / disadvantages etc. More recently, element analysis from hair and nail has been stated as the best indices of such contamination and has also been discussed in this article
Experimental design of an interlaboratory study for trace metal analysis of liquid fluids
The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique
Simultaneous dual-element analyses of refractory metals in naturally occurring matrices using resonance ionization of sputtered atoms
The combination of secondary neutral mass spectrometry (SNMS) and resonance ionization spectroscopy (RIS) has been shown to be a powerful tool for the detection of low levels of elemental impurities in solids. Drawbacks of the technique have been the laser-repetition-rate-limited, low duty cycle of the analysis and the fact that RIS schemes are limited to determinations of a single element. These problems have been addressed as part of an ongoing program to explore the usefulness of RIS/SNMS instruments for the analysis of naturally occurring samples. Efficient two-color, two-photon (1+1) resonance ionization schemes were identified for Mo and for four platinum-group elements (Ru, Os, Ir, and Re). Careful selection of the ionization schemes allowed Mo or Ru to be measured simultaneously with Re, Os, or Ir, using two tunable dye lasers and an XeCl excimer laser. Resonance frequencies could be switched easily under computer control, so that all five elements can be rapidly analyzed. In situ measurements of these elements in metal grains from five meteorites were conducted. From the analyses, estimates of the precision and the detection limit of the instrument were made. The trade-off between lower detection limits and rapid multielement RIS analyses is discussed
Effect of wood aging on wine mineral composition and 87Sr/86Sr isotopic ratio
The evolution of mineral composition and wine strontium isotopic ratio 87Sr/86Sr (Sr IR) during wood aging were
investigated. A red wine was aged in stainless steel tanks with French oak staves (Quercus sessiliflora Salisb.), with three industrial
scale replicates. Sampling was carried out after 30, 60, and 90 days of aging, and the wines were evaluated in terms of general
analysis, phenolic composition, total polysaccharides, multielement composition, and Sr IR. Li, Be, Mg, Al, Sc, Ti, V, Mn, Co, Ni,
Cu, Zn, Ga, Ge, As, Rb, Sr, Y, Zr, Mo, Sb, Cs, Ba, Pr, Nd, Sm, Eu, Dy, Ho, Er, Yb, Lu, Tl, and Pb elements and 87Sr/86Sr were
determined by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) and Na, K, Ca, and Fe by flame atomic
absorption spectrometry (FAAS). Two-way ANOVA was applied to assess wood aging and time effect on Sr IR and mineral
composition. Wood aging resulted in significantly higher concentrations of Mg, V, Co, Ni, and Sr. At the end of the aging period,
wine exhibited statistically identical Sr IR compared to control. Study suggests that wood aging does not affect 87Sr/86Sr, not
precluding the use of this parameter for wine traceability purposesinfo:eu-repo/semantics/publishedVersio
NASA research objectives and roles
A chronology of airfoil development is presented in order to put the present NASA airfoil program in perspective. The impact of the NACA series airfoils is considered. Development of advanced analytical and experimental methods for the design and for the determination of the characteristics of not only single element airfoils, but of multielement airfoil combinations used in aerodynamic controls and high lift systems is emphasized along with applications
Correlating wine quality indicators to chemical and sensory measurements.
Twenty-seven commercial Californian Cabernet Sauvignon wines of different quality categories were analyzed with sensory and chemical methods. Correlations between five quality proxies-points awarded during a wine competition, wine expert scores, retail price, vintage, and wine region-were correlated to sensory attributes, volatile compounds, and elemental composition. Wine quality is a multi-faceted construct, incorporating many different layers. Depending on the quality proxy studied, significant correlations between quality and attributes, volatiles and elements were found, some of them previously reported in the literature
Propellent mass distribution metering apparatus Patent
Electronic recording system for spatial mass distribution of liquid rocket propellant droplets or vapors ejected from high velocity nozzle
Laser ablation-inductively coupled plasma mass spectrometry for the characterization of pigments in prehistoric rock art
Trace geochemistry of lunar material
The lunar samples from the Apollo 16 and 17 flights which were analyzed include soil, igneous rock, anorthositic gabbro, orange soil, subfloor basalt, and norite breccia. Up to 57 elements including majors, minors, rare earths and other trace elements were determined in the lunar samples. The analytical techniques used were spark source mass spectrometry and neutron activation analysis. The latter was done either instrumentally or with group radiochemical separations. The differences in abundances of the elements in lunar soils at the various sites are discussed. With regard to the major elements only Si is about the same at all the sites. A detailed analysis which was performed on a sample of the Allende meteorite is summarized
An Improved Version of the NASA-Lockheed Multielement Airfoil Analysis Computer Program
An improved version of the NASA-Lockheed computer program for the analysis of multielement airfoils is described. The predictions of the program are evaluated by comparison with recent experimental high lift data including lift, pitching moment, profile drag, and detailed distributions of surface pressures and boundary layer parameters. The results of the evaluation show that the contract objectives of improving program reliability and accuracy have been met
- …
