31,469 research outputs found
Ultrafast High-pressure AC Electro-osmotic Pumps for Portable Biomedical Microfluidics
This paper details the development of an integrated AC electro-osmotic (ACEO)
microfluidic pump for dilute electrolytes consisting of a long serpentine
microchannel lined with three dimensional (3D) stepped electrode arrays. Using
low AC voltage (1 Volt rms, 1 kHz), power (5 mW) and current (3.5 mA) in water,
the pump is capable of generating a 1.4 kPa head pressure, a 100-fold increase
over prior ACEO pumps, and a 1.37 mm/sec effective slip velocity over the
electrodes without flow reversal. The integrated ACEO pump can utilize low
ionic strength solutions such as distilled water as the working solution to
pump physiological strength (100 mM) biological solutions in separate
microfluidic devices, with potential applications in portable or implantable
biomedical microfluidic devices. As a proof-of-concept experiment, the use of
the ACEO pumps for DNA hybridization in a microfluidic microarray is
demonstrated
Simplified immobilisation method for histidine-tagged enzymes in poly(methyl methacrylate) microfluidic devices
Article in press. Kulsharova, G., New BIOTECHNOLOGY (2017), https://doi.org/10.1016/j.nbt.2017.12.004Poly(methyl methacrylate) (PMMA) microfluidic devices have become promising platforms for a wide range of applications. Here we report a simple method for immobilising histidine-tagged enzymes suitable for PMMA microfluidic devices. The 1-step-immobilisation described is based on the affinity of the His-tag/Ni-NTA interaction and does not require prior amination of the PMMA surface, unlike many existing protocols. We compared it with a 3-step immobilisation protocol involving amination of PMMA and linking NTA via a glutaraldehyde cross-linker. These methods were applied to immobilise transketolase (TK) in PMMA microfluidic devices. Binding efficiency studies showed that about 15% of the supplied TK was bound using the 1-step method and about 26% of the enzyme was bound by the 3-step method. However, the TK-catalysed reaction producing l-erythrulose performed in microfluidic devices showed that specific activity of TK in the device utilising the 1-step immobilisation method was approximately 30% higher than that of its counterpart. Reusability of the microfluidic device produced via the 1-step method was tested for three cycles of enzymatic reaction and at least 85% of the initial productivity was maintained. The device could be operated for up to 40 h in a continuous flow and on average 70% of the initial productivity was maintained. The simplified immobilisation method required fewer chemicals and less time for preparation of the immobilised microfluidic device compared to the 3-step method while achieving higher specific enzyme activity. The method represents a promising approach for the development of immobilised enzymatic microfluidic devices and could potentially be applied to combine protein purification with immobilisation.Peer reviewe
Recommended from our members
Using printer ink color to control the behavior of paper microfluidics.
Paper microfluidic devices (including lateral flow assays) offer an excellent combination of utility and low cost. Many paper microfluidic devices are fabricated using the Xerox ColorQube line of commercial wax-based color printers; the wax ink serves as a hydrophobic barrier to fluid flow. These printers are capable of depositing four different colors of ink, cyan (C), magenta (M), yellow (Y), and black (K), plus 11 combinations of these colors (CM, CY, CK, MY, MK, YK, CMY, CMK, CYK, MYK, and CMYK), although most researchers use only black ink to print paper microfluidic devices. Recently, as part of a project to develop a computer-aided design framework for use with paper microfluidics devices, we unexpectedly observed that different colors of wax ink behave differently in paper microfluidics. We found that among the single colors of ink, black ink actually had the most barrier failures, and magenta ink had the fewest barrier failures. In addition, some combinations of colors performed even better than magenta: the combinations CY, MK, YK, CMY, CYK and MYK had no barrier failures in our study. We also found that the printer delivers significantly different amounts of ink to the paper for the different color combinations, and in general, the color combinations that formed the strongest barriers to fluid flow were the ones that had the most ink delivered to the paper. This suggests that by simply weighing paper samples printed with all 15 combinations of colors, one can easily find the color combinations most likely to form a strong barrier for a given printer. Finally, to show that deliberate choices of ink colors can actually be used to create new functions in paper microfluidics, we designed and tested a new color-based "antifuse" structure that protects paper microfluidic devices from a typical operator error (addition of too much fluid to the device). Our results provide a set of color choice guidelines that designers can use to control the behavior of their paper microfluidics
Self-partitioning SlipChip for slip-induced droplet formation and human papillomavirus viral load quantification with digital LAMP
Human papillomavirus (HPV) is one of the most common sexually transmitted infections worldwide, and persistent HPV infection can cause warts and even cancer. Nucleic acid analysis of HPV viral DNA can be very informative for the diagnosis and monitoring of HPV. Digital nucleic acid analysis, such as digital PCR and digital isothermal amplification, can provide sensitive detection and precise quantification of target nucleic acids, and its utility has been demonstrated in many biological research and medical diagnostic applications. A variety of methods have been developed for the generation of a large number of individual reaction partitions, a key requirement for digital nucleic acid analysis. However, an easily assembled and operated device for robust droplet formation without preprocessing devices, auxiliary instrumentation or control systems is still highly desired. In this paper, we present a self-partitioning SlipChip (sp-SlipChip) microfluidic device for the slip-induced generation of droplets to perform digital loop-mediated isothermal amplification (LAMP) for the detection and quantification of HPV DNA. In contrast to traditional SlipChip methods, which require the precise alignment of microfeatures, this sp-SlipChip utilized a design of “chain-of-pearls” continuous microfluidic channel that is independent of the overlapping of microfeatures on different plates to establish the fluidic path for reagent loading. Initiated by a simple slipping step, the aqueous solution can robustly self-partition into individual droplets by capillary pressure-driven flow. This advantage makes the sp-SlipChip very appealing for the point-of-care quantitative analysis of viral load. As a proof of concept, we performed digital LAMP on an sp-SlipChip to quantify human papillomaviruses (HPVs) 16 and 18 and tested this method with fifteen anonymous clinical samples
An Ultrahigh-throughput Microfluidic Platform for Single-cell Genome Sequencing.
Sequencing technologies have undergone a paradigm shift from bulk to single-cell resolution in response to an evolving understanding of the role of cellular heterogeneity in biological systems. However, single-cell sequencing of large populations has been hampered by limitations in processing genomes for sequencing. In this paper, we describe a method for single-cell genome sequencing (SiC-seq) which uses droplet microfluidics to isolate, amplify, and barcode the genomes of single cells. Cell encapsulation in microgels allows the compartmentalized purification and tagmentation of DNA, while a microfluidic merger efficiently pairs each genome with a unique single-cell oligonucleotide barcode, allowing >50,000 single cells to be sequenced per run. The sequencing data is demultiplexed by barcode, generating groups of reads originating from single cells. As a high-throughput and low-bias method of single-cell sequencing, SiC-seq will enable a broader range of genomic studies targeted at diverse cell populations
Reusable Ionogel-based Photo-actuators in a Lab-on-a-disc
This paper describes the design, fabrication and performance of a reusable ionogel-based photo-actuator, in-situ photopolymerised into a lab-on-a-disc microfluidic device, for flow control. The ionogel provides an effective barrier to liquids during storage of reagents and spinning of the disc. A simple LED (white light) triggers actuation of the ionogel for selective and precise channel opening at a desired location and time. The mechanism of actuation is reversible, and regeneration of the actuator is possible with an acid chloride solution. In order to achieve regeneration, the Lab-on-a-Disc device was designed with a microchannel connected perpendicularly to the bottom of the ionogel actuator (regeneration channel). This configuration allows the acid solution to reach the actuator, independently from the main channel, which initiates ionogel swelling and main channel closure, and thereby enables reusability of the whole device.Economía y Competitividad), Spain. This project has receivedfunding from the European Union Seventh Framework Programme(FP7) for Research, Technological Development and Demonstrationunder grant agreement no. 604241. JS and FBL acknowledge fund-ing support from Gobierno de Espa˜na, Ministerio de Economía yCompetitividad, with Grant No. BIO2016-80417-P and personallyacknowledge to Marian M. De Pancorbo for letting them to use herlaboratory facilities at UPV/EHU. A.T., L.F., and D.D. are grateful forfinancial support from the Marie Curie Innovative Training Net-work OrgBIO (Marie Curie ITN, GA607896) and Science FoundationIreland (SFI) under the Insight Centre for Data Analytics initiative,Grant Number SFI/12/RC/2289
Simvastatin Rapidly and Reversibly Inhibits Insulin Secretion in Intact Single-Islet Cultures
open10Epidemiological studies suggest that statins may promote the development or exacerbation of diabetes, but whether this occurs through inhibition of insulin secretion is unclear. This lack of understanding is partly due to the cellular models used to explore this phenomenon (cell lines or pooled islets), which are non-physiologic and have limited clinical transferability.openScattolini, Valentina; Luni, Camilla; Zambon, Alessandro; Galvanin, Silvia; Gagliano, Onelia; Ciubotaru, Catalin Dacian; Avogaro, Angelo; Mammano, Fabio; Elvassore, Nicola; Fadini, Gian PaoloScattolini, Valentina; Luni, Camilla; Zambon, Alessandro; Galvanin, Silvia; Gagliano, Onelia; Ciubotaru, CATALIN DACIAN; Avogaro, Angelo; Mammano, Fabio; Elvassore, Nicola; Fadini, GIAN PAOL
Molecular biology on a microfluidic chip
We have developed microfluidic chips for automating molecular biology processes such as gene ligation and gene transformation from nanolitre sample volumes with parallel architecture. Unlike conventional tube methods with cumbersome pipetting procedures, all processes, including metering of samples, ligation and transformation, were carried out in the microfluidic chips through pneumatic control of the nanofluid. The microfluidic devices presented here offer an illustration of some of the basic physics that arises when trying to miniaturize and automate biological techniques
- …
