6 research outputs found

    Multimodal surface coils for low-field MR imaging

    Full text link
    Leveraging the potential of low-field Magnetic Resonance Imaging (MRI), our study introduces the multimodal surface RF coil, a design tailored to overcome the limitations of conventional coils in this context. The inherent challenges of low-field MRI, notably suboptimal signal-to-noise ratio (SNR) and the need for specialized RF coils, are effectively addressed by our novel design. The multimodal surface coil is characterized by a unique assembly of resonators, optimized for both B1 efficiency and low-frequency tuning capabilities, essential for low-field applications. This paper provides a thorough investigation of the conceptual framework, design intricacies, and bench test validation of the multimodal surface coil. Through detailed simulations and comparative analyses, we demonstrate its superior performance in terms of B1 field efficiency, outperforming conventional surface coils

    Dual-tuned Coaxial-transmission-line RF coils with Independent Tuning Capabilities for X-nuclear Metabolic MRS Imaging at Ultrahigh Magnetic Fields

    Full text link
    Information on the metabolism of tissues in both healthy and diseased states has potential for detecting tumors, neurodegeneration diseases, diabetes, and many metabolic disorders in biomedical studies. Hyperpolarized carbon-13 magnetic resonance imaging (13C-HPMRI) and deuterium metabolic imaging (2H-DMI) are two emerging X-nuclei used as practical imaging tools to investigate tissue metabolism. However due to their low gyromagnetic ratios (γ13C\gamma_{13C} = 10.7 MHz/T; γ2H\gamma_{2H} = 6.5 MHz/T) and natural abundance, such method required the use of a sophisticated dual-tuned radio frequency (RF) coil where the X-nucleus signal is associated with the proton signal used for anatomical reference. Here, we report a dual-tuned coaxial transmission line (CTL) RF coil agile for metabolite information operating at 7T with independent tuning capability. Analysis based on full-wave simulation has demonstrated how both resonant frequencies can be individually controlled by simply varying the constituent of the design parameters. A broadband tuning range capability is obtained, covering most of the X-nucleus signal, especially the 13C and 2H spectra at 7T. Numerical results has demonstrated the effectiveness of the magnetic field produced by the proposed dual-tuned 1H/13C and 1H/2H CTLs RF coils. Furthermore, in order to validate the feasibility of the proposed design, both dual-tuned CTLs prototypes are designed and fabricated using a semi-flexible RG-405 .086" coaxial cable and bench test results (scattering parameters and magnetic field efficiency/distributions) are successfully obtained.Comment: 9 pages, 7 figure

    Double Cross Magnetic Wall Decoupling for Quadrature Transceiver RF Array Coils using Common-Mode Differential-mode Resonators

    Full text link
    In contrast to linearly polarized RF coil arrays, quadrature transceiver coil arrays are capable of improving signal-to-noise ratio (SNR), spatial resolution and parallel imaging performance. Owing to a reduced excitation power, low specific absorption rate can be also obtained using quadrature RF coils. However, due to the complex nature of their structure and their electromagnetic proprieties, it is challenging to achieve sufficient electromagnetic decoupling while designing multichannel quadrature RF coil arrays, particularly at ultrahigh fields. In this work, we proposed a double cross magnetic wall decoupling for quadrature transceiver RF arrays and implemented the decoupling method on common-mode differential mode quadrature (CMDM) quadrature transceiver arrays at ultrahigh field of 7T. The proposed magnetic decoupling wall comprised of two intrinsic decoupled loops is used to reduce the mutual coupling between all the multi-mode current present in the quadrature CMDM array. The decoupling network has no physical connection with the CMDMs' coils giving leverage over size adjustable RF arrays. In order to validate the feasibility of the proposed cross magnetic decoupling wall, systematic studies on the decoupling performance based on the impedance of two intrinsic loops are numerically performed. A pair of quadrature transceiver CMDMs is constructed along with the proposed decoupling network and their scattering matrix is characterized using a network analyzer. The measured results show all the current modes coupling are concurrently suppressed using the proposed cross magnetic wall. Moreover, field distribution, and SNR intensity are numerically obtained for a well-decoupled 8-channel quadrature knee-coil array.Comment: 9 pages, 10 Figure

    Hairpin RF Resonators for Transceiver Arrays with High Inter-channel Isolation and B1 Efficiency at Ultrahigh Field 7T MR Imaging

    Full text link
    Electromagnetic decoupling among a close-fitting or high-density transceiver RF array elements is required to maintain the integrity of the magnetic flux density from individual channel for enhanced performance in detection sensitivity and parallel imaging. High-impedance RF coils have demonstrated to be a prominent design method to circumvent these coupling issues. Yet, inherent characteristics of these coils have ramification on the B1 field efficiency and SNR. In this work, we propose a hairpin high impedance RF resonator design for highly decoupled multichannel transceiver arrays at ultrahigh magnetic fields. Due to the high impedance property of the hairpin resonators, the proposed transceiver array can provide high decoupling performance without using any dedicated decoupling circuit among the resonant elements. Because of elimination of lumped inductors in the resonator circuit, higher B1 field efficiency in imaging subjects can be expected. In order to validate the feasibility of the proposed hairpin RF coils, systematical studies on decoupling performance, field distribution, and SNR are performed, and the results are compared with those obtained from existing high-impedance RF coil, e.g., "self-decoupled RF coil". To further investigate its performance, an 8-channel head coil array using the proposed hairpin resonators loaded with a cylindrical phantom is designed, demonstrating a 19 % increase of the B1+ field intensity compared to the "self-decoupled" coils at 7T. Furthermore, the characteristics of the hairpin RF coils are evaluated using a more realistic human head voxel model numerically. The proposed hairpin RF coil provides excellent decoupling performance and superior RF magnetic field efficiency compared to the self-decoupled high impedance coils. Bench test of a pair of fabricated hairpin coils prove to be in good accordance with numerical results.Comment: 10 pages, 12 figures, 2 tables. Second version: Add bench test results and One dimensional profile of the simulated B1

    Electric Field and SAR Reduction in High Impedance RF Arrays by Using High Permittivity Materials for 7T MR Imaging

    Full text link
    Higher frequencies and shorter wavelengths present significant design issues at ultra-high fields, making multi-channel array setup a critical component for ultra-high field MR imaging. The requirement for multi-channel arrays, as well as ongoing efforts to increase the number of channels in an array, are always limited by the major issue known as inter-element coupling. This coupling affects the current and field distribution, noise correlation between channels, and frequency of array elements, lowering imaging quality and performance. To realize the full potential of UHF MRI, we must ensure that the coupling between array elements is kept to a minimum. High-impedance coils allow array systems to completely realize their potential by providing optimal isolation while requiring minimal design modifications. These minor design changes, which demand the use of low capacitance on the conventional loop to induce elevated impedance, result in a significant safety hazard that cannot be overlooked. High electric fields are formed across these low capacitance lumped elements, which may result in higher SAR values in the imaging subject, depositing more power and, ultimately, providing a greater risk of tissue heating-related injury to the human sample. We propose an innovative method of utilizing high-dielectric material to effectively reduce electric fields and SAR values in the imaging sample while preserving the B1 efficiency and inter-element decoupling between the array elements to address this important safety concern with minimal changes to the existing array design comprising high-impedance coils.Comment: 12 pages, 18 figures, 2 table

    The UTE and ZTE Sequences at Ultra-High Magnetic Field Strengths: A Survey

    Full text link
    UTE (Ultrashort Echo Time) and ZTE (Zero Echo Time) sequences have been developed to detect short T2 relaxation signals coming from regions that are unable to be detected by conventional MRI methods. Due to the high dipole-dipole interactions in solid and semi-solid tissues, the echo time generated is simply not enough to produce a signal using conventional imaging method, often leading to void signal coming from the discussed areas. By the application of these techniques, solid and semi-solid areas can be imaged which can have a profound impact in clinical imaging. High and Ultra-high field strength (UHF) provides a vital advantage in providing better sensitivity and specificity of MR imaging. When coupled with the UTE and ZTE sequences, the image can recover void signals as well as a much-improved signal quality. To further this strategy, secondary data from various research tools was obtained to further validate the research while addressing the drawbacks to this approach. It was found that UTE and ZTE sequences coupled with some techniques such as qualitative imaging and new trajectories are very crucial for accurate image depiction of the areas of the musculoskeletal system, neural system, lung imaging and dental imaging
    corecore