7 research outputs found

    BER evaluation of post-meter PLC services in CENELEC-C band

    Get PDF
    Low voltage, in-home power-line communications (PLC) networks allow direct communication between smart meters (SM) and in-home devices (IHD). In order to minimize security issues, in many deployment scenarios transmission takes place only towards the IHD to display consumption data, with no backwards channel. As a result, channel estimation is difficult and it is necessary to use robust transmission techniques to mitigate the effect of the impulsive noise within the PLC channel. Performance of such system must be evaluated by taking into account realistic interference and channel models for a broad range of configurations. In this work we focus on performance in terms of bit error rate (BER) of a narrowband PLC (NB-PLC) operating in the CENELEC-C band (125โ€“140 kHz) taking into account realistic noise models. Our system is based on binary phase shift keying (BPSK) and quadrature phase shift keying (QPSK) modulation

    Theoretical postulation of PLC channel model

    Get PDF
    The objective of this document is to supply atheoretical basis for modelling the communicationlinks over powerlines. A comprehensive summary oftransmission properties and the noise scenario onpublic mains supply when used for data transmissionare given.Different PLC models - PLC channel, noise inPLC channel, coupling units, filters and conditioningdevices โ€“ will be created and they will be used tosimulate the PLC channel.PLC applications will have to work at veryunusual channels, solely designed for optimalelectrical power transportation, completelydisregarding signal transmission at high frequencies.It is shown that the typical properties aredescribed by transfer functions and noise scenariostypical for access and inhouse networks. The generaltransfer function for different channel types is derivedand, since an emulation system should reproducetypical classes of channels rather than singlemeasurements, the transfer function is concretisedwith reference channels. These are later serving asbasis for development of channel simulators andchannel emulators. Special attention is paid tomodelling of aperiodic impulsive noise since PLCsystems are reacting very sensitive to them and thisclass of noise has been insufficiently considered so far

    OFDM Receiver Performance with Measured Channel Model in Power Line Communications

    Get PDF
    ๋ณธ ๋…ผ๋ฌธ์—์„œ๋Š” ํ™ˆ ๋„คํŠธ์›Œํฌ์˜ ์ค‘์š”ํ•œ ๊ตฌ์„ฑ ์š”์†Œ์ธ ์ „๋ ฅ์„  ํ†ต์‹ ์„ ์œ„ํ•œ ์ฑ„๋„ ์ธก์ • ๋ฐฉ๋ฒ•์„ ์†Œ๊ฐœํ•˜๊ณ  ์ธก์ •๋œ ์ฑ„๋„์„ ๊ธฐ๋ฐ˜์œผ๋กœ ํ•˜๋Š” ์ „๋ ฅ์„  ์‹œ์Šคํ…œ์˜ ์„ฑ๋Šฅ ๋ถ„์„์„ ์ˆ˜ํ–‰ํ•œ๋‹ค. ๋จผ์ € ์ „๋ ฅ์„  ํ†ต์‹ ์˜ ํ‘œ์ค€ํ™” ๋™ํ–ฅ์„ ์‚ดํŽด๋ณด๊ณ , ๋‹ค์Œ์œผ๋กœ ์ „๋ ฅ์„  ์ฑ„๋„์„ ์ธก์ •ํ•˜๊ธฐ ์œ„ํ•œ ๋ฐฉ๋ฒ•์„ ์†Œ๊ฐœํ•œ ํ›„, ์ „๋ ฅ์„  ์ฑ„๋„ ๋ชจ๋ธ์„ ์ œ์‹œํ•œ๋‹ค. ์ธก์ •๋œ ์ฑ„๋„์„ ๊ธฐ๋ฐ˜์œผ๋กœ OFDM ๋ฐฉ์‹์˜ HomePlug 1.0 ํ‘œ์ค€๊ณผ ์ „์†ก ์†๋„ ํ–ฅ์ƒ์„ ์œ„ํ•ด ์ œ์•ˆ๋œ ์ „์†ก ๊ธฐ์ˆ ์˜ ์„ฑ๋Šฅ์„ ๋ถ„์„ํ•œ๋‹ค. ์ด๋Ÿฌํ•œ ๊ธฐ์ˆ ๋“ค์€ ์ „๋ ฅ์„  ํ†ต์‹ ์„ ์œ„ํ•œ ํ‘œ์ค€์— ์ ์šฉ๋˜์–ด ์ „๋ ฅ์„  ํ†ต์‹  ์šฉ๋Ÿ‰ ์ฆ๋Œ€ ๋ฐ ์ปค๋ฒ„๋ฆฌ์ง€ ํ™•๋Œ€์— ๊ธฐ์—ฌํ•  ๊ฒƒ์œผ๋กœ ์˜ˆ์ƒ๋œ๋‹ค.This paper reports the results of wideband channel measurements conducted on in house outlets. Two kinds of channel measurements were performed: impulse response measurements and noise signal measurements. In measure based channel model, preamble assisted orthogonal frequency-division multiplexing access (OFDM) receiver scheme is proposed for differential phase shift keying (DPSK) and quadrature amplitude modulation (QAM). Timing synchronization and channel estimation is performed using the preamble. We provide numerical results to illustrate the performance of OFDM receiver in measure based channel model.๋Œ€ํ•™ IT์—ฐ๊ตฌ์„ผํ„ฐ ์œก์„ฑ, ์ง€์›์‚ฌ

    Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

    Get PDF
    The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology

    Timed power line data communication

    Get PDF
    With the ever increasing demand for data communication methods, power line communication has become an interesting alternative method for data communication. Power line communication falls into two categories: one for data transmission between sites in the power grid and the other for home or office networking. When considering home or office networking, existing methods are either too slow for tasks other than simple automation, or are very fast with a higher cost than necessary for the desired function. The objective in this work is to develop a lower cost communication system with an intermediate data transmission rate.At first glance, power line communication looks like a good option because of the availability of power outlets in every room of a building. However, the power conductors were installed solely for the purpose of distributing 60 Hz mains power and, for data signals, they exhibit very high attenuation, variable impedance and there is radio frequency shielding. Furthermore, many of the 60 Hz loads produce radio frequency interference that impedes data communication. Previous research has shown that much of the noise is time synchronous with the 60 Hz mains frequency and that the majority of data errors occur during these periods of high noise. This work develops a power line communication protocol that coordinates transmissions and uses only the predictable times of lower noise. Using a central control strategy, the power line 60 Hz mains signal is divided into 16 timeslots and each timeslot is monitored for errors. The central controller periodically polls all stations to learn which timeslots have low noise and it then controls all transmissions to make the best use of these good timeslots. The periodic polling allows the system to adapt to changes in electrical loading and noise. This control strategy has been achieved with modest complexity and laboratory measurements have shown throughput approaching 70% of the modem bit rate

    Electromagnetic compatibility of power line communication systems

    Get PDF
    The power system has been used for communication purposes for many decades, although it was mainly the power utility companies that used low bit rates for control and monitoring purposes. In the last ten years, however, the deregulation of the power and telecommunication markets has spurred the idea of using and commercializing the power networks for a range of new communication applications and services. The idea has been developed and implemented into both, narrowband and broadband systems, which are defined in terms of the operation frequency band. Depending on the frequency band, the systems over powerlines can be: Narrow-band. They use frequencies ranging from 3-148.5 kHz in Europe, with the upper frequency extending up to 500 kHz in the United States and Japan. In Europe, this frequency range is standardized by CENELEC Standard EN 50065. Broadband. The used frequency range is 1-30MHz; 1-15MHz for outdoor systems and 15-30MHz for indoor systems. In this frequency range, the standardization situation is still unclear and there exist no regulations. The developed applications and systems use different parts of the power network: medium voltage (MV) and low voltage (LV) cabling for outdoor applications and building cabling for indoor applications. These cables are designed and optimized for power transmission at frequencies of 50/60Hz and represent a hostile medium for transmissions at higher frequencies. This thesis concentrates on electromagnetic compatibility (EMC) aspects and some optimization issues of the broadband systems, currently known as Powerline Communications (PLC) or Broadband Power Line (BPL). The work presented here was preformed in the framework of the European project OPERA (http://www.ist-opera.org/). A short description of the project is given in Chapter 1. The second chapter presents the basis, introduction, description and state of the art of the topics of interest for this thesis. That chapter is divided into three parts. Each of these parts starts with a short introduction to the topic to be addressed. The introductions are intended for those not familiar with the topic at hand and they can be skipped by those already knowledgeable of it. The first part of Chapter 2 gives an overview and introduction to telecommunication issues relevant to the thesis, as well as the general technical specifications of the OPERA system. The second part deals with the transmission medium which, for the case of PLC, is the power system. The fundamentals and the different components of the PLC system are given there and the state of the art regarding the transmission channel is presented. The third part deals with the EMC and standardization issues related to the technology. The main contributions of the thesis are presented in chapters 3 to 7. The PLC technology distinguishes itself from other technologies in that it uses already existing, ubiquitous wiring, so that no new infrastructure is needed. On the other hand, using a channel designed originally for other purposes means that it is not optimized for the frequencies and applications of interest for broadband transmission. If PLC is to compete with other technologies, these problems have to be well understood and solved, so that the system can be optimized by taking into account the parameters and constrains of the already existing medium. Although the PLC system is being improved continuously, there are still concerns about emissions, immunity and standardization. These issues are important since PLC operates in an environment already populated by other services at the same frequencies, so that fair co-existence is needed. Moreover, the PLC modem has a combined mains and telecom port and, as a consequence, the standards for conducted emissions from those two types of ports are not directly applicable. In addition, the symmetry of the cables used is low and, therefore, emissions are higher than, for example, emissions from twisted pair cables used in xDSL. A good understanding of emissions and immunity in PLC systems is therefore of great importance for the optimization of the system and for EMC standardization to be based on objective technical criteria. Even if the basic phenomena are essentially the same as for any other wire transmission system, the complexity and variability of the topologies of existing structures is so large that simple, straightforward solutions are often not applicable. Emissions from the cabling are primarily due to the common mode signals. Part of the energy in this mode is injected by the imperfectly balanced output stages of the PLC modems themselves. In addition, the common mode appears at punctual imbalanced discontinuities and distributed asymmetry along the PLC signal path in the power cables. Chapter 3 presents the work performed to improve our understanding of the sources of the common-mode current and the parameters that influence its behavior, including related measurements and simulations. For the purpose of this study, a model house was built at the EPFL's test site. Different cablings were used to study the influence of different parameters on the behavior of the common-mode current since it is the main source for both types of emissions, conducted and radiated ones. The influence of different parameters such as the cable terminations, the symmetry of the termination, the height of the conductors above the ground, the presence of power outlets, switches, empty and occupied sockets and the topology, are analyzed. The data are also used to test two methods used to simulate the differential-to-common-mode conversion and the conducted emissions, namely the transmission line model and the full wave approach provided by the Method of Moments through the Numerical Electromagnetic Code (NEC). In Chapter 4, problems related to PLC immunity testing are treated. We show that the conversion of the differential mode to the common mode is coupled with the reverse conversion by reciprocity. Due to the low symmetry of PLC cabling, part of the injected common mode test signal is converted into a differential mode signal that interferes with the wanted signal at the input of the modem being tested. Depending on the actual symmetry of the Coupling-Decoupling Network (CDN), not specified in the standards, the immunity test may yield erroneous results due to the effect of this differential mode component. Working under the assumption that the CDN is built to exhibit a symmetry similar to that of PLC networks as inferred from its longitudinal conversion loss, we estimate the differential mode disturbance level that the modems should withstand from a narrowband interferer. The bit error rate induced by the presence of the disturbing differential mode current from the CDN is also estimated, for a total physical channel transmission rate of 200 Mbps, to be of the order of 1ร—10-5 to 5ร—10-5. Since these rates can be handled by error correcting coding and MAC ARQ procedures, it is concluded that the modems are not likely to suffer any severe performance degradation due to immunity testing if the CDN exhibits a symmetry similar to that of PLC networks. Simulating the complete PLC network or any significant part of it using numerical techniques such as the method of moments proves to be of limited practical use due to the fact that PLC networks extend over many wavelengths. The transmission line approximation, on the other hand, although more efficient and sufficiently accurate for differential mode calculations, is not directly applicable to simulate the EMC behavior since it neglects the antenna-mode currents that are significant contributors to the radiated emissions. Chapter 5 presents a novel approach to evaluate the antenna-mode currents using a modified transmission line theory, thus making this numerically efficient technique applicable to the estimation of emissions in PLC. An integral equation describing the antenna-mode currents along a two-wire transmission line is derived. It is further shown that, when the line cross-sectional dimensions are electrically small, the integral equation reduces to a pair of transmission line-like equations with equivalent line parameters (per-unit-length inductance and capacitance). The derived equations make it possible to compute the antenna mode currents using a traditional transmission line code with appropriate parameters. The derived equations are tested versus numerical results obtained using NEC and reasonably good agreement is found. Another important EMC issue related to PLC is the mitigation of emissions. Chapter 6 describes a technique that has been proposed to achieve a reduction of emissions associated with indoor PLC networks through the introduction of a 180ยฐ out-of-phase replica of the PLC signal into the unused neutral-ground circuit. A modification to this technique is proposed based on the selection of the appropriate amplitude and phase of the auxiliary signal, allowing a higher degree of field attenuation. A way of implementing this technique is proposed and studied, namely the integration of a required antenna into the PLC modems themselves. The measured fields very close to the modem allow the determination of the magnitude and phase of the compensation voltage. The proposed implementation should be used only to handle customer complaints, when emissions should be lowered at locations where PLC signals might cause unwanted interference or when additional capacity is required and it can be obtained through the gained signal to noise margin. Although, in principle, due to nonalignment of the wanted and the compensation field directions, minimizing one component of the field may result in an increase of the other components, we show that the application of the technique results in an overall average reduction of 10-20 dB of all the field components in the region of interest. In the same Chapter 6, we address the more general issue of the application of mitigation techniques' gained emissions margin to increase the overall throughput of PLC systems. We show that an increase in the signal power (made possible by the inclusion of mitigation techniques) leads to a considerable increase in the PLC channel capacity. Using a number of simplifications, we show that the capacity of the channel can indeed be increased by up to 66 Mbps for mitigation efficiencies of only 10 dB. We also present the results of laboratory measurements aimed at studying, under controlled conditions, different characteristics of notching in OPERA PLC modems, such as total and effective notch width, notch depth, maximum notch depth, etc. These measurements show that it is possible to obtain attenuations of up to about 45 dB for notches in all frequency bands, 10MHz, 20MHz and 30MHz. What differs for these three bands is the minimum number of carriers that need to be notched to obtain that maximum attenuation. This is an important point, since, to implement notches that have the required depth and width, one must know how many subcarriers to suppress and how deep these need to be reduced. High density PLC deployment requires the increase of overall system data rate. To achieve the higher data rates, frequency reuse in these systems is needed. In Chapter 7, we present the idea for using so-called blocking filters as a possible solution for a frequency reuse. Experimental data obtained on a real distribution network show that the use of blocking filters can, in certain cases, ensure high enough RF separation of the LV feeders belonging to the same substation. In some cases, even with the possibility to design and integrate effective blocking filters, the system needs to provide additional synchronization mechanisms for frequency reuse
    corecore